ABSTRACT
Vacuum ultraviolet-ozone (VUV-O3) treatment was found to be superior to ultraviolet-ozone (UV-O3) treatment in terms of ozone utilization and hydroxyl radicals (·OH) generation when used to treat the secondary effluent (SE) from a naproxen pharmaceutical plant. VUV-O3 treatment was beneficial in terms of decolorization (100%), chemical oxygen demand removal (43.29%), and total organic carbon removal (54.81%). The VUV-O3 process was applicable over a wide pH range, and the presence of various anions had no significant influence on the oxidation efficiency. After treatment, the genotoxicity, unsaturation degree, and polarity of the SE decreased. In addition, the oxidation sensitivities of the fluorescent organic compounds were ranked as follows: humic acid-like > tyrosine-like > fulvic acid-like > tryptophan-like Moreover, the VUV-O3 process effectively converted refractory organic matter (molecular weights, MW > 2000 Da) into short-chain molecules with low MWs. The removal efficiency of dissolved organic matter (DOM) was 63.27%, and 77.27% of the DOM was found to be reactive to VUV-O3 oxidation. The unsaturation, polarity, and compositional complexity of the DOM decreased after VUV-O3 treatment. Finally, it was deduced that the direct O3 oxidation,·OH, O2·- and 1O2 played a role in the VUV-O3 oxidation process.