Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Ann Biomed Eng ; 49(10): 2901-2913, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34244908

ABSTRACT

Brain tissue deformation resulting from head impacts is primarily caused by rotation and can lead to traumatic brain injury. To quantify brain injury risk based on measurements of kinematics on the head, finite element (FE) models and various brain injury criteria based on different factors of these kinematics have been developed, but the contribution of different kinematic factors has not been comprehensively analyzed across different types of head impacts in a data-driven manner. To better design brain injury criteria, the predictive power of rotational kinematics factors, which are different in (1) the derivative order (angular velocity, angular acceleration, angular jerk), (2) the direction and (3) the power (e.g., square-rooted, squared, cubic) of the angular velocity, were analyzed based on different datasets including laboratory impacts, American football, mixed martial arts (MMA), NHTSA automobile crashworthiness tests and NASCAR crash events. Ordinary least squares regressions were built from kinematics factors to the 95% maximum principal strain (MPS95), and we compared zero-order correlation coefficients, structure coefficients, commonality analysis, and dominance analysis. The angular acceleration, the magnitude and the first power factors showed the highest predictive power for the majority of impacts including laboratory impacts, American football impacts, with few exceptions (angular velocity for MMA and NASCAR impacts). The predictive power of rotational kinematics about three directions (x: posterior-to-anterior, y: left-to-right, z: superior-to-inferior) of kinematics varied with different sports and types of head impacts.


Subject(s)
Accidents, Traffic , Brain Injuries, Traumatic/physiopathology , Football/injuries , Martial Arts/injuries , Models, Statistical , Acceleration , Automobiles , Biomechanical Phenomena , Data Interpretation, Statistical , Head , Humans , Mouth Protectors , Regression Analysis , Rotation , Wearable Electronic Devices
2.
Epilepsia ; 62(1): 74-84, 2021 01.
Article in English | MEDLINE | ID: mdl-33236777

ABSTRACT

OBJECTIVE: Intracranial electrographic localization of the seizure onset zone (SOZ) can guide surgical approaches for medically refractory epilepsy patients, especially when the presurgical workup is discordant or functional cortical mapping is required. Minimally invasive stereotactic placement of depth electrodes, stereoelectroencephalography (SEEG), has garnered increasing use, but limited data exist to evaluate its postoperative outcomes in the context of the contemporaneous availability of both SEEG and subdural electrode (SDE) monitoring. We aimed to assess the patient experience, surgical intervention, and seizure outcomes associated with these two epileptic focus mapping techniques during a period of rapid adoption of neuromodulatory and ablative epilepsy treatments. METHODS: We retrospectively reviewed 66 consecutive adult intracranial electrode monitoring cases at our institution between 2014 and 2017. Monitoring was performed with either SEEG (n = 47) or SDEs (n = 19). RESULTS: Both groups had high rates of SOZ identification (SEEG 91.5%, SDE 88.2%, P = .69). The majority of patients achieved Engel class I (SEEG 29.3%, SDE 35.3%) or II outcomes (SEEG 31.7%, SDE 29.4%) after epilepsy surgery, with no significant difference between groups (P = .79). SEEG patients reported lower median pain scores (P = .03) and required less narcotic pain medication (median = 94.5 vs 594.6 milligram morphine equivalents, P = .0003). Both groups had low rates of symptomatic hemorrhage (SEEG 0%, SDE 5.3%, P = .11). On multivariate logistic regression, undergoing resection or ablation (vs responsive neurostimulation/vagus nerve stimulation) was the only significant independent predictor of a favorable outcome (adjusted odds ratio = 25.4, 95% confidence interval = 3.48-185.7, P = .001). SIGNIFICANCE: Although both SEEG and SDE monitoring result in favorable seizure control, SEEG has the advantage of superior pain control, decreased narcotic usage, and lack of routine need for intensive care unit stay. Despite a heterogenous collection of epileptic semiologies, seizure outcome was associated with the therapeutic surgical modality and not the intracranial monitoring technique. The potential for an improved postoperative experience makes SEEG a promising method for intracranial electrode monitoring.


Subject(s)
Brain Mapping/methods , Electric Stimulation Therapy , Electrocorticography/methods , Epilepsy/physiopathology , Laser Therapy , Neurosurgical Procedures , Adult , Electroencephalography , Epilepsy/diagnosis , Epilepsy/therapy , Female , Humans , Male , Middle Aged , Prognosis , Prosthesis Implantation/methods , Retrospective Studies , Stereotaxic Techniques , Subdural Space , Treatment Outcome , Vagus Nerve Stimulation , Young Adult
3.
J Neurotrauma ; 37(2): 347-356, 2020 01 15.
Article in English | MEDLINE | ID: mdl-31702476

ABSTRACT

Whereas the diagnosis of moderate and severe traumatic brain injury (TBI) is readily visible on current medical imaging paradigms (magnetic resonance imaging [MRI] and computed tomography [CT] scanning), a far greater challenge is associated with the diagnosis and subsequent management of mild TBI (mTBI), especially concussion which, by definition, is characterized by a normal CT. To investigate whether the integrity of the blood-brain barrier (BBB) is altered in a high-risk population for concussions, we studied professional mixed martial arts (MMA) fighters and adolescent rugby players. Additionally, we performed the linear regression between the BBB disruption defined by increased gadolinium contrast extravasation on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) on MRI and multiple biomechanical parameters indicating the severity of impacts recorded using instrumented mouthguards in professional MMA fighters. MMA fighters were examined pre-fight for a baseline and again within 120 h post-competitive fight, whereas rugby players were examined pre-season and again post-season or post-match in a subset of cases. DCE-MRI, serological analysis of BBB biomarkers, and an analysis of instrumented mouthguard data, was performed. Here, we provide pilot data that demonstrate disruption of the BBB in both professional MMA fighters and rugby players, dependent on the level of exposure. Our data suggest that biomechanical forces in professional MMA and adolescent rugby can lead to BBB disruption. These changes on imaging may serve as a biomarker of exposure of the brain to repetitive subconcussive forces and mTBI.


Subject(s)
Athletes , Blood-Brain Barrier/diagnostic imaging , Brain Concussion/diagnostic imaging , Brain/diagnostic imaging , Adolescent , Adult , Blood-Brain Barrier/pathology , Brain/pathology , Brain Concussion/pathology , Football/injuries , Humans , Magnetic Resonance Imaging , Male , Martial Arts/injuries , Young Adult
4.
Cureus ; 8(12): e919, 2016 Dec 07.
Article in English | MEDLINE | ID: mdl-28083463

ABSTRACT

The authors report a challenging case of a brain metastasis located in the motor cortex, which was not responsive to radiosurgery. Use of a novel technique, magnetic resonance-guided laser-induced thermotherapy (MRgLITT), resulted in the complete obliteration of the lesion without adverse effects or evidence of tumor recurrence at follow-up. This case illustrates that MRgLITT may provide a viable alternative for patients with brain metastases refractory to radiosurgery or in deep locations, where both stereotactic radiosurgery (SRS) and surgical resection may be ineffective.

6.
Nanomedicine ; 8(8): 1355-63, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22370335

ABSTRACT

Gold nanostars offer unique plasmon properties that efficiently transduce photon energy into heat for photothermal therapy. Nanostars, with their small core size and multiple long thin branches, exhibit high absorption cross-sections that are tunable in the near-infrared region with relatively low scattering effect, making them efficient photothermal transducers. Here, we demonstrate particle tracking and photothermal ablation both in vitro and in vivo. Using SKBR3 breast cancer cells incubated with bare nanostars, we observed photothermal ablation within 5 minutes of irradiation (980-nm continuous-wave laser, 15 W/cm2). On a mouse injected systemically with PEGylated nanostars for 2 days, extravasation of nanostars was observed and localized photothermal ablation was demonstrated on a dorsal window chamber within 10 minutes of irradiation (785-nm continuous-wave laser, 1.1 W/cm2). These preliminary results of plasmon-enhanced localized hyperthermia are encouraging and have illustrated the potential of gold nanostars as efficient photothermal agents in cancer therapy. FROM THE CLINICAL EDITOR: Gold nanostars are tunable in the near-infrared region with low scattering, thus enable photothermal therapy. Encouraging preliminary results of plasmon-enhanced localized hyperthermia both in vitro and in vivo demonstrate that Au nanostars may be efficient photothermal agents for cancer therapy.


Subject(s)
Breast Neoplasms/therapy , Gold , Hyperthermia, Induced , Nanoparticles , Animals , Cell Line, Tumor , Female , Gold/chemistry , Gold/therapeutic use , Humans , Mice , Nanoparticles/chemistry , Nanoparticles/therapeutic use , Phototherapy , Surface Plasmon Resonance
7.
Ultrasound Med Biol ; 37(10): 1667-76, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21856073

ABSTRACT

In this study, we investigated the feasibility of using 3.5-Fr intravascular ultrasound (IVUS) catheters for minimally-invasive, image-guided hyperthermia treatment of tumors in the brain. Feasibility was demonstrated by: (1) retro-fitting a commercial 3.5-Fr IVUS catheter with a 5 × 0.5 × 0.22 mm PZT-4 transducer for 9-MHz imaging and (2) testing an identical transducer for therapy potential with 3.3-MHz continuous-wave excitation. The imaging transducer was compared with a 9-Fr, 9-MHz ICE catheter when visualizing the post-mortem ovine brain and was also used to attempt vascular access to an in vivo porcine brain. A net average electrical power input of 700 mW was applied to the therapy transducer, producing a temperature rise of +13.5°C at a depth of 1.5 mm in live brain tumor tissue in the mouse model. These results suggest that it may be feasible to combine the imaging and therapeutic capabilities into a single device as a clinically-viable instrument.


Subject(s)
Brain Neoplasms/therapy , Glioblastoma/therapy , Hyperthermia, Induced/instrumentation , Surgery, Computer-Assisted/instrumentation , Transducers , Ultrasonography, Interventional/instrumentation , Animals , Cerebral Angiography , Disease Models, Animal , Equipment Design , Feasibility Studies , Mice , Mice, Nude , Phantoms, Imaging , Sheep, Domestic , Swine
8.
Article in English | MEDLINE | ID: mdl-21041144

ABSTRACT

In this study, we investigated the feasibility of modifying 3-Fr IVUS catheters in several designs to potentially achieve minimally-invasive, endovascular access for image-guided ultrasound hyperthermia treatment of tumors in the brain. Using a plane wave approximation, target frequencies of 8.7 and 3.5 MHz were considered optimal for heating at depths (tumor sizes) of 1 and 2.5 cm, respectively. First, a 3.5-Fr IVUS catheter with a 0.7-mm diameter transducer (30 MHz nominal frequency) was driven at 8.6 MHz. Second, for a low-frequency design, a 220-µm-thick, 0.35 x 0.35-mm PZT-4 transducer--driven at width-mode resonance of 3.85 MHz--replaced a 40-MHz element in a 3.5-Fr coronary imaging catheter. Third, a 5 x 0.5-mm PZT-4 transducer was evaluated as the largest aperture geometry possible for a flexible 3-Fr IVUS catheter. Beam plots and on-axis heating profiles were simulated for each aperture, and test transducers were fabricated. The electrical impedance, impulse response, frequency response, maximum intensity, and mechanical index were measured to assess performance. For the 5 x 0.5-mm transducer, this testing also included mechanically scanning and reconstructing an image of a 2.5-cm-diameter cyst phantom as a preliminary measure of imaging potential.


Subject(s)
Equipment Design , Hyperthermia, Induced/methods , Surgery, Computer-Assisted/instrumentation , Transducers , Ultrasonography, Interventional/instrumentation , Brain/blood supply , Catheters , Computer Simulation , Cysts/diagnostic imaging , Feasibility Studies , Humans , Hyperthermia, Induced/instrumentation , Models, Theoretical , Phantoms, Imaging
9.
Ultrason Imaging ; 31(2): 81-100, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19630251

ABSTRACT

In this study, we investigated the feasibility of an intracranial catheter transducer with dual-mode capability of real-time 3D (RT3D) imaging and ultrasound hyperthermia, for application in the visualization and treatment of tumors in the brain. Feasibility is demonstrated in two ways: first by using a 50-element linear array transducer (17 mm x 3.1 mm aperture) operating at 4.4 MHz with our Volumetrics diagnostic scanner and custom, electrical impedance-matching circuits to achieve a temperature rise over 4 degrees C in excised pork muscle, and second, by designing and constructing a 12 Fr, integrated matrix and linear-array catheter transducer prototype for combined RT3D imaging and heating capability. This dual-mode catheter incorporated 153 matrix array elements and 11 linear array elements diced on a 0.2 mm pitch, with a total aperture size of 8.4 mm x 2.3 mm. This 3.64 MHz array achieved a 3.5 degrees C in vitro temperature rise at a 2 cm focal distance in tissue-mimicking material. The dual-mode catheter prototype was compared with a Siemens 10 Fr AcuNav catheter as a gold standard in experiments assessing image quality and therapeutic potential and both probes were used in an in vivo canine brain model to image anatomical structures and color Doppler blood flow and to attempt in vivo heating.


Subject(s)
Brain Neoplasms/therapy , Catheterization/methods , Hyperthermia, Induced/methods , Imaging, Three-Dimensional/methods , Ultrasonography, Doppler, Color/methods , Ultrasonography, Interventional/methods , Animals , Brain Neoplasms/diagnostic imaging , Catheterization/instrumentation , Dogs , Equipment Design , Feasibility Studies , Hyperthermia, Induced/instrumentation , Imaging, Three-Dimensional/instrumentation , Phantoms, Imaging , Swine , Transducers , Ultrasonography, Doppler, Color/instrumentation , Ultrasonography, Interventional/instrumentation
10.
Pediatr Neurosurg ; 45(3): 225-9, 2009.
Article in English | MEDLINE | ID: mdl-19521137

ABSTRACT

Hypothalamic hamartomas (HHs) are congenital, benign masses in the hypothalamus and tuber cinereum that may cause central precocious puberty and gelastic seizures. Nodules of small neurons are thought to be a universal feature of the microarchitecture of HH lesions associated with epilepsy. Here we describe the case of a 5-year-old boy with gelastic seizures who underwent resection of a HH that contained nodules of glial cells, but only few, randomly distributed neurons. HHs that contain few or no neurons have only been reported thus far in cases associated with precocious puberty. This case demonstrates that few solitary neurons in HHs can drive the development of gelastic seizures, and nodules of small neurons may not be a universal feature of HHs associated with epilepsy. This finding is clinically important since hypothalamic hamartomas with rare neurons can easily be misdiagnosed as pilocytic astrocytomas or subependymomas if their presence is overlooked. A neuronal stain is helpful in making the correct diagnosis in these cases.


Subject(s)
Epilepsies, Partial/etiology , Epilepsies, Partial/pathology , Hamartoma/complications , Hamartoma/pathology , Hypothalamic Diseases/complications , Hypothalamic Diseases/pathology , Biopsy , Child, Preschool , Humans , Hypothalamus/pathology , Magnetic Resonance Imaging , Male , Neurons/pathology
SELECTION OF CITATIONS
SEARCH DETAIL