Your browser doesn't support javascript.
loading
High resolution NMR measurements using a 400MHz NMR with an (RE)Ba2Cu3O7-x high-temperature superconducting inner coil: Towards a compact super-high-field NMR.
Piao, R; Iguchi, S; Hamada, M; Matsumoto, S; Suematsu, H; Saito, A T; Li, J; Nakagome, H; Takao, T; Takahashi, M; Maeda, H; Yanagisawa, Y.
Afiliación
  • Piao R; Center for Life Science Technologies, RIKEN, Yokohama 230-0045, Japan; Graduate School of Engineering, Chiba University, Chiba 236-8522, Japan.
  • Iguchi S; Center for Life Science Technologies, RIKEN, Yokohama 230-0045, Japan; Faculty of Science and Technology, Sophia University, Yotsuya 102-8554, Japan.
  • Hamada M; Japan Superconductor Technology, Inc., Kobe, Hyogo 651-2271, Japan.
  • Matsumoto S; Superconducting Wire Unit, National Institute for Materials Science, Tsukuba 305-0003, Japan.
  • Suematsu H; JEOL RESONANCE Inc., Akishima, Tokyo 196-8558, Japan.
  • Saito AT; Graduate School of Engineering, Chiba University, Chiba 236-8522, Japan.
  • Li J; Graduate School of Engineering, Chiba University, Chiba 236-8522, Japan.
  • Nakagome H; Graduate School of Engineering, Chiba University, Chiba 236-8522, Japan.
  • Takao T; Faculty of Science and Technology, Sophia University, Yotsuya 102-8554, Japan.
  • Takahashi M; Center for Life Science Technologies, RIKEN, Yokohama 230-0045, Japan.
  • Maeda H; Center for Life Science Technologies, RIKEN, Yokohama 230-0045, Japan.
  • Yanagisawa Y; Center for Life Science Technologies, RIKEN, Yokohama 230-0045, Japan; Graduate School of Engineering, Chiba University, Chiba 236-8522, Japan. Electronic address: yoshinori.yanagisawa@riken.jp.
J Magn Reson ; 263: 164-171, 2016 Feb.
Article en En | MEDLINE | ID: mdl-26778351
ABSTRACT
Use of high-temperature superconducting (HTS) inner coils in combination with conventional low-temperature superconducting (LTS) outer coils for an NMR magnet, i.e. a LTS/HTS NMR magnet, is a suitable option to realize a high-resolution NMR spectrometer with operating frequency >1GHz. From the standpoint of creating a compact magnet, (RE Rare earth) Ba2Cu3O7-x (REBCO) HTS inner coils which can tolerate a strong hoop stress caused by a Lorentz force are preferred. However, in our previous work on a first-generation 400MHz LTS/REBCO NMR magnet, the NMR resolution and sensitivity were about ten times worse than that of a conventional LTS NMR magnet. The result was caused by a large field inhomogeneity in the REBCO coil itself and the shielding effect of a screening current induced in that coil. In the present paper, we describe the operation of a modified 400MHz LTS/REBCO NMR magnet with an advanced field compensation technology using a combination of novel ferromagnetic shimming and an appropriate procedure for NMR spectrum line shape optimization. We succeeded in obtaining a good NMR line shape and 2D NOESY spectrum for a lysozyme aqueous sample. We believe that this technology is indispensable for the realization of a compact super-high-field high-resolution NMR.
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Idioma: En Año: 2016 Tipo del documento: Article