Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
Nitric Oxide ; 104-105: 29-35, 2020 11 01.
Article in English | MEDLINE | ID: mdl-32835810

ABSTRACT

BACKGROUND: There is an increasing interest in safely delivering high dose of inhaled nitric oxide (NO) as an antimicrobial and antiviral therapeutics for spontaneously breathing patients. A novel NO delivery system is described. METHODS: We developed a gas delivery system that utilizes standard respiratory circuit connectors, a reservoir bag, and a scavenging chamber containing calcium hydroxide. The performance of the system was tested using a mechanical lung, assessing the NO concentration delivered at varying inspiratory flows. Safety was assessed in vitro and in vivo by measuring nitrogen dioxide (NO2) levels in the delivered NO gas. Lastly, we measured the inspired and expired NO and NO2 of this system in 5 healthy subjects during a 15-min administration of high dose NO (160 parts-per-million, ppm) using our delivery system. RESULTS: The system demonstrated stable delivery of prescribed NO levels at various inspiratory flow rates (0-50 L/min). The reservoir bag and a high flow of entering air minimized the oscillation of NO concentrations during inspiration on average 4.6 ppm for each 10 L/min increment in lung inspiratory flow. The calcium hydroxide scavenger reduced the inhaled NO2 concentration on average 0.9 ppm (95% CI -1.58, -0.22; p = .01). We performed 49 NO administrations of 160 ppm in 5 subjects. The average concentration of inspired NO was 164.8±10.74 ppm, with inspired NO2 levels of 0.7±0.13 ppm. The subjects did not experience any adverse events; transcutaneous methemoglobin concentrations increased from 1.05±0.58 to 2.26±0.47%. CONCLUSIONS: The system we developed to administer high-dose NO for inhalation is easy to build, reliable, was well tolerated in healthy subjects.


Subject(s)
Drug Delivery Systems/instrumentation , Drug Delivery Systems/methods , Nitric Oxide/administration & dosage , Administration, Inhalation , Adult , Female , Humans , Male , Respiration
2.
Am Heart J ; 177: 66-73, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27297851

ABSTRACT

OBJECTIVE: Patients undergoing cardiac surgery are at risk of perioperative low cardiac output syndrome due to postoperative myocardial dysfunction. Myocardial dysfunction in patients undergoing cardiac surgery is a potential indication for the use of levosimendan, a calcium sensitizer with 3 beneficial cardiovascular effects (inotropic, vasodilatory, and anti-inflammatory), which appears effective in improving clinically relevant outcomes. DESIGN: Double-blind, placebo-controlled, multicenter randomized trial. SETTING: Tertiary care hospitals. INTERVENTIONS: Cardiac surgery patients (n = 1,000) with postoperative myocardial dysfunction (defined as patients with intraaortic balloon pump and/or high-dose standard inotropic support) will be randomized to receive a continuous infusion of either levosimendan (0.05-0.2 µg/[kg min]) or placebo for 24-48 hours. MEASUREMENTS AND MAIN RESULTS: The primary end point will be 30-day mortality. Secondary end points will be mortality at 1 year, time on mechanical ventilation, acute kidney injury, decision to stop the study drug due to adverse events or to start open-label levosimendan, and length of intensive care unit and hospital stay. We will test the hypothesis that levosimendan reduces 30-day mortality in cardiac surgery patients with postoperative myocardial dysfunction. CONCLUSIONS: This trial is planned to determine whether levosimendan could improve survival in patients with postoperative low cardiac output syndrome. The results of this double-blind, placebo-controlled randomized trial may provide important insights into the management of low cardiac output in cardiac surgery.


Subject(s)
Cardiac Output, Low/therapy , Cardiotonic Agents/therapeutic use , Hydrazones/therapeutic use , Intra-Aortic Balloon Pumping , Postoperative Complications/therapy , Pyridazines/therapeutic use , Acute Kidney Injury/epidemiology , Cardiac Output, Low/mortality , Cardiac Surgical Procedures/mortality , Double-Blind Method , Humans , Infusions, Intravenous , Intensive Care Units , Length of Stay/statistics & numerical data , Postoperative Complications/mortality , Respiration, Artificial , Simendan
SELECTION OF CITATIONS