Your browser doesn't support javascript.
loading
The electrochemical quantitation method for sugammadex via a molecularly imprinted polymer-based sensor.
Ozcelikay, Goksu; Cetinkaya, Ahmet; Atici, Esen Bellur; Ozkan, Sibel A.
Afiliación
  • Ozcelikay G; Ankara University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, Turkiye. goksu.ozcelikay91@gmail.com.
  • Cetinkaya A; Ankara University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, Turkiye. goksu.ozcelikay91@gmail.com.
  • Atici EB; Ankara University, Graduate School of Health Sciences, Ankara, Turkiye.
  • Ozkan SA; DEVA Holding A.S., R&D Center, Tekirdag, Turkiye.
Anal Methods ; 15(19): 2309-2317, 2023 05 18.
Article en En | MEDLINE | ID: mdl-37129572
ABSTRACT
Sugammadex (SUG) is a synthetically modified γ-cyclodextrin derivative used in hospitals after surgeries to reverse the neuromuscular blockade induced by rocuronium or vecuronium. In this study, we aimed to develop the first electroanalytical quantification method for sugammadex by using molecular imprinting (MIP) via the electropolymerization (EP) technique. An EP-MIP film was formed by EP on a screen-printed gold electrode (SPAuE) and a new electrochemical sensor, EP-MIP(SUG)/SPAuE, was fabricated using the 4-aminophenol monomer with copper ions to enhance the MIP-binding site. Surface and electrochemical characterization of the EP-MIP(SUG)/SPAuE sensor have been done via scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). After screening and optimization studies were carried out to fabricate a MIP-based electrochemical sensor, the analytical performance of EP-MIP(SUG)/SPAuE and the validation parameters were tested according to the ICH guidelines. The specificity/selectivity of the developed sensor has been shown by using common interferents found in the biological fluids and also molecules having similar structures, such as α-cyclodextrin, ß-cyclodextrin, and γ-cyclodextrin. As a result, a quantitative analysis method has been developed and validated by using the EP-MIP(SUG)/SPAuE sensor in the concentration range of 0.1-1.0 pM with very high sensitivity (limit of detection 27.3 fM). The applicability of the method has been shown for bulk drug substances, pharmaceutical dosage forms, and commercial serum samples with good recovery and RSD% results. The EP-MIP(SUG)/SPAuE is the first electrochemical sensor developed for the determination of sugammadex serving the aims of simplicity, short analysis time, and low cost, and has the potential to be adapted in the future as a portable and/or wearable sensor via miniaturization.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Impresión Molecular / Polímeros Impresos Molecularmente Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Impresión Molecular / Polímeros Impresos Molecularmente Idioma: En Año: 2023 Tipo del documento: Article