Your browser doesn't support javascript.
loading
Diagnostic accuracy of interferon gamma-induced protein 10 for tuberculosis: a meta-analysis.
Guo, Shu-Jin; Jia, Liu-Qun; Hu, Qian-Jing; Long, Hong-Yu; Pang, Cai-Shuang; Wen, Fu-Qiang.
Afiliación
  • Guo SJ; Division of Pulmonary Diseases, State Key Laboratory of Biotherapy of China and Department of Respiratory Medicine, West China Hospital of Sichuan University Chengdu 610041, China.
  • Jia LQ; Division of Pulmonary Diseases, State Key Laboratory of Biotherapy of China and Department of Respiratory Medicine, West China Hospital of Sichuan University Chengdu 610041, China.
  • Hu QJ; Division of Pulmonary Diseases, State Key Laboratory of Biotherapy of China and Department of Respiratory Medicine, West China Hospital of Sichuan University Chengdu 610041, China.
  • Long HY; Division of Pulmonary Diseases, State Key Laboratory of Biotherapy of China and Department of Respiratory Medicine, West China Hospital of Sichuan University Chengdu 610041, China.
  • Pang CS; Division of Pulmonary Diseases, State Key Laboratory of Biotherapy of China and Department of Respiratory Medicine, West China Hospital of Sichuan University Chengdu 610041, China.
  • Wen FQ; Division of Pulmonary Diseases, State Key Laboratory of Biotherapy of China and Department of Respiratory Medicine, West China Hospital of Sichuan University Chengdu 610041, China.
Int J Clin Exp Med ; 7(1): 93-100, 2014.
Article en En | MEDLINE | ID: mdl-24482693
ABSTRACT
The diagnostic accuracy of tuberculosis (TB) remains a clinical challenge, and a number of studies have used the interferon gamma-induced protein 10 (IP-10) in the diagnosis of TB. The aim of the present meta-analysis was to determine the overall accuracy of IP-10 in the diagnosis of TB. A systematic review of studies published in English from Medline, Embase and Cochrane Library was conducted and the data concerning the accuracy of IP-10 in the diagnosis of TB were pooled. The methodological quality of each study was assessed by QUADAS (quality assessment for studies of diagnostic accuracy). Statistical analysis was performed by employing Meta-Disc 1.4 soft-ware and STATA. The overall test performance was summarized using receiver operating characteristic curves. 14 studies, based on 2075 subjects, met the inclusion criteria. The summary estimates for IP-10 in the diagnosis of TB were sensitivity 0.73 (95% CI, 0.71-0.76), specificity 0.83 (95% CI, 0.81-0.86), positive likelihood ratio 7.08 (95% CI, 3.94-12.72), negative likelihood ratio 0.26 (95% CI, 0.20-0.35) and diagnostic odds ratio 29.50 (95% CI, 14.43-60.30), and the area under the curve was 0.88. Our findings suggest that IP-10 may improve the accuracy of TB diagnosis, while the results of IP-10 assays should be interpreted in parallel with conventional test results and other clinical findings.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Prognostic_studies / Systematic_reviews Idioma: En Año: 2014 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Prognostic_studies / Systematic_reviews Idioma: En Año: 2014 Tipo del documento: Article