Your browser doesn't support javascript.
loading
High-sensitivity capillary electrophoresis determination of inorganic anions in serum and urine using on-line preconcentration by transient isotachophoresis.
Hirokawa, Takeshi; Yoshioka, Masato; Okamoto, Hikaru; Timerbaev, Andrei R; Blaschke, Gottfried.
Afiliación
  • Hirokawa T; Department of Applied Chemistry, Graduate School of Engineering, Hiroshima University, 1-4-1 Kagamiyama 1, Higashi-Hiroshima 739-8527, Japan. hiro77@hiroshima-u.ac.jp
Article en En | MEDLINE | ID: mdl-15522716
ABSTRACT
Concentrations of inorganic anions, both as individual species and biotransformation products, in physiological fluids are of strong concern in clinical studies. To date, analytical methodologies have either required different analytical procedures to determine these analytes in plasma and urine, or extensive sample preparation, or unconventional and often expensive detection schemes, or both. A simple and sensitive capillary electrophoresis (CE) method with direct UV detection was developed for the simultaneous determination of iodide, bromide and nitrate in human plasma and urine, with a special focus on reliable quantification of the trace serum iodide. With the latter objective, the method incorporates a transient isotachophoresis (tITP) procedure enabling an efficient on-line preconcentration of iodide (limit of detection, 1.4 microg l(-1)) as well as other moderately mobile analytes that fall into the tITP range. The analyses of both types of biofluids were performed using an acidic electrolyte system composed of 0.25 mol l(-1) sodium chloride and 7.5 mmol l(-1) cetyltrimethylammonium chloride at pH 2.2 and 0.5 mol l(-1) 2-(N-morpholino)ethanesulfonate (pH 6.0) as terminating electrolyte. Relative standard deviations (R.S.D.) below 3.0% and 9.2% were obtained for within-day and between-day precision, respectively. Resolution and quantification of oxalic acid was also feasible under optimized tITP-CE conditions. Sample preparation required only ultrafiltration (serum) and dilution (urine). A number of plasma and urine samples were evaluated with this assay and the iodide, bromide and nitrate concentrations were in the expected clinical concentration ranges.
Asunto(s)
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Electroforesis Capilar / Electroforesis / Compuestos Inorgánicos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Año: 2004 Tipo del documento: Article
Buscar en Google
Banco de datos: MEDLINE Asunto principal: Electroforesis Capilar / Electroforesis / Compuestos Inorgánicos Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Año: 2004 Tipo del documento: Article