Your browser doesn't support javascript.
loading
Characteristics of regional bone quality in cervical vertebrae considering BMD: Determining a safe trajectory for cervical pedicle screw fixation.
Kim, Moon-Kyu; Cho, Ho-Jung; Kwak, Dai-Soon; You, Seung-Hoon.
Afiliación
  • Kim MK; Department of Neurosurgery, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea.
  • Cho HJ; Catholic Institute for Applied Anatomy/Department of Anatomy, College of Medicine, The Catholic University of Korea, 222 Banpodaero, Seocho-goo, Seoul 06591, Korea.
  • Kwak DS; Catholic Institute for Applied Anatomy/Department of Anatomy, College of Medicine, The Catholic University of Korea, 222 Banpodaero, Seocho-goo, Seoul 06591, Korea.
  • You SH; Department of Neurosurgery, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea.
J Orthop Res ; 36(1): 217-223, 2018 01.
Article en En | MEDLINE | ID: mdl-28621468
ABSTRACT
This study aimed to report the mechanical strength and characteristics of the lateral mass and pedicle considering BMD for the safe insertion of pedicle screws in the subaxial cervical level. We evaluated BMD and Hounsfield unit (HU) values of cortical bones at the lateral mass and pedicle of C3-7 from CT images in 99 patients. Patients were divided into three groups (Group A, T-score ≥ -1; Group B, -2.5 < T-score < -1.0; Group C, T-score ≤ -2.5). The HU numbers of cortical bone in the vertebral canal (medial wall of the lateral mass; cHU), posterior wall of the transverse foramen (fHU), and medial wall, lateral wall, and trabecular area of the pedicle (mHU, lHU, and pHU, respectively) were measured on the CT images in the middle of the pedicle. A mechanical study was also performed to measure cortical bone strength using 10 fresh cadavers. The cHU and mHU values in Group C were higher than lHU and fHU in Groups A and B, and there was a wide gap between the pHU value and other areas. The penetrating force also had a close correlation with HU number. The mean penetrating force of the medial wall of the lateral mass and the posterior wall of the transverse foramen were 210.08 ± 110.46 and 50.51 ± 46.09 N, respectively. The cortical bones in the vertebral canal and medial wall of the pedicle were stronger than the lateral wall and the trabecular area. The cHU and mHU in the osteoporotic group were higher than fHU and pHU in the normal group. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36217-223, 2018.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Densidad Ósea / Vértebras Cervicales / Tornillos Pediculares Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Año: 2018 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Densidad Ósea / Vértebras Cervicales / Tornillos Pediculares Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Año: 2018 Tipo del documento: Article