Your browser doesn't support javascript.
loading
Computed high-b-value high-resolution DWI improves solid lesion detection in IPMN of the pancreas.
Harder, Felix N; Jung, Eva; Weiss, Kilian; Graf, Markus M; Kamal, Omar; McTavish, Sean; Van, Anh T; Demir, Ihsan E; Friess, Helmut; Phillip, Veit; Schmid, Roland M; Lohöfer, Fabian K; Kaissis, Georgios A; Makowski, Marcus R; Karampinos, Dimitrios C; Braren, Rickmer F.
Afiliación
  • Harder FN; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany. Felix.Harder@tum.de.
  • Jung E; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
  • Weiss K; Philips GmbH Market DACH, Röntgenstrasse 22, 22335, Hamburg, Germany.
  • Graf MM; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
  • Kamal O; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
  • McTavish S; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
  • Van AT; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
  • Demir IE; Department of Surgery, Klinikum Rechts Der Isar, School of Medicine, Technical University of Munich, Munich, Germany.
  • Friess H; Department of Medicine II, University Hospital Rechts Der Isar, Technical University Munich, Munich, Germany.
  • Phillip V; Department of Medicine II, University Hospital Rechts Der Isar, Technical University Munich, Munich, Germany.
  • Schmid RM; Department of Medicine II, University Hospital Rechts Der Isar, Technical University Munich, Munich, Germany.
  • Lohöfer FK; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
  • Kaissis GA; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
  • Makowski MR; Department of Computing, Faculty of Engineering, Imperial College of Science, Technology and Medicine, London, SW7 2AZ, UK.
  • Karampinos DC; Institute for Artificial Intelligence in Medicine, Technical University of Munich, Munich, Germany.
  • Braren RF; Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
Eur Radiol ; 33(10): 6892-6901, 2023 Oct.
Article en En | MEDLINE | ID: mdl-37133518
ABSTRACT

OBJECTIVES:

To examine the effect of high-b-value computed diffusion-weighted imaging (cDWI) on solid lesion detection and classification in pancreatic intraductal papillary mucinous neoplasm (IPMN), using endoscopic ultrasound (EUS) and histopathology as a standard of reference.

METHODS:

Eighty-two patients with known or suspected IPMN were retrospectively enrolled. Computed high-b-value images at b = 1000 s/mm2 were calculated from standard (b = 0, 50, 300, and 600 s/mm2) DWI images for conventional full field-of-view (fFOV, 3 × 3 × 4 mm3 voxel size) DWI. A subset of 39 patients received additional high-resolution reduced-field-of-view (rFOV, 2.5 × 2.5 × 3 mm3 voxel size) DWI. In this cohort, rFOV cDWI was compared against fFOV cDWI additionally. Two experienced radiologists evaluated (Likert scale 1-4) image quality (overall image quality, lesion detection and delineation, fluid suppression within the lesion). In addition, quantitative image parameters (apparent signal-to-noise ratio (aSNR), apparent contrast-to-noise ratio (aCNR), contrast ratio (CR)) were assessed. Diagnostic confidence regarding the presence/absence of diffusion-restricted solid nodules was assessed in an additional reader study.

RESULTS:

High-b-value cDWI at b = 1000 s/mm2 outperformed acquired DWI at b = 600 s/mm2 regarding lesion detection, fluid suppression, aCNR, CR, and lesion classification (p = < .001-.002). Comparing cDWI from fFOV and rFOV revealed higher image quality in high-resolution rFOV-DWI compared to conventional fFOV-DWI (p ≤ .001-.018). High-b-value cDWI images were rated non-inferior to directly acquired high-b-value DWI images (p = .095-.655).

CONCLUSIONS:

High-b-value cDWI may improve the detection and classification of solid lesions in IPMN. Combining high-resolution imaging and high-b-value cDWI may further increase diagnostic precision. CLINICAL RELEVANCE STATEMENT This study shows the potential of computed high-resolution high-sensitivity diffusion-weighted magnetic resonance imaging for solid lesion detection in pancreatic intraductal papillary mucinous neoplasia (IPMN). The technique may enable early cancer detection in patients under surveillance. KEY POINTS • Computed high-b-value diffusion-weighted imaging (cDWI) may improve the detection and classification of intraductal papillary mucinous neoplasms (IPMN) of the pancreas. • cDWI calculated from high-resolution imaging increases diagnostic precision compared to cDWI calculated from conventional-resolution imaging. • cDWI has the potential to strengthen the role of MRI for screening and surveillance of IPMN, particularly in view of the rising incidence of IPMNs combined with now more conservative therapeutic approaches.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neoplasias Pancreáticas / Neoplasias Intraductales Pancreáticas Tipo de estudio: Diagnostic_studies / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Neoplasias Pancreáticas / Neoplasias Intraductales Pancreáticas Tipo de estudio: Diagnostic_studies / Observational_studies / Risk_factors_studies Límite: Humans Idioma: En Año: 2023 Tipo del documento: Article