Your browser doesn't support javascript.
loading
Clinical performance after implantation of an EDOF intraocular lens in the dominant eye and a presbyopia-correcting intraocular lens in the nondominant eye.
Soscia, William L; DeRojas, Joaquin O; Mathews, Priya M; Brutsky, Amy; Solomon, Kerry D; Potvin, Richard; Sandoval, Helga P.
Afiliación
  • Soscia WL; From the Center For Sight/US Eye, Sarasota, Florida (Soscia, DeRojas, Mathews, Brutsky); Carolina Eyecare Physicians/US Eye, Mt. Pleasant, South Carolina (Solomon, Sandoval); Science in Vision, Frisco, Texas (Potvin).
J Cataract Refract Surg ; 50(6): 578-584, 2024 Jun 01.
Article en En | MEDLINE | ID: mdl-38305420
ABSTRACT

PURPOSE:

To evaluate subjective and objective outcomes after combined implantation of an extended depth-of-focus (EDOF) intraocular lens (IOL) and a combined technology multifocal lens (CT-IOL).

SETTING:

2 clinical practices (Carolina Eyecare Physicians, Center For Sight) in the United States.

DESIGN:

Prospective, unmasked, multicenter, nonrandomized bilateral eye study.

METHODS:

Patients interested in reducing their dependence on spectacles were implanted with an EDOF IOL in the dominant eye and a CT-IOL in the nondominant eye. Refractive and visual acuity (VA) data at various distances (4 m, 66 cm, 40 cm, and 33 cm) were collected 3 months postsurgery, along with the distance-corrected binocular defocus curve and responses to questionnaires related to spectacle independence, visual disturbances, and overall visual function.

RESULTS:

Data from 37 participants were analyzed. The distance-corrected binocular defocus curve showed a mean VA better than 0.1 logMAR (20/25) at all vergences from +1.00 to -2.50 diopters (D). 36 participants (97%) had an uncorrected binocular VA of 0.3 logMAR or better, at all test distances. 70% of participants (26/37) reported never wearing spectacles at any distance, and 84% (31/37) were "completely" or "mostly" satisfied with their overall vision after surgery. Halos were the disturbance reported most frequently and reported as most bothersome, with difficulty driving at night the most common visual function issue. Difficulty reading was the next most reported issue. Overall eyesight was rated as "excellent" or "good" by 92% (34/37) of participants.

CONCLUSIONS:

This combined EDOF/CT-IOL approach was well-tolerated by participants and provided some potential benefits relative to bilateral implantation of either lens.
Asunto(s)

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Presbiopía / Refracción Ocular / Visión Binocular / Agudeza Visual / Facoemulsificación / Seudofaquia / Implantación de Lentes Intraoculares Tipo de estudio: Clinical_trials Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Presbiopía / Refracción Ocular / Visión Binocular / Agudeza Visual / Facoemulsificación / Seudofaquia / Implantación de Lentes Intraoculares Tipo de estudio: Clinical_trials Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Año: 2024 Tipo del documento: Article