Your browser doesn't support javascript.
loading
pH-modulated aggregation-induced emission of Au/Cu nanoclusters and its application to the determination of urea and dissolved ammonia.
Qu, Fei; Chen, Yanan; Jiang, Dafeng; Zhao, Xian-En.
Afiliación
  • Qu F; The Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, 273165, Shandong, China. qufei3323@163.com.
  • Chen Y; The Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University, Qufu, 273165, Shandong, China. qufei3323@163.com.
  • Jiang D; The Key Laboratory of Life-Organic Analysis, Qufu Normal University, Qufu, 273165, Shandong, China.
  • Zhao XE; The Key Laboratory of Pharmaceutical Intermediates and Analysis of Natural Medicine, Qufu Normal University, Qufu, 273165, Shandong, China.
Mikrochim Acta ; 188(4): 113, 2021 03 06.
Article en En | MEDLINE | ID: mdl-33677619
ABSTRACT
A fluorescence platform is designed based on aggregation-induced emission of Au/Cu nanoclusters (Au/Cu NCs) driven by pH value. When pH increases from 6.0 to 7.0, Au/Cu NCs change from aggregation to dispersion, accompanied by the oxidation of Cu cores. Under the catalysis of urease, urea is hydrolysed to release ammonia, which further undergoes a hydrolysis reaction to produce OH-, causing the pH to increase. The fluorescence of Au/Cu NCs quenches linearly at 590 nm with the excitation wavelength at 320 nm when the concentration of urea varies from 5.0 to 100 µM. The limit of detection (LOD) and limit of quantification (LOQ) of urea are 2.23 and 7.45 µM, respectively. Combined with headspace single-drop microextraction technology, Au/Cu NCs are employed to monitor dissolved ammonia with low-cost and simple operation. The linear range of dissolved ammonia is from 20 to 300 µM. The LOD and LOQ of dissolved ammonia are 7.04 and 23.4 µM, respectively. The relative standard deviation (RSD) values of the intra-day and inter-day precision of urea are 2.4-3.0% and 3.0-3.7%, respectively, and those of dissolved ammonia are in the range 3.4-5.1% (intra-day precision) and 4.2-5.8% (inter-day precision). No interferences have been indentified in the determination of urea and dissolved ammonia. Finally, the proposed method has been applied to determine urea in human urine samples and dissolved ammonia in water samples with satisfactory results.Graphical abstract The pH increase produces the dispersion and decomposition of Au/Cu NCs, leading to the fluorescence quenching. Both urea and dissolved ammonia are detected successfully because they cause the pH change to alkaline.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Urea / Nanopartículas del Metal / Colorantes Fluorescentes / Amoníaco Límite: Humans Idioma: En Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Urea / Nanopartículas del Metal / Colorantes Fluorescentes / Amoníaco Límite: Humans Idioma: En Año: 2021 Tipo del documento: Article