Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Publication year range
1.
Ann Vasc Surg ; 102: 64-73, 2024 May.
Article in English | MEDLINE | ID: mdl-38301848

ABSTRACT

BACKGROUND: Local anesthesia (LA) is sparsely used in endovascular aneurysm repair (EVAR) despite short-term benefit, likely secondary to concerns over patient movement preventing accurate endograft deployment. The objective of this study is to examine the association between anesthesia type and endoleak, sac regression, reintervention, and mortality. METHODS: The Vascular Quality Initiative database was queried for all EVAR cases from 2014 to 2022. Patients were included if they underwent percutaneous elective EVAR with anatomical criteria within instructions for use of commercially approved endografts. Multivariable logistic regression with propensity score weighting was used to determine the association between anesthesia type on the risk of any endoleak noted by intraoperative completion angiogram and sac regression. Multivariable survival analysis with propensity score weighting was used to determine the association between anesthesia type and endoleak at 1 year, long-term reintervention, and mortality. RESULTS: Thirteen thousand nine hundred thirty two EVARs met inclusion criteria: 1,075 (8%) LA and 12,857 (92%) general anesthesia (GA). On completion angiogram, LA was associated with fewer rates of any endoleaks overall (16% vs. 24%, P < 0.001). On multivariable analysis with propensity score weighting, LA was associated with similar adjusted odds of any endoleak on intraoperative completion angiogram (odds ratio [OR] 0.56, 95% confidence interval [CI] 0.47-0.68) as well as combined type 1a and type 1b endoleaks (OR 0.72, 95% CI 0.47-1.09). Follow-up computed tomography imaging at 1 year was available for 4,892 patients, 377 (8%) LA and 4,515 (92%) GA. At 1 year, LA was associated with similar rate of freedom from any endoleaks compared to GA (0.66 [95% CI 0.63-0.69] vs. 0.71 [95% CI 0.70-0.72], P = 0.663) and increased rates of sac regression (50% vs. 45%, P = 0.040). On multivariable analysis with propensity score weighting, LA and GA were associated with similar adjusted odds of sac regression (OR 1.22, 95% CI 0.97-1.55). LA and GA had similar rates of endoleak at 1 year (hazard ratio [HR] 0.14, 95% CI 0.63-1.07); however, LA was associated with decreased hazards of combined type 1a and 1b endoleaks at 1 year (HR 0.87, 95% CI 0.80-0.96). LA and GA had similar adjusted long-term reintervention rate (HR 0.77, 95% CI 0.44-1.38) and long-term mortality (HR 1.100, 95% CI 079-1.25). CONCLUSIONS: LA is not associated with increased adjusted rates of any endoleak on completion angiogram or at 1-year follow-up compared to GA. LA is associated with decreased adjusted rates of type 1a and type 1b endoleak at 1 year, but similar rates of sac regression, long-term reintervention, and mortality. Concerns for accurate graft deployment should not preclude use of LA and LA should be increasingly considered when deciding on anesthetic type for standard elective EVAR.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Anesthesia, Local/adverse effects , Endoleak/diagnostic imaging , Endoleak/etiology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Risk Factors , Treatment Outcome , Aortography/methods , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL