Deep learning reconstruction for improving the visualization of acute brain infarct on computed tomography.
Okimoto, Naomasa; Yasaka, Koichiro; Fujita, Nana; Watanabe, Yusuke; Kanzawa, Jun; Abe, Osamu.
Afiliación
  • Okimoto N; Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo, 113-8655, Japan.
  • Yasaka K; Department of Radiology, Tokyo Metropolitan Bokutoh Hospital, 4-23-15 Kotobashi, Sumida-Ku, Tokyo, 130-8575, Japan.
  • Fujita N; Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo, 113-8655, Japan. koyasaka@gmail.com.
  • Watanabe Y; Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo, 113-8655, Japan.
  • Kanzawa J; Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo, 113-8655, Japan.
  • Abe O; Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-Ku, Tokyo, 113-8655, Japan.
Neuroradiology ; 66(1): 63-71, 2024 Jan.
Article en En | MEDLINE | ID: mdl-37991522
ABSTRACT

PURPOSE:

This study aimed to investigate the impact of deep learning reconstruction (DLR) on acute infarct depiction compared with hybrid iterative reconstruction (Hybrid IR).

METHODS:

This retrospective study included 29 (75.8 ± 13.2 years, 20 males) and 26 (64.4 ± 12.4 years, 18 males) patients with and without acute infarction, respectively. Unenhanced head CT images were reconstructed with DLR and Hybrid IR. In qualitative analyses, three readers evaluated the conspicuity of lesions based on five regions and image quality. A radiologist placed regions of interest on the lateral ventricle, putamen, and white matter in quantitative analyses, and the standard deviation of CT attenuation (i.e., quantitative image noise) was recorded.

RESULTS:

Conspicuity of acute infarct in DLR was superior to that in Hybrid IR, and a statistically significant difference was observed for two readers (p ≤ 0.038). Conspicuity of acute infarct with time from onset to CT imaging at < 24 h in DLR was significantly improved compared with Hybrid IR for all readers (p ≤ 0.020). Image noise in DLR was significantly reduced compared with Hybrid IR with both the qualitative and quantitative analyses (p < 0.001 for all).

CONCLUSION:

DLR in head CT helped improve acute infarct depiction, especially those with time from onset to CT imaging at < 24 h.