Your browser doesn't support javascript.
loading
Development and validation of liquid chromatography-tandem mass spectrometry method for quantification of plasma metanephrines for differential diagnosis of adrenal incidentaloma.
Lee, Sae Mi; Lee, Mi Na; Oh, Hyeon Ju; Cho, Yoon Young; Kim, Jae Hyeon; Woo, Hye In; Park, Hyung Doo; Lee, Soo Youn.
Afiliación
  • Lee SM; Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Lee MN; Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Oh HJ; Green Cross Laboratories, Seoul, Korea.
  • Cho YY; Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Kim JH; Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Woo HI; Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
  • Park HD; Department of Laboratory Medicine, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Changwon, Korea.
  • Lee SY; Department of Laboratory Medicine and Genetics, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
Ann Lab Med ; 35(5): 519-22, 2015 Sep.
Article en En | MEDLINE | ID: mdl-26206689
ABSTRACT
High-resolution imaging techniques have increased the detection rate of adrenal incidentaloma. We developed a method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) for detection of plasma free metanephrine (MN) and normetanephrine (NMN) and evaluated its analytical performance and clinical efficacy in differential diagnosis of adrenal incidentaloma. After solid-phase extraction, chromatographic isolation of the analytes and internal standard was achieved by column elution in the LC-MS/MS system. The analytes were detected in multiple-reaction monitoring mode by using positive electrospray ionization MN, transition m/z 180.1-->165.1; NMN, m/z 166.1-->134.1. This method was validated for linearity, precision, accuracy, lower limits of quantification and detection, extraction recovery, and the matrix effect. Plasma concentrations of MN and NMN of 14 patients with pheochromocytoma were compared with those of 17 healthy volunteers, 10 patients with essential hypertension, and 60 patients with adrenal adenoma. The assay's linear range was 0.04-50.0 and 0.08-100.0 nmol/L for MN and NMN, respectively. Assay imprecision was 1.86-7.50%. The accuracy ranged from -7.50% to 2.00%, and the mean recovery of MN and NMN was within the range 71.5-95.2%. Our LC-MS/MS method is rapid, accurate, and reliable and useful for differential diagnosis of adrenal incidentaloma.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Metanefrina / Cromatografía Líquida de Alta Presión / Neoplasias de las Glándulas Suprarrenales / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies Límite: Humans Idioma: En Año: 2015 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Metanefrina / Cromatografía Líquida de Alta Presión / Neoplasias de las Glándulas Suprarrenales / Espectrometría de Masas en Tándem Tipo de estudio: Diagnostic_studies / Evaluation_studies / Observational_studies Límite: Humans Idioma: En Año: 2015 Tipo del documento: Article