Your browser doesn't support javascript.
loading
Pentabromobenzyl-RP versus triazole-HILIC columns for separation of the polar basic analytes famotidine and famotidone: LC method development combined with in silico tools to follow the potential consequences of famotidine gastric instability.
El-Shaheny, Rania; Radwan, Mohamed O; Belal, Fathalla; Yamada, Koji.
Afiliación
  • El-Shaheny R; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt; Department of Hygienic Chemistry, Graduate School of Biomedical Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan. Electronic address: rania_yomna@mans.edu.e
  • Radwan MO; Medicinal and Biological Chemistry Science Farm Joint Research Laboratory, Faculty of Life Sciences, Kumamoto University, 5e1 Oehonmachi, Chuo-ku, Kumamoto, 862-0973, Japan; Department of Drug Discovery, Science Farm Ltd., 1-7-30 Kuhonji, Chuo-ku, Kumamoto, 862-0976, Japan; Chemistry of Natural Comp
  • Belal F; Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura, 35516, Egypt.
  • Yamada K; Medicinal Plant Laboratory, Graduate School of Biomedical Sciences, Nagasaki University, 1-14 Bunkyo-machi, Nagasaki, 852-8521, Japan.
J Pharm Biomed Anal ; 186: 113305, 2020 Jul 15.
Article en En | MEDLINE | ID: mdl-32353682
ABSTRACT
The competence of hydrophilic interaction (HILIC) and reversed phase liquid chromatography (RPLC) modes, employing two new stationary phases triazole- and pentabromobenzyl-bonded silica (PBr), respectively, was inspected for separation of two polar basic analytes famotidine (FAM) and its acidic degradant famotidone (FON). Comparison of the chromatographic efficiency, greenness, and economy aspects showed that the RPLC is superior to the HILIC. Hence, the RPLC method was adopted and validated adhering to the FDA guidelines showing excellent linearity for FAM (1.0-20.0 µg/mL) with a detection limit of 0.14 µg/mL. The method was applied to study the behavior of FAM in simulated gastric juice (SGJ), where it exhibited rapid degradation yielding FON. This degradation pathway is a probable major reason for the poor bioavailability of FAM. The kinetic study of the gastric degradation of FAM in SGJ demonstrated pseudo-first order reaction with a rate constant of 8.1 × 10-3 min-1. Moreover, FAM degradation has been proven to be pH-dependent and catalyzed by the gastric juice components. Hence, in situ buffered dosage form is recommended to overcome or decrease this problem. Molecular docking study shows that FON is missing a crucial stabilizing interaction with the key amino acid Asp98 causing a reduced activity at hH2R receptor relative to FAM. Moreover, ADMET properties prediction revealed some differences in the toxicity, pharmacokinetics, metabolism, and solubility profiles of FAM and FON.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Famotidina / Cromatografía de Fase Inversa / Jugo Gástrico Límite: Humans Idioma: En Año: 2020 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Famotidina / Cromatografía de Fase Inversa / Jugo Gástrico Límite: Humans Idioma: En Año: 2020 Tipo del documento: Article