Your browser doesn't support javascript.
loading
[Design of Magnamosis System for Endoscopic Tissue Clamping].
Zhang, Miaomiao; Ji, Lin; Lan, Ting; Liu, Peinan; Zhang, Hanzhi; Mou, Xingyi; Shi, Aihua; Ma, Feng; Lyu, Yi; Yan, Xiaopeng.
Afiliación
  • Zhang M; Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061.
  • Ji L; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061.
  • Lan T; Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061.
  • Liu P; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061.
  • Zhang H; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061.
  • Mou X; Qide College, Xi'an Jiaotong University, Xi'an, 710061.
  • Shi A; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061.
  • Ma F; Qide College, Xi'an Jiaotong University, Xi'an, 710061.
  • Lyu Y; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710061.
  • Yan X; Qide College, Xi'an Jiaotong University, Xi'an, 710061.
Zhongguo Yi Liao Qi Xie Za Zhi ; 45(6): 612-615, 2021 Nov 30.
Article en Zh | MEDLINE | ID: mdl-34862772
ABSTRACT
Based on the principle of magnetic anastomosis technique, the design of magnetic anastomosis system for endoscopic tissue clamping is proposed. The system includes a semi-ring magnet, a special structure transparent cap and a detachable push rod. With the help of the existing digestive endoscopy and endoscopic tissue gripper, the endoscopic close clamping and anastomosis of the bleeding or perforated tissue can be completed. After the anastomosis, the magnet falls off and is discharged through the digestive tract. Animal experiments showed that the system was easy to use, the fistula was clamped firmly, the magnet was discharged for 7~21 days, and there was no magnet retention and digestive tract obstruction. Further safety verification, optimization of endoscopic operation, the system can be used in clinical trial.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Imanes / Magnetismo Límite: Animals Idioma: Zh Año: 2021 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Imanes / Magnetismo Límite: Animals Idioma: Zh Año: 2021 Tipo del documento: Article