Your browser doesn't support javascript.
loading
Application of PAT Probes in Aluminum Phosphate Adjuvant Manufacturing.
Kowal, Przemyslaw; Fung, Ginny; Gemmiti, Gabriel; Sampaleanu, Liliana; Cronin, James T; Kirkitadze, Marina.
Afiliación
  • Kowal P; Analytical Sciences, Vaccine CMC Development and Supply, Sanofi, Toronto, ON, M2R 3T4, Canada.
  • Fung G; Analytical Sciences, Vaccine CMC Development and Supply, Sanofi, Toronto, ON, M2R 3T4, Canada.
  • Gemmiti G; Manufacturing Sciences, Analytics and Technology, Sanofi, Toronto, Canada.
  • Sampaleanu L; Manufacturing Sciences, Analytics and Technology, Sanofi, Toronto, Canada.
  • Cronin JT; Mettler Toledo AutoChem Inc., Columbia, MD, USA.
  • Kirkitadze M; Analytical Sciences, Vaccine CMC Development and Supply, Sanofi, Toronto, ON, M2R 3T4, Canada. Marina.Kirkitadze@sanofi.com.
Pharm Res ; 41(2): 375-385, 2024 Feb.
Article en En | MEDLINE | ID: mdl-38114802
ABSTRACT

PURPOSE:

This study is focused on monitoring process parameters and quality attributes of aluminum phosphate (AlPO4) using multiple in-line probes incorporated into an industrial-scale adjuvant suspension manufacturing unit.

METHODS:

The manufacturing of aluminum adjuvant suspension was monitored at manufacturing scale using conductivity, turbidity, infrared, and particle sizing and count probes to follow the continuous evolution of particle formation and size distribution, and the reaction kinetics during the synthesis of AlPO4.

RESULTS:

The data showed that AlPO4 forms large particles at the early stages of mixing, followed by a decrease in size and then stabilization towards the later stages of mixing and pH adjustment. The results provided a complementary view of process events and assisted in optimizing several parameters, e.g., flow rate of reactants AlCl3 and Na3PO4 solutions, mixing rate, pH, and conductivity of AlPO4, as well as adjuvant quality attribute such as particle size, thus streamlining and shortening the process development stage.

CONCLUSION:

The results of this study showed the usefulness of the in-line probes to automate continuous assessment of AlPO4 batch-to-batch consistency during in-house adjuvant production at the industrial scale.