A nanobiosensing method based on force measurement of antibody-antigen interaction for direct detection of enterovirus 71 by the chemically modified atomic force microscopic probe.
Hong, Chung-Hung; Hsieh, Chung-Fan; Tseng, Chi-Shin; Huang, Wei-Chih; Guo, Cheng-Yan; Lin, Shiming; Lee, Si-Chen.
Afiliación
  • Hong CH; Graduate Institute of Electronics Engineering, National Taiwan University, Taipei, Taiwan. Electronic address: hongchunghung@gmail.com.
  • Hsieh CF; Department of Biochemistry and Molecular Biology, Chang Gung University, Taoyuan, Taiwan.
  • Tseng CS; National Taiwan University College of Medicine/Hospital, National Taiwan University, Taipei, Taiwan.
  • Huang WC; Institute of Medical Device and Imaging, National Taiwan University, Taipei, Taiwan.
  • Guo CY; Institute of Medical Device and Imaging, National Taiwan University, Taipei, Taiwan.
  • Lin S; Institute of Medical Device and Imaging, National Taiwan University, Taipei, Taiwan. Electronic address: til@ntu.edu.tw.
  • Lee SC; Graduate Institute of Electronics Engineering, National Taiwan University, Taipei, Taiwan; Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan. Electronic address: sclee@ntu.edu.tw.
Microb Pathog ; 111: 292-297, 2017 Oct.
Article en En | MEDLINE | ID: mdl-28867629
ABSTRACT
Hand, Foot and mouth disease (HFMD) is a common disease with high infectivity for children, and enterovirus 71 (EV71) is one of the main pathogens to cause the type of illness. Therefore, the aim of this study was to propose a rapid and effective technique for detecting EV71 directly based on the mechanism of biological intermolecular force by using atomic force microscopy (AFM). At first, we coated EV71 particles on the mica surface and made the EV71 antibodies (anti-EV71) fixed on the AFM tip by means of several chemical procedures. Then, AFM chemically modified tip was applied to measure the unbinding forces between EV71 and anti-EV71 by contact mode. Finally, by using AFM imaging calculating software, the EV71 particle size (mean±SD) was 31.36±3.87 nm (n = 200) and this result was concordance with previous literature. Besides, the force (mean±SD) between EV71 antigen and antibody complex was 336.9±64.7 pN. The force (mean±SD) between anti-EV71 and non-specific specimens was 47.1±15.1 pN and was significantly smaller (P < 0.05). Apparently, the results show that we can precisely identify EV71 infection among the samples by measuring the force magnitude and observing the occurrence of EV71/anti-EV71 unbinding events. Therefore, the combination of AFM system and the chemically modified tip has the potential to be a rapid and effective method for detecting EV71 directly.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Microscopía de Fuerza Atómica / Enterovirus Humano A / Infecciones por Enterovirus / Anticuerpos Antivirales / Antígenos Virales Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Año: 2017 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Técnicas Biosensibles / Microscopía de Fuerza Atómica / Enterovirus Humano A / Infecciones por Enterovirus / Anticuerpos Antivirales / Antígenos Virales Tipo de estudio: Diagnostic_studies / Evaluation_studies Límite: Humans Idioma: En Año: 2017 Tipo del documento: Article