Your browser doesn't support javascript.
loading
Simulated coronary arterial hemodynamics of myocardial bridging.
Ding, Hao; Zhang, Ying; Liu, Yujia; Liu, Zhilin; Shi, Chunxun; Nie, Zhichao; Chen, Zhehua; Zeng, Yanjun.
Afiliación
  • Ding H; Shanghai University of Medicine & Health Sciences, Shanghai 201318, P. R. China.
  • Zhang Y; School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
  • Liu Y; School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
  • Liu Z; Shanghai General Hospital, Shanghai 200080, P. R. China.
  • Shi C; School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
  • Nie Z; School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
  • Chen Z; Shanghai University of Medicine & Health Sciences, Shanghai 201318, P. R. China.
  • Zeng Y; Biomechanics & Medical Information Institute, Beijing University of Technology, No. 100 PingLeYuan, Beijing, 100022, P. R. China.
Rev Cardiovasc Med ; 20(4): 273-280, 2019 Dec 30.
Article en En | MEDLINE | ID: mdl-31912719
ABSTRACT
The objective of this study was to explore the effects of myocardial bridge compression on blood flow, normal stress, circumferential stress and shear stress in mural coronary artery. An original mural coronary artery simulative device has been greatly improved and its measured hemodynamic parameters have been expanded from a single stress (normal stress) to multiple stresses to more fully and accurately simulate the true hemodynamic environment under normal stress, circumferential stress and shear stress. This device was used to more fully explore the relationship between hemodynamics and mural coronary atherosclerosis under the combined effects of multiple stresses. Results obtained from the mural coronary artery simulator showed stress abnormality to be mainly located in the proximal mural coronary artery where myocardial bridge compression was intensified and average and fluctuation values (maximum minus minimum) of proximal stress were significantly increased by 27.8% and 139%, respectively. It is concluded that myocardial bridge compression causes abnormalities in the proximal hemodynamics of the mural coronary artery. This is of great significance for understanding the hemodynamic mechanism of coronary atherosclerosis and has potential clinical value for the pathological effect and treatment of myocardial bridge.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Simulación por Computador / Circulación Coronaria / Vasos Coronarios / Puente Miocárdico / Hemodinámica / Modelos Anatómicos / Modelos Cardiovasculares Límite: Humans Idioma: En Año: 2019 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Simulación por Computador / Circulación Coronaria / Vasos Coronarios / Puente Miocárdico / Hemodinámica / Modelos Anatómicos / Modelos Cardiovasculares Límite: Humans Idioma: En Año: 2019 Tipo del documento: Article