Your browser doesn't support javascript.
loading
Graphene-on-gold surface plasmon resonance sensors resilient to high-temperature annealing.
Jungnickel, Robert; Mirabella, Francesca; Stockmann, Jörg Manfred; Radnik, Jörg; Balasubramanian, Kannan.
Afiliación
  • Jungnickel R; Department of Chemistry, School of Analytical Sciences Adlershof (SALSA) & IRIS Adlershof, Humboldt-Universität Zu Berlin, 10117, Berlin, Germany.
  • Mirabella F; Federal Institute for Materials Research and Testing (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany.
  • Stockmann JM; SPECS Surface Nano Analysis GmbH, Voltastr. 5, 13355, Berlin, Germany.
  • Radnik J; Federal Institute for Materials Research and Testing (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany.
  • Balasubramanian K; Federal Institute for Materials Research and Testing (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany.
Anal Bioanal Chem ; 415(3): 371-377, 2023 Jan.
Article en En | MEDLINE | ID: mdl-36447098
ABSTRACT
Gold films coated with a graphene sheet are being widely used as sensors for the detection of label-free binding interactions using surface plasmon resonance (SPR). During the preparation of such sensors, it is often essential to subject the sensor chips to a high-temperature treatment in order to ensure a clean graphene surface. However, sensor chips used currently, which often use chromium as an adhesion promoter, cannot be subjected to temperatures above 250 °C, because under such conditions, chromium is found to reorganize and diffuse to the surface, where it is easily oxidized, impairing the quality of SPR spectra. Here we present an optimized preparation strategy involving a three-cycle tempering coupled with chromium (oxide) etching, which allows the graphene-coated SPR chips to be annealed up to 500 °C with little deterioration of the surface morphology. In addition, the treatment delivers a surface that shows a clear enhancement in spectral response together with a good refractive index sensitivity. We demonstrate the applicability of our sensors by studying the kinetics of avidin-biotin binding at different pH repeatedly on the same chip. The possibility to anneal can be exploited to recover the original surface after sensing trials, which allowed us to reuse the sensor for at least six cycles of biomolecule adsorption.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Resonancia por Plasmón de Superficie / Grafito Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Resonancia por Plasmón de Superficie / Grafito Idioma: En Año: 2023 Tipo del documento: Article