Your browser doesn't support javascript.
loading
Nonlinear identification of the total baroreflex arc: higher-order nonlinearity.
Moslehpour, Mohsen; Kawada, Toru; Sunagawa, Kenji; Sugimachi, Masaru; Mukkamala, Ramakrishna.
Afiliación
  • Moslehpour M; Department of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan.
  • Kawada T; Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, Osaka, Japan; and.
  • Sunagawa K; Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
  • Sugimachi M; Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, Osaka, Japan; and.
  • Mukkamala R; Department of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan; rama@egr.msu.edu.
Am J Physiol Regul Integr Comp Physiol ; 311(6): R994-R1003, 2016 12 01.
Article en En | MEDLINE | ID: mdl-27629885
ABSTRACT
The total baroreflex arc is the open-loop system relating carotid sinus pressure (CSP) to arterial pressure (AP). The nonlinear dynamics of this system were recently characterized. First, Gaussian white noise CSP stimulation was employed in open-loop conditions in normotensive and hypertensive rats with sectioned vagal and aortic depressor nerves. Nonparametric system identification was then applied to measured CSP and AP to establish a second-order nonlinear Uryson model. The aim in this study was to assess the importance of higher-order nonlinear dynamics via development and evaluation of a third-order nonlinear model of the total arc using the same experimental data. Third-order Volterra and Uryson models were developed by employing nonparametric and parametric identification methods. The R2 values between the AP predicted by the best third-order Volterra model and measured AP in response to Gaussian white noise CSP not utilized in developing the model were 0.69 ± 0.03 and 0.70 ± 0.03 for normotensive and hypertensive rats, respectively. The analogous R2 values for the best third-order Uryson model were 0.71 ± 0.03 and 0.73 ± 0.03. These R2 values were not statistically different from the corresponding values for the previously established second-order Uryson model, which were both 0.71 ± 0.03 (P > 0.1). Furthermore, none of the third-order models predicted well-known nonlinear behaviors including thresholding and saturation better than the second-order Uryson model. Additional experiments suggested that the unexplained AP variance was partly due to higher brain center activity. In conclusion, the second-order Uryson model sufficed to represent the sympathetically mediated total arc under the employed experimental conditions.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Presorreceptores / Presión Sanguínea / Seno Carotídeo / Barorreflejo / Hipertensión / Modelos Cardiovasculares Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Animals / Humans Idioma: En Año: 2016 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Presorreceptores / Presión Sanguínea / Seno Carotídeo / Barorreflejo / Hipertensión / Modelos Cardiovasculares Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Límite: Animals / Humans Idioma: En Año: 2016 Tipo del documento: Article