Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Ann Chir Plast Esthet ; 69(1): 27-33, 2024 Jan.
Article in French | MEDLINE | ID: mdl-37121845

ABSTRACT

INTRODUCTION: Local anesthetics with adrenaline are widely used in routine practice and have long proven their benefits and safety. The rare complications due to their use mainly concern immuno-allergic and vascular mechanisms. DESCRIPTION: In this article, we present four similar cases of early transfixing skin necrosis occurring after radioguided breast biopsy under local anesthesia using epinephrine local anesthetics in the context of a diagnostic approach to breast cancer. DISCUSSION: Although the literature is comforting about the use of local anesthetics, even on the extremities, severe skin complications continue to be reported sporadically. The analysis and understanding of these phenomena would allow, in the long run, to avoid them and to reduce their importance. CONCLUSION: The occurrence of skin necrosis after breast biopsy under radiographic control is rare and seems to be related to the local anesthetic procedure. Although similar cases have been reported in the literature, it does not seem possible today to conclude on the exact physiopathology of these complications. A better knowledge of the pathophysiology of these complications would help to avoid their occurrence in the future.


Subject(s)
Anesthesia, Local , Anesthetics, Local , Humans , Anesthesia, Local/adverse effects , Anesthesia, Local/methods , Anesthetics, Local/adverse effects , Breast/surgery , Epinephrine/adverse effects , Biopsy , Necrosis
2.
J Surg Oncol ; 123(4): 815-822, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33524172

ABSTRACT

BACKGROUND AND OBJECTIVES: During the worldwide pandemic of coronavirus disease 2019 (COVID-19), oncological procedures considered to be urgent could not be delayed, and a specific procedure was required to continue surgical activity. The objective was to assess the efficacy of our preoperative screening algorithm. METHODS: This observational retrospective study was performed between the 25th of March and the 12th of May 2020 in a comprehensive cancer center in France. Patients undergoing elective oncologic surgery were tested by preoperative nasopharyngeal reverse-transcription polymerase chain reaction (RT-PCR) that could be associated with a chest computerized tomography (CT) scan. RESULTS: Of the 510 screening tests (in 477 patients), only 5% (15/477) were positive for COVID-19 in 24 patients (18 RT-PCR+ and 7 CT scan+/RT-PCR-). Four patients were ultimately false positives based on the CT scan. In total, only 4.2% (20/477) of the patients were COVID-19+. The positivity rate decreased with time after the containment measures were implemented (from 7.4% to 0.8%). In the COVID-19+ group, 20% of the patients had postoperative pulmonary complications, whereas this was the case for 5% of the patients in the COVID-19 group. CONCLUSIONS: Maintaining secure surgical activity is achievable and paramount in oncology care, even during the COVID-19 pandemic, with appropriate screening based on preoperative RT-PCR.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19/diagnosis , Infection Control/organization & administration , Neoplasms/surgery , Postoperative Complications/epidemiology , Reverse Transcriptase Polymerase Chain Reaction , Adult , Aged , Aged, 80 and over , Algorithms , Cancer Care Facilities , Female , France , Humans , Incidence , Male , Middle Aged , Neoplasms/complications , Neoplasms/pathology , Predictive Value of Tests , Preoperative Care , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed , Young Adult
3.
Eur J Nucl Med Mol Imaging ; 47(1): 28-50, 2020 01.
Article in English | MEDLINE | ID: mdl-31637482

ABSTRACT

Positron emission tomography/computed tomography (PET/CT) is a nuclear medicine functional imaging technique with proven clinical value in oncology. PET/CT indications are continually evolving with fresh advances made through research. French practice on the use of PET in oncology was framed in recommendations based on Standards-Options-Recommendations methodology and coordinated by the French federation of Comprehensive Cancer Centres (FNLCC). The recommendations were originally issued in 2002 followed by an update in 2003, but since then, a huge number of scientific papers have been published and new tracers have been licenced for market release. The aim of this work is to bring the 2003 version recommendations up to date. For this purpose, a focus group was set up in collaboration with the French Society for Nuclear Medicine (SFMN) to work on developing good clinical practice recommendations. These good clinical practice recommendations have been awarded joint French National Heath Authority (HAS) and French Cancer Institute (INCa) label status-the stamp of methodological approval. The present document is the outcome of comprehensive literature review and rigorous appraisal by a panel of experts, organ specialists, clinical oncologists, surgeons and imaging specialists. These data were also used for the EANM referral guidelines.


Subject(s)
Neoplasms , Nuclear Medicine , Humans , Medical Oncology , Neoplasms/diagnostic imaging , Positron Emission Tomography Computed Tomography
4.
Eur J Cancer ; 85: 23-30, 2017 11.
Article in English | MEDLINE | ID: mdl-28881248

ABSTRACT

INTRODUCTION: A short-term radiologic follow-up after a benign breast biopsy or fine needle aspiration (FNA) is recommended in many guidelines. However, the current trend is to reduce imaging investigations, radiation dose and costs. The objectives of this study were to evaluate the cancer detection rate at short-term follow-up and to estimate its cost. METHODS: We retrospectively assessed all consecutive patients referred to our 'one-stop' breast unit between 2004 and 2012, with a benign histological or cytological result and at least one short-term follow-up within 3-12 months after the initial diagnosis. We evaluated the number of cancers detected, as well as the mean cost to detect each cancer and per patient. RESULTS: About 1366 patients were eligible for this study. Ten patients were diagnosed with cancers (0.73%) at short-term follow-up; six of 10 were low-grade tumours or ductal carcinoma in situ. The cost for detecting one cancer was 19,043€, with mean cost per patient of 139€. CONCLUSION: The cancer detection rate at short-term follow-up after benign biopsy or FNA was low and was similar to that of most national screening programs. The cost of cancer detection appeared high, considering that most cancers were indolent. This suggests that radiologic follow-up could reasonably be carried out at a later point in time.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/economics , Carcinoma, Intraductal, Noninfiltrating/diagnostic imaging , Carcinoma, Intraductal, Noninfiltrating/economics , Delivery of Health Care, Integrated/economics , Early Detection of Cancer/economics , Health Care Costs , Mammography/economics , Adolescent , Adult , Aged , Aged, 80 and over , Biopsy , Breast Neoplasms/pathology , Carcinoma, Intraductal, Noninfiltrating/pathology , Cost-Benefit Analysis , Early Detection of Cancer/methods , Female , Humans , Magnetic Resonance Imaging/economics , Mammography/methods , Middle Aged , Neoplasm Grading , Predictive Value of Tests , Prognosis , Program Evaluation , Retrospective Studies , Time Factors , Ultrasonography, Mammary/economics , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL