Your browser doesn't support javascript.
loading
[Clinical application of multi-electrode synchronous radiofrequency ablation via switching controller for treating large hepatocellular carcinoma].
Zhang, T Q; Zhang, Y Y; Gu, Y K; Gao, F; Huang, Z M; Huang, J H.
Afiliación
  • Zhang TQ; *Department of Imaging and Interventional Radiology, Sun Yat-sen University Cancer Center, Key Laboratory of Oncology in Southern China, Guangzhou 510060, China.
Zhonghua Yi Xue Za Zhi ; 96(35): 2777-2780, 2016 Sep 20.
Article en Zh | MEDLINE | ID: mdl-27686541
ABSTRACT

Objective:

To explore the preliminary clinical efficacy and safety of multi-electrode synchronous radiofrequency ablation via switching controller for treating large hepatocellular carcinoma.

Methods:

A total of 20 patients with large hepatocellular carcinoma from minimally invasive Interventional department of Sun Yat-sen University Cancer Center were enrolled in this retrospective study from December 2013 to December 2014.The procedures were conducted with multi-electrode synchronous radiofrequency ablation via switching controller under CT guidance.The necrosis rate of tumor was assessed by the following imaging examination.The single factor analysis of variance (ANOVA) was employed to compare the total bilirubin, albumin, renal function, blood coagulation function before and after ablation, to evaluate the safety of treatment.

Result:

Twenty patients with a total of 31 lesions accepted 23 times ablation procedures using multi-electrode synchronous radiofrequency ablation via switching controller.The recent evaluation after treatment was as followed complete necrosis rate 51.6% (16/31), nearly complete necrosis rate 22.6% (7/31), partial necrosis rate 9.7% (3/31), treatment effectiveness rate (necrosis rate > 50%) 83.9%.The necrosis rate which was less than half volume of the tumor was only seen in 5 cases with huge hepatocellular carcinoma (16.1%). No dead cases appeared after ablation procedures.The patients' total bilirubin elevated moderately after ablation procedures and reversed to normal level after liver function protection treatment.There were no statistical differences of renal function and blood coagulation function before and after ablation.After ablation procedures, 5 cases (21.7%, 5/23) appeared fever, 6 cases (26.1%) with vomiting, only 3 cases (13.0%, 3/23) with moderately severe pain in 3 days after ablation and remitted after taking oral analgesics in one week.

Conclusion:

The clinical efficacy of multi-electrode synchronous radiofrequency ablation via switching controller for large hepatocellular carcinoma is satisfactory with guaranteed security, which can be a choice for treating large hepatocellular carcinoma.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Ablación por Catéter / Carcinoma Hepatocelular / Neoplasias Hepáticas Tipo de estudio: Guideline / Observational_studies Límite: Humans Idioma: Zh Año: 2016 Tipo del documento: Article