Your browser doesn't support javascript.
loading
Performance evaluation of the point-of-care SAMBA I and II HIV-1 Qual whole blood tests.
Ritchie, Allyson V; Goel, Neha; Sembongi, Hiroshi; Lehga, Jesse; Farleigh, Laura E; Edemaga, Daniel; Wisniewski, Craig A; Lee, Helen H.
Afiliación
  • Ritchie AV; Diagnostics Development Unit, Department of Haematology, University of Cambridge, Science Village, Chesterford Research Park, Great Chesterford, CB10 1XL, UK.
  • Goel N; Diagnostics Development Unit, Department of Haematology, University of Cambridge, Science Village, Chesterford Research Park, Great Chesterford, CB10 1XL, UK.
  • Sembongi H; Diagnostics for the Real World EU Ltd., Science Village, Chesterford Research Park, Great Chesterford, CB10 1XL, UK.
  • Lehga J; Diagnostics for the Real World Ltd., 840 Del Rey Avenue, Sunnyvale, CA 94085, USA.
  • Farleigh LE; Diagnostics for the Real World EU Ltd., Science Village, Chesterford Research Park, Great Chesterford, CB10 1XL, UK.
  • Edemaga D; Diagnostics for the Real World Ltd., 840 Del Rey Avenue, Sunnyvale, CA 94085, USA.
  • Wisniewski CA; Diagnostics Development Unit, Department of Haematology, University of Cambridge, Science Village, Chesterford Research Park, Great Chesterford, CB10 1XL, UK; Diagnostics for the Real World Ltd., 840 Del Rey Avenue, Sunnyvale, CA 94085, USA.
  • Lee HH; Diagnostics Development Unit, Department of Haematology, University of Cambridge, Science Village, Chesterford Research Park, Great Chesterford, CB10 1XL, UK; Diagnostics for the Real World Ltd., 840 Del Rey Avenue, Sunnyvale, CA 94085, USA. Electronic address: hl207@cam.ac.uk.
J Virol Methods ; 237: 143-149, 2016 11.
Article en En | MEDLINE | ID: mdl-27568275
ABSTRACT
The SAMBA HIV-1 Qual Whole Blood Test is a nucleic acid-based amplification assay for the qualitative detection of HIV-1 in whole blood of adults or infants. The test can be run on either the semi-automated SAMBA I system for clinical use or the fully automated, including readout, SAMBA II system for point-of-care use in resource-limited settings. We have assessed the performance characteristics of the SAMBA HIV-1 Qual Whole Blood Test on SAMBA I and SAMBA II. The limit of detection obtained for the two tests were 518IU/ml and 399copies/ml on SAMBA I and 457IU/ml and 433copies/ml on SAMBA II. Test specificity on both systems was 100% with a panel of 503 HIV-1 negative samples. Evaluation of test reproducibility showed 100% concordance with expected gold standard results as well as 100% agreement between operators, days, and runs as well as within runs on both SAMBA I and SAMBA II. Our results thus show that the SAMBA HIV-1 Qual Whole Blood Test performs equivalently on SAMBA I and SAMBA II, and also suggest that the test is suitable for implementation in medium-throughput clinical facilities (SAMBA I) or low-throughput point-of-care (POC) settings (SAMBA II) in resource-poor regions.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Infecciones por VIH / VIH-1 / Sistemas de Atención de Punto / Técnicas de Amplificación de Ácido Nucleico Tipo de estudio: Diagnostic_studies / Evaluation_studies / Qualitative_research / Screening_studies Límite: Adult / Humans / Infant Idioma: En Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Infecciones por VIH / VIH-1 / Sistemas de Atención de Punto / Técnicas de Amplificación de Ácido Nucleico Tipo de estudio: Diagnostic_studies / Evaluation_studies / Qualitative_research / Screening_studies Límite: Adult / Humans / Infant Idioma: En Año: 2016 Tipo del documento: Article