Right ventricular pacemaker lead position is associated with differences in long-term outcomes and complications.
Witt, Chance M; Lenz, Charles J; Shih, Henry H; Ebrille, Elisa; Rosenbaum, Andrew N; van Zyl, Martin; Aung, Htin; Manocha, Kevin K; Deshmukh, Abhishek J; Hodge, David O; Mulpuru, Siva K; Cha, Yong-Mei; Espinosa, Raul E; Asirvatham, Samuel J; Mcleod, Christopher J.
Afiliación
  • Witt CM; Department of Cardiovascular Diseases.
  • Lenz CJ; Department of Cardiovascular Diseases.
  • Shih HH; Department of Medicine.
  • Ebrille E; Department of Cardiovascular Diseases.
  • Rosenbaum AN; Department of Cardiovascular Diseases.
  • van Zyl M; Department of Medicine.
  • Aung H; Department of Cardiovascular Diseases.
  • Manocha KK; Department of Medicine.
  • Deshmukh AJ; Department of Cardiovascular Diseases.
  • Hodge DO; Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota, USA.
  • Mulpuru SK; Department of Cardiovascular Diseases.
  • Cha YM; Department of Cardiovascular Diseases.
  • Espinosa RE; Department of Cardiovascular Diseases.
  • Asirvatham SJ; Department of Cardiovascular Diseases.
  • Mcleod CJ; Department of Cardiovascular Diseases.
J Cardiovasc Electrophysiol ; 28(8): 924-930, 2017 Aug.
Article en En | MEDLINE | ID: mdl-28543771
ABSTRACT

INTRODUCTION:

Cardiac pacing from the right ventricular apex is associated with detrimental long-term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long-term outcomes and lead-related complications associated with differing ventricular lead tip position. METHODS AND

RESULTS:

All adult patients who underwent dual-chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long-term outcomes and lead-related complication rates were recorded. These were compared at 5 years between (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005).

CONCLUSIONS:

Septal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Marcapaso Artificial / Fibrilación Atrial / Estimulación Cardíaca Artificial / Electrodos Implantados / Tabiques Cardíacos Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: En Año: 2017 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Marcapaso Artificial / Fibrilación Atrial / Estimulación Cardíaca Artificial / Electrodos Implantados / Tabiques Cardíacos Tipo de estudio: Etiology_studies / Observational_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: En Año: 2017 Tipo del documento: Article