Your browser doesn't support javascript.
loading
Comparison Studies on Several Ligands Used in Determination of Cd(II) in Rice by Flame Atomic Absorption Spectrometry after Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction.
Sun, Qian; Cui, Xinyu; Wang, Yanfeng; Zhang, Pingping; Lu, Wenjuan.
Afiliación
  • Sun Q; Institute of Materia Medica, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
  • Cui X; Institute of Materia Medica, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
  • Wang Y; Institute of Materia Medica, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
  • Zhang P; Institute of Materia Medica, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
  • Lu W; Institute of Materia Medica, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan 250062, China.
Molecules ; 27(3)2022 Jan 18.
Article en En | MEDLINE | ID: mdl-35163864
ABSTRACT
Ligands plays an important role in the extraction procedures for the determination of cadmium in rice samples by using flame atomic absorption spectrometry (FAAS). In the present study, comparative evaluation of 10 commercially available ligands for formation of Cd(II)-ligand complex and determination of cadmium in rice samples by ultrasound-assisted dispersive liquid-liquid microextraction (UADLLME) combined with FAAS was developed. Sodium diethyldithiocarbamate (DDTC) provided a high distribution coefficient as well as a good absorbance signal, therefore DDTC was used as a ligand in UADLLME. A low density and less toxic solvent, 1-heptanol, was used as the extraction solvent and ethanol was used as the disperser solvent. In addition, the experimental conditions of UADLLME were optimized in standard solution first and then applied in rice, such as the type and volume of extractant and dispersant, pH, extraction time, and temperature. Under the optimal experimental conditions, the detection limit (3σ) was 0.69 µg/L for Cd(II). The proposed method was applied for the determination of Cd(II) in three different rice samples (polished rice, brown rice, and glutinous rice), the recovery test was carried out, and the results ranged between 96.7 to 113.6%. The proposed method has the advantages of simplicity, low cost, and accurate and was successfully applied to analyze Cd(II) in rice.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Oryza / Solventes / Espectrofotometría Atómica / Contaminantes Químicos del Agua / Cadmio / Quelantes / Microextracción en Fase Líquida Idioma: En Año: 2022 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Oryza / Solventes / Espectrofotometría Atómica / Contaminantes Químicos del Agua / Cadmio / Quelantes / Microextracción en Fase Líquida Idioma: En Año: 2022 Tipo del documento: Article