Your browser doesn't support javascript.
loading
Extended balloon stent placement for reducing intrauterine adhesion recurrence: a retrospective cohort study.
Luo, Yiyang; Liu, Yuhuan; Xie, Wei; Guo, Yan; Xiao, Yu.
Afiliación
  • Luo Y; Hysteroscopic Center, Fuxing Hospital, The Eighth Clinical Medical College, Capital Medical University, Beijing, China.
  • Liu Y; Hysteroscopic Center, Fuxing Hospital, The Eighth Clinical Medical College, Capital Medical University, Beijing, China. Electronic address: liuyh3844@126.com.
  • Xie W; Hysteroscopic Center, Fuxing Hospital, The Eighth Clinical Medical College, Capital Medical University, Beijing, China.
  • Guo Y; Hysteroscopic Center, Fuxing Hospital, The Eighth Clinical Medical College, Capital Medical University, Beijing, China.
  • Xiao Y; Hysteroscopic Center, Fuxing Hospital, The Eighth Clinical Medical College, Capital Medical University, Beijing, China.
Reprod Biomed Online ; 49(2): 103947, 2024 Aug.
Article en En | MEDLINE | ID: mdl-38810315
ABSTRACT
RESEARCH QUESTION What are the efficacy, safety and reproductive outcomes of intrauterine balloon stent placement for 4 or 6 weeks after hysteroscopic adhesiolysis?

DESIGN:

This retrospective cohort study was conducted at a university-affiliated hospital, and included 155 women with moderate to severe intrauterine adhesions who underwent hysteroscopic adhesiolysis between March 2016 and December 2019. Participants were divided according to whether the heart-shaped balloon stent was left in place for 4 (group 1) or 6 (group 2) weeks after surgery. Stents removed at the second-look hysteroscopy 4 or 6 weeks after surgery were sent for culturing of common bacteria. The incidence of adhesion reformation, adhesion score reduction, bacterial colonization of the intrauterine balloon stent, live birth rate and time to live birth were analysed.

RESULTS:

Group 2 had a significantly lower adhesion reformation rate (45.7% versus 28.2%, P = 0.024) and a more significant reduction in adhesion score (5.2 ± 2.1 versus 6.3 ± 2.2, P = 0.003) compared with group 1. However, no statistical difference was observed in the percentage of bacterial colonization of the intrauterine balloon stent (55.9% versus 66.7%, P = 0.174), live birth rate (52.4% versus 42.3%, P = 0.331) or time to live birth (hazard ratio 1.09, 95% confidence interval 0.60-1.96, P = 0.778) between the two groups.

CONCLUSIONS:

Extending intrauterine balloon stent use from 4 to 6 weeks further reduces the adhesion reformation rate after hysteroscopic adhesiolysis in patients with moderate to severe intrauterine adhesion. No increase in bacterial colonization of the balloon stent was observed. Extending the duration of intrauterine balloon stent placement did not significantly affect live birth rates.
Asunto(s)
Palabras clave

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Enfermedades Uterinas / Histeroscopía / Stents Límite: Adult / Female / Humans / Pregnancy Idioma: En Año: 2024 Tipo del documento: Article

Texto completo: 1 Banco de datos: MEDLINE Asunto principal: Enfermedades Uterinas / Histeroscopía / Stents Límite: Adult / Female / Humans / Pregnancy Idioma: En Año: 2024 Tipo del documento: Article