Verification of the sampling procedure for radioactivity analysis of waste and industrial material.
Rajacic, Milica M; Todorovic, Dragana J; Andric, Velibor D; Nikolic, Jelena K; Jankovic, Marija M; Pantelic, Gordana K; Vukanac, Ivana S.
Afiliación
  • Rajacic MM; Vinca Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovica Alasa 12-14, Belgrade 11001, Serbia.
  • Todorovic DJ; Vinca Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovica Alasa 12-14, Belgrade 11001, Serbia.
  • Andric VD; Vinca Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovica Alasa 12-14, Belgrade 11001, Serbia.
  • Nikolic JK; Vinca Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovica Alasa 12-14, Belgrade 11001, Serbia.
  • Jankovic MM; Vinca Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovica Alasa 12-14, Belgrade 11001, Serbia.
  • Pantelic GK; Vinca Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovica Alasa 12-14, Belgrade 11001, Serbia.
  • Vukanac IS; Vinca Institute of Nuclear Sciences, National Institute of the Republic of Serbia, University of Belgrade, Mike Petrovica Alasa 12-14, Belgrade 11001, Serbia.
Radiat Prot Dosimetry ; 199(8-9): 941-946, 2023 May 24.
Article en En | MEDLINE | ID: mdl-37225179
ABSTRACT
In accordance with ISO/IEC 170252017, the testing laboratory needs to verify its ability to properly perform methods. For radiological testing, the sampling does not affect the results directly, but it has to ensure that sample adequately represents the tested material. To verify the procedure, a sampling of red mud and bauxite ore was conducted. All samples were measured in identical geometry by HPGe spectrometer. The counting rates per unit mass in the recorded spectra were compared. For each measurement series, the mean and standard deviations of respected peaks were calculated, as well as average and standard deviation of all series. The obtained results of each individual series were considered satisfactory, i.e. sampling procedure ensures the representativeness of the bulk material, if it is within ± two standard deviations of the average of the mean values.