Optimisation of cardiac resynchronisation therapy device selection guided by cardiac magnetic resonance imaging: Cost-effectiveness analysis.
Crespo, Carlos; Linhart, Markus; Acosta, Juan; Soto-Iglesias, David; Martínez, Mikel; Jáuregui, Beatriz; Mira, Áurea; Restovic, Gabriela; Sagarra, Joan; Auricchio, Angelo; Fahn, Bernhard; Boltyenkov, Artem; Lasalvia, Luis; Sampietro-Colom, Laura; Berruezo, Antonio.
Afiliación
  • Crespo C; GM Statistics Department, Universitat de Barcelona, Spain.
  • Linhart M; Axentiva Solutions, Tacoronte, Spain.
  • Acosta J; Institut Clínic de Malalties Cardiovasculars, Hospital Clinic, Universitat de Barcelona, Spain.
  • Soto-Iglesias D; Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Spain.
  • Martínez M; Institut Clínic de Malalties Cardiovasculars, Hospital Clinic, Universitat de Barcelona, Spain.
  • Jáuregui B; Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Spain.
  • Mira Á; Institut Clínic de Malalties Cardiovasculars, Hospital Clinic, Universitat de Barcelona, Spain.
  • Restovic G; Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Spain.
  • Sagarra J; Institut Clínic de Malalties Cardiovasculars, Hospital Clinic, Universitat de Barcelona, Spain.
  • Auricchio A; Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Spain.
  • Fahn B; Cardiology Department, Heart Institute, Teknon Medical Center, Spain.
  • Boltyenkov A; Center for Biomedical Diagnosis (CDB), Hospital Clinic, Spain.
  • Lasalvia L; Department of Biomedicine, University of Barcelona, Spain.
  • Sampietro-Colom L; Health Technology Assessment Unit, Hospital Clinic Barcelona, Spain.
  • Berruezo A; Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS), Spain.
Eur J Prev Cardiol ; 27(6): 622-632, 2020 04.
Article en En | MEDLINE | ID: mdl-31487998
ABSTRACT

BACKGROUND:

A recent study showed that the presence and characteristics of myocardial scar could independently predict appropriate implantable cardioverter-defibrillator therapies and the risk of sudden cardiac death in patients receiving a de novo cardiac resynchronisation device.

DESIGN:

The aim was to evaluate the cost-effectiveness of cardiac magnetic resonance imaging-based algorithms versus clinical practice in the decision-making process for the implantation of a cardiac resynchronisation device pacemaker versus cardiac resynchronisation device implantable cardioverter-defibrillator device in heart failure patients with indication for cardiac resynchronisation therapy.

METHODS:

An incidental Markov model was developed to simulate the lifetime progression of a heart failure patient cohort. Key health variables included in the model were New York Heart Association functional class, hospitalisations, sudden cardiac death and total mortality. The analysis was done from the healthcare system perspective. Costs (€2017), survival and quality-adjusted life years were assessed.

RESULTS:

At 5-year follow-up, algorithm I reduced mortality by 39% in patients with a cardiac resynchronisation device pacemaker who were underprotected due to misclassification by clinical protocol. This approach had the highest quality-adjusted life years (algorithm I 3.257 quality-adjusted life years; algorithm II 3.196 quality-adjusted life years; clinical protocol 3.167 quality-adjusted life years) and the lowest lifetime costs per patient (€20,960, €22,319 and €28,447, respectively). Algorithm I would improve results for three subgroups non-ischaemic, New York Heart Association class III-IV and ≥65 years old. Furthermore, implementing this approach could generate an estimated €702 million in health system savings annually in European Society of Cardiology countries.

CONCLUSION:

The application of cardiac magnetic resonance imaging-based algorithms could improve survival and quality-adjusted life years at a lower cost than current clinical practice (dominant strategy) used for assigning cardiac resynchronisation device pacemakers and cardiac resynchronisation device implantable cardioverter-defibrillators to heart failure patients.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Costos de la Atención en Salud / Selección de Paciente / Terapia de Resincronización Cardíaca / Dispositivos de Terapia de Resincronización Cardíaca / Toma de Decisiones Clínicas / Insuficiencia Cardíaca Tipo de estudio: Guideline / Health_economic_evaluation / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Costos de la Atención en Salud / Selección de Paciente / Terapia de Resincronización Cardíaca / Dispositivos de Terapia de Resincronización Cardíaca / Toma de Decisiones Clínicas / Insuficiencia Cardíaca Tipo de estudio: Guideline / Health_economic_evaluation / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2020 Tipo del documento: Article