Effects of Topical Ozone Application on Outcomes after Accelerated Corneal Collagen Cross-linking: An Experimental Study.
Dogan, Aysun Sanal; Gurda, Canan; Caliskan, Sinan; Onder, Evrim; Kaymaz, Figen; Bilgic, Elif.
Afiliación
  • Dogan AS; Department of Ophthalmology, Saglik Bilimleri University, Diskapi Yildirim Beyazit Training and Research Hospital, Ankara, Turkey.
  • Gurda C; Department of Ophthalmology, Saglik Bilimleri University, Diskapi Yildirim Beyazit Training and Research Hospital, Ankara, Turkey.
  • Caliskan S; Department of Ophthalmology, Saglik Bilimleri University, Diskapi Yildirim Beyazit Training and Research Hospital, Ankara, Turkey.
  • Onder E; Department of Pathology, Saglik Bilimleri University, Diskapi Yildirim Beyazit Training and Research Hospital, Ankara, Turkey.
  • Kaymaz F; Department of Histology and Embryology, Hacettepe University, School of Medicine, Ankara, Turkey.
  • Bilgic E; Department of Histology and Embryology, Hacettepe University, School of Medicine, Ankara, Turkey.
J Ophthalmic Vis Res ; 15(3): 289-298, 2020.
Article en En | MEDLINE | ID: mdl-32864059
ABSTRACT

PURPOSE:

Ozone is a trioxygen molecule that spontaneously degrades into oxygen and oxygen free radicals. This study was designed to assess the effects of topical ozone application on outcomes after corneal collagen cross-linking (CXL).

METHODS:

Enucleated fresh cadaver yearling sheep eyes (n = 28) were divided into five groups control (C, n = 6), sham (S, n = 6), ozone only (Z, n = 6), CXL only (X, n = 5), and Ozone + CXL (ZX, n = 5). In all groups, except C, the epithelial layer was removed. In group Z, 20 µg/mL liquid ozone was topically applied. In group X, CXL was performed in the accelerated pulse mode. In group ZX, both CXL and ozone were applied. Post-interventional oxygen levels were determined and corneal confocal microscopy and optical coherence tomography were performed. Corneas were evaluated using light and electron microscopy.

RESULTS:

Pre-interventional central corneal thickness (CCT) was highest in the control group and considerably similar in the remaining groups (P = 0.006). Pre- and post-interventional CCT were significantly different in the ozonated groups (Z and ZX) (P = 0.028; P = 0.043). Demarcation line depths were similar in groups Z, X, and ZX (P = 0.343). Increased stromal tissue reflectivity was observed in groups Z, X, and ZX. Oxygen levels were higher in the ozonated groups (Z and ZX) (P = 0.006), and caspase activity was higher in the CXL groups (X and ZX) (P = 0.028) as compared to the other groups. Group ZX showed tighter, more regular, and parallel fibrils.

CONCLUSION:

Ozone increases corneal stromal oxygenation which can probably augment the effect of CXL. Future studies should investigate the safety and feasibility of ozone application during CXL.