Your browser doesn't support javascript.
loading
ptairMS: real-time processing and analysis of PTR-TOF-MS data for biomarker discovery in exhaled breath.
Roquencourt, Camille; Grassin-Delyle, Stanislas; Thévenot, Etienne A.
Afiliación
  • Roquencourt C; Département Métrologie Instrumentation & Information (DM2I), CEA, LIST, Laboratoire Sciences des Données et de la Décision, F-91191 Gif-Sur-Yvette, France.
  • Grassin-Delyle S; Département des maladies des voies respiratoires, Hôpital Foch, Exhalomics, Suresnes 92150, France.
  • Thévenot EA; Département de Biotechnologie de la Santé, Université Paris-Saclay, UVSQ, INSERM, Infection et inflammation, Montigny le Bretonneux 78180, France.
Bioinformatics ; 38(7): 1930-1937, 2022 03 28.
Article en En | MEDLINE | ID: mdl-35043937
ABSTRACT
MOTIVATION Analysis of volatile organic compounds (VOCs) in exhaled breath by proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) is of increasing interest for real-time, non-invasive diagnosis, phenotyping and therapeutic drug monitoring in the clinics. However, there is currently a lack of methods and software tools for the processing of PTR-TOF-MS data from cohorts and suited for biomarker discovery studies.

RESULTS:

We developed a comprehensive suite of algorithms that process raw data from patient acquisitions and generate the table of feature intensities. Notably, we included an innovative two-dimensional peak deconvolution model based on penalized splines signal regression for accurate estimation of the temporal profile and feature quantification, as well as a method to specifically select the VOCs from exhaled breath. The workflow was implemented as the ptairMS software, which contains a graphical interface to facilitate cohort management and data analysis. The approach was validated on both simulated and experimental datasets, and we showed that the sensitivity and specificity of the VOC detection reached 99% and 98.4%, respectively, and that the error of quantification was below 8.1% for concentrations down to 19 ppb. AVAILABILITY AND IMPLEMENTATION The ptairMS software is publicly available as an R package on Bioconductor (doi 10.18129/B9.bioc.ptairMS), as well as its companion experiment package ptairData (doi 10.18129/B9.bioc.ptairData). SUPPLEMENTARY INFORMATION Supplementary data are available at Bioinformatics online.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Percepción del Tiempo / Compuestos Orgánicos Volátiles Límite: Humans Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Percepción del Tiempo / Compuestos Orgánicos Volátiles Límite: Humans Idioma: En Año: 2022 Tipo del documento: Article