Your browser doesn't support javascript.
loading
False ischaemic penumbras in CT perfusion in patients with carotid artery stenosis and changes following angioplasty and stenting. / Falsas penumbras isquémicas en la TC de perfusión en pacientes con estenosis carotídea y cambios después de la angioplastia y stenting.
Mosqueira, A J; Pumar, J M; Arias, S; Rodríguez-Yáñez, M; Blanco Ulla, M; Vázquez Herrero, F; Castillo, J.
Afiliación
  • Mosqueira AJ; Servicio de Neurorradiología, Hospital Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, España. Electronic address: drmosqueiramartinez@gmail.com.
  • Pumar JM; Servicio de Neurorradiología, Hospital Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, España.
  • Arias S; Servicio de Neurología, Hospital Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, España.
  • Rodríguez-Yáñez M; Servicio de Neurología, Hospital Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, España.
  • Blanco Ulla M; Servicio de Neurorradiología, Hospital Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, España.
  • Vázquez Herrero F; Servicio de Neurorradiología, Hospital Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, España.
  • Castillo J; Servicio de Neurología, Hospital Universitario Santiago de Compostela, Santiago de Compostela, A Coruña, España.
Neurologia (Engl Ed) ; 35(1): 24-31, 2020.
Article en En, Es | MEDLINE | ID: mdl-28865944
ABSTRACT

INTRODUCTION:

Carotid artery stenosis influences CT perfusion (CTP) studies, sometimes manifesting as a false ischaemic penumbra (FIP). This study aims to estimate the incidence of FIP in patients with carotid artery stenosis, establish their relationship with the degree of stenosis, and measure quantitative and qualitative changes in CTP after carotid angioplasty and stenting (CAS).

METHODS:

Between October 2013 and June 2015, we prospectively selected 26 patients with carotid stenosis who underwent CAS, with CTP being performed 2-10 days before and after CAS.

RESULTS:

Sixteen patients had unilateral stenosis (11 in the subgroup displaying < 90% stenosis and 5 in the subgroup with ≥ 90% stenosis) and 10 patients had bilateral stenosis. The incidence of FIP in patients with carotid artery stenosis was 38.5%. Risk of FIP increased in direct relation to degree of stenosis, with a relative risk of 11 in the subgroup with ≥ 90% stenosis with respect to the subgroup displaying < 90% stenosis (95% CI, 1.7-71.3; P=.0005). There were statistically significant changes in the parameters CBF, TTP, MTT, and Tmax CTP, which reverted after angioplasty. No significant changes were found in CBV.

CONCLUSIONS:

Carotid artery stenosis involves changes in CTP parameters. Patients with ≥ 90% stenosis carry a high risk of FIP; CTP studies may therefore be misinterpreted in these cases. Changes in CTP parameters are reverted after CAS.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Stents / Circulación Cerebrovascular / Estenosis Carotídea / Angioplastia Tipo de estudio: Etiology_studies / Observational_studies / Qualitative_research / Risk_factors_studies Límite: Aged / Female / Humans / Male País/Región como asunto: Europa Idioma: En / Es Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Tomografía Computarizada por Rayos X / Stents / Circulación Cerebrovascular / Estenosis Carotídea / Angioplastia Tipo de estudio: Etiology_studies / Observational_studies / Qualitative_research / Risk_factors_studies Límite: Aged / Female / Humans / Male País/Región como asunto: Europa Idioma: En / Es Año: 2020 Tipo del documento: Article