Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Neurology ; 95(9): e1244-e1256, 2020 09 01.
Article in English | MEDLINE | ID: mdl-32690786

ABSTRACT

OBJECTIVE: To prospectively evaluate safety and efficacy of brain-responsive neurostimulation in adults with medically intractable focal onset seizures (FOS) over 9 years. METHODS: Adults treated with brain-responsive neurostimulation in 2-year feasibility or randomized controlled trials were enrolled in a long-term prospective open label trial (LTT) to assess safety, efficacy, and quality of life (QOL) over an additional 7 years. Safety was assessed as adverse events (AEs), efficacy as median percent change in seizure frequency and responder rate, and QOL with the Quality of Life in Epilepsy (QOLIE-89) inventory. RESULTS: Of 256 patients treated in the initial trials, 230 participated in the LTT. At 9 years, the median percent reduction in seizure frequency was 75% (p < 0.0001, Wilcoxon signed rank), responder rate was 73%, and 35% had a ≥90% reduction in seizure frequency. We found that 18.4% (47 of 256) experienced ≥1 year of seizure freedom, with 62% (29 of 47) seizure-free at the last follow-up and an average seizure-free period of 3.2 years (range 1.04-9.6 years). Overall QOL and epilepsy-targeted and cognitive domains of QOLIE-89 remained significantly improved (p < 0.05). There were no serious AEs related to stimulation, and the sudden unexplained death in epilepsy (SUDEP) rate was significantly lower than predefined comparators (p < 0.05, 1-tailed χ2). CONCLUSIONS: Adjunctive brain-responsive neurostimulation provides significant and sustained reductions in the frequency of FOS with improved QOL. Stimulation was well tolerated; implantation-related AEs were typical of other neurostimulation devices; and SUDEP rates were low. CLINICALTRIALSGOV IDENTIFIER: NCT00572195. CLASSIFICATION OF EVIDENCE: This study provides Class IV evidence that brain-responsive neurostimulation significantly reduces focal seizures with acceptable safety over 9 years.


Subject(s)
Drug Resistant Epilepsy/therapy , Electric Stimulation Therapy/methods , Epilepsies, Partial/therapy , Implantable Neurostimulators , Quality of Life , Adolescent , Adult , Aged , Depressive Disorder/epidemiology , Drug Resistant Epilepsy/physiopathology , Drug Resistant Epilepsy/psychology , Epilepsies, Partial/physiopathology , Epilepsies, Partial/psychology , Female , Follow-Up Studies , Humans , Intracranial Hemorrhages/epidemiology , Male , Memory Disorders/epidemiology , Middle Aged , Prospective Studies , Prosthesis-Related Infections/epidemiology , Randomized Controlled Trials as Topic , Status Epilepticus/epidemiology , Sudden Unexpected Death in Epilepsy/epidemiology , Suicide/statistics & numerical data , Treatment Outcome , Young Adult
2.
Epilepsia ; 61(8): 1749-1757, 2020 08.
Article in English | MEDLINE | ID: mdl-32658325

ABSTRACT

OBJECTIVE: The RNS System is a direct brain-responsive neurostimulation system that is US Food and Drug Administration-approved for adults with medically intractable focal onset seizures based on safety and effectiveness data from controlled clinical trials. The purpose of this study was to retrospectively evaluate the real-world safety and effectiveness of the RNS System. METHODS: Eight comprehensive epilepsy centers conducted a chart review of patients treated with the RNS System for at least 1 year, in accordance with the indication for use. Data included device-related serious adverse events and the median percent change in disabling seizure frequency from baseline at years 1, 2, and 3 of treatment and at the most recent follow-up. RESULTS: One hundred fifty patients met the criteria for analysis. The median reduction in seizures was 67% (interquartile range [IQR] = 33%-93%, n = 149) at 1 year, 75% (IQR = 50%-94%, n = 93) at 2 years, 82% (IQR = 50%-96%, n = 38) at ≥3 years, and 74% (IQR = 50%-96%, n = 150) at last follow-up (mean = 2.3 years). Thirty-five percent of patients had a ≥90% seizure frequency reduction, and 18% of patients reported being clinically seizure-free at last follow-up. Seizure frequency reductions were similar regardless of patient age, age at epilepsy onset, duration of epilepsy, seizure onset in mesial temporal or neocortical foci, magnetic resonance imaging findings, prior intracranial monitoring, prior epilepsy surgery, or prior vagus nerve stimulation treatment. The infection rate per procedure was 2.9% (6/150 patients); five of the six patients had an implant site infection, and one had osteomyelitis. Lead revisions were required in 2.7% (4/150), and 2.0% (3/150) of patients had a subdural hemorrhage, none of which had long-lasting neurological consequences. SIGNIFICANCE: In this real-world experience, safety was similar and clinical seizure outcomes exceeded those of the prospective clinical trials, corroborating effectiveness of this therapy and suggesting that clinical experience has informed more effective programming.


Subject(s)
Drug Resistant Epilepsy/therapy , Electric Stimulation Therapy/methods , Epilepsies, Partial/therapy , Implantable Neurostimulators , Adolescent , Adult , Aged , Electrocorticography , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome , Young Adult
3.
Epilepsia ; 61(3): 408-420, 2020 03.
Article in English | MEDLINE | ID: mdl-32072621

ABSTRACT

OBJECTIVE: To describe seizure outcomes in patients with medically refractory epilepsy who had evidence of bilateral mesial temporal lobe (MTL) seizure onsets and underwent MTL resection based on chronic ambulatory intracranial EEG (ICEEG) data from a direct brain-responsive neurostimulator (RNS) system. METHODS: We retrospectively identified all patients at 17 epilepsy centers with MTL epilepsy who were treated with the RNS System using bilateral MTL leads, and in whom an MTL resection was subsequently performed. Presumed lateralization based on routine presurgical approaches was compared to lateralization determined by RNS System chronic ambulatory ICEEG recordings. The primary outcome was frequency of disabling seizures at last 3-month follow-up after MTL resection compared to seizure frequency 3 months before MTL resection. RESULTS: We identified 157 patients treated with the RNS System with bilateral MTL leads due to presumed bitemporal epilepsy. Twenty-five patients (16%) subsequently had an MTL resection informed by chronic ambulatory ICEEG (mean = 42 months ICEEG); follow-up was available for 24 patients. After MTL resection, the median reduction in disabling seizures at last follow-up was 100% (mean: 94%; range: 50%-100%). Nine patients (38%) had exclusively unilateral electrographic seizures recorded by chronic ambulatory ICEEG and all were seizure-free at last follow-up after MTL resection; eight of nine continued RNS System treatment. Fifteen patients (62%) had bilateral MTL electrographic seizures, had an MTL resection on the more active side, continued RNS System treatment, and achieved a median clinical seizure reduction of 100% (mean: 90%; range: 50%-100%) at last follow-up, with eight of fifteen seizure-free. For those with more than 1 year of follow-up (N = 21), 15 patients (71%) were seizure-free during the most recent year, including all eight patients with unilateral onsets and 7 of 13 patients (54%) with bilateral onsets. SIGNIFICANCE: Chronic ambulatory ICEEG data provide information about lateralization of MTL seizures and can identify additional patients who may benefit from MTL resection.


Subject(s)
Anterior Temporal Lobectomy/methods , Drug Resistant Epilepsy/surgery , Epilepsy, Temporal Lobe/surgery , Temporal Lobe/surgery , Adult , Aged , Drug Resistant Epilepsy/physiopathology , Electric Stimulation Therapy , Electrocorticography , Epilepsy, Temporal Lobe/physiopathology , Female , Humans , Implantable Neurostimulators , Male , Middle Aged , Monitoring, Ambulatory , Neurosurgical Procedures , Retrospective Studies , Treatment Outcome , Young Adult
4.
Epilepsia ; 59(6): 1198-1207, 2018 06.
Article in English | MEDLINE | ID: mdl-29600809

ABSTRACT

OBJECTIVE: To compare stereotactic radiosurgery (SRS) versus anterior temporal lobectomy (ATL) for patients with pharmacoresistant unilateral mesial temporal lobe epilepsy (MTLE). METHODS: This randomized, single-blinded, controlled trial recruited adults eligible for open surgery among 14 centers in the USA, UK, and India. Treatment was either SRS at 24 Gy to the 50% isodose targeting mesial structures, or standardized ATL. Outcomes were seizure remission (absence of disabling seizures between 25 and 36 months), verbal memory (VM), and quality of life (QOL) at 36-month follow-up. RESULTS: A total of 58 patients (31 in SRS, 27 in ATL) were treated. Sixteen (52%) SRS and 21 (78%) ATL patients achieved seizure remission (difference between ATL and SRS = 26%, upper 1-sided 95% confidence interval = 46%, P value at the 15% noninferiority margin = .82). Mean VM changes from baseline for 21 English-speaking, dominant-hemisphere patients did not differ between groups; consistent worsening occurred in 36% of SRS and 57% of ATL patients. QOL improved with seizure remission. Adverse events were anticipated cerebral edema and related symptoms for some SRS patients, and cerebritis, subdural hematoma, and others for ATL patients. SIGNIFICANCE: These data suggest that ATL has an advantage over SRS in terms of proportion of seizure remission, and both SRS and ATL appear to have effectiveness and reasonable safety as treatments for MTLE. SRS is an alternative to ATL for patients with contraindications for or with reluctance to undergo open surgery.


Subject(s)
Anterior Temporal Lobectomy/methods , Epilepsy, Temporal Lobe/radiotherapy , Epilepsy, Temporal Lobe/surgery , Radiosurgery/methods , Adult , Dose-Response Relationship, Radiation , Drug Resistant Epilepsy/radiotherapy , Drug Resistant Epilepsy/surgery , Epilepsy, Temporal Lobe/complications , Epilepsy, Temporal Lobe/psychology , Female , Functional Laterality , Humans , Longitudinal Studies , Male , Memory Disorders/diagnosis , Memory Disorders/etiology , Middle Aged , Postoperative Complications/diagnosis , Quality of Life , Single-Blind Method , Treatment Outcome , Vision Disorders/diagnosis , Vision Disorders/etiology
5.
Epilepsia ; 58(6): 994-1004, 2017 06.
Article in English | MEDLINE | ID: mdl-28398014

ABSTRACT

OBJECTIVE: Evaluate the seizure-reduction response and safety of mesial temporal lobe (MTL) brain-responsive stimulation in adults with medically intractable partial-onset seizures of mesial temporal lobe origin. METHODS: Subjects with mesial temporal lobe epilepsy (MTLE) were identified from prospective clinical trials of a brain-responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2-6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events. RESULTS: There were 111 subjects with MTLE; 72% of subjects had bilateral MTL onsets and 28% had unilateral onsets. Subjects had one to four leads placed; only two leads could be connected to the device. Seventy-six subjects had depth leads only, 29 had both depth and strip leads, and 6 had only strip leads. The mean follow-up was 6.1 ± (standard deviation) 2.2 years. The median percent seizure reduction was 70% (last observation carried forward). Twenty-nine percent of subjects experienced at least one seizure-free period of 6 months or longer, and 15% experienced at least one seizure-free period of 1 year or longer. There was no difference in seizure reduction in subjects with and without mesial temporal sclerosis (MTS), bilateral MTL onsets, prior resection, prior intracranial monitoring, and prior vagus nerve stimulation. In addition, seizure reduction was not dependent on the location of depth leads relative to the hippocampus. The most frequent serious device-related adverse event was soft tissue implant-site infection (overall rate, including events categorized as device-related, uncertain, or not device-related: 0.03 per implant year, which is not greater than with other neurostimulation devices). SIGNIFICANCE: Brain-responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including patients with unilateral or bilateral MTLE who are not candidates for temporal lobectomy or who have failed a prior MTL resection.


Subject(s)
Brain/physiopathology , Deep Brain Stimulation/methods , Drug Resistant Epilepsy/physiopathology , Drug Resistant Epilepsy/therapy , Electric Stimulation Therapy/methods , Electroencephalography , Epilepsies, Partial/physiopathology , Epilepsies, Partial/therapy , Epilepsy, Temporal Lobe/physiopathology , Epilepsy, Temporal Lobe/therapy , Adolescent , Adult , Dominance, Cerebral/physiology , Electrodes, Implanted , Feasibility Studies , Female , Follow-Up Studies , Humans , Long-Term Care , Male , Middle Aged , Young Adult
6.
Epilepsia ; 58(6): 1005-1014, 2017 06.
Article in English | MEDLINE | ID: mdl-28387951

ABSTRACT

OBJECTIVE: Evaluate the seizure-reduction response and safety of brain-responsive stimulation in adults with medically intractable partial-onset seizures of neocortical origin. METHODS: Patients with partial seizures of neocortical origin were identified from prospective clinical trials of a brain-responsive neurostimulator (RNS System, NeuroPace). The seizure reduction over years 2-6 postimplantation was calculated by assessing the seizure frequency compared to a preimplantation baseline. Safety was assessed based on reported adverse events. Additional analyses considered safety and seizure reduction according to lobe and functional area (e.g., eloquent cortex) of seizure onset. RESULTS: There were 126 patients with seizures of neocortical onset. The average follow-up was 6.1 implant years. The median percent seizure reduction was 70% in patients with frontal and parietal seizure onsets, 58% in those with temporal neocortical onsets, and 51% in those with multilobar onsets (last observation carried forward [LOCF] analysis). Twenty-six percent of patients experienced at least one seizure-free period of 6 months or longer and 14% experienced at least one seizure-free period of 1 year or longer. Patients with lesions on magnetic resonance imaging (MRI; 77% reduction, LOCF) and those with normal MRI findings (45% reduction, LOCF) benefitted, although the treatment response was more robust in patients with an MRI lesion (p = 0.02, generalized estimating equation [GEE]). There were no differences in the seizure reduction in patients with and without prior epilepsy surgery or vagus nerve stimulation. Stimulation parameters used for treatment did not cause acute or chronic neurologic deficits, even in eloquent cortical areas. The rates of infection (0.017 per patient implant year) and perioperative hemorrhage (0.8%) were not greater than with other neurostimulation devices. SIGNIFICANCE: Brain-responsive stimulation represents a safe and effective treatment option for patients with medically intractable epilepsy, including adults with seizures of neocortical onset, and those with onsets from eloquent cortex.


Subject(s)
Cerebral Cortex/physiopathology , Deep Brain Stimulation/methods , Drug Resistant Epilepsy/physiopathology , Drug Resistant Epilepsy/therapy , Electric Stimulation Therapy/methods , Electroencephalography , Neocortex/physiopathology , Adolescent , Adult , Brain Mapping , Deep Brain Stimulation/instrumentation , Electric Stimulation Therapy/instrumentation , Electrodes, Implanted , Epilepsies, Partial/physiopathology , Epilepsies, Partial/therapy , Epilepsy, Complex Partial/physiopathology , Epilepsy, Complex Partial/therapy , Epilepsy, Partial, Motor/physiopathology , Epilepsy, Partial, Motor/therapy , Epilepsy, Tonic-Clonic/physiopathology , Epilepsy, Tonic-Clonic/therapy , Feasibility Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Young Adult
7.
World Neurosurg ; 84(3): 719-26, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25940211

ABSTRACT

INTRODUCTION: The clinical results for the RNS System (NeuroPace, Mountain View, California, USA) closed-loop responsive neurostimulator for the treatment of medically intractable partial-onset seizures have been encouraging. The University of Southern California (USC) Neurorestoration Center and the Keck Hospital of USC have become the world's first institutions to implant an RNS System post U.S. Food and Drug Administration (FDA) approval. As one of the study centers, we review our experience with our group of patients who have been implanted with the RNS System. METHODS: A total of 40 surgeries by a single surgeon were performed on 10 patients (7 male and 3 female) with an average age of 39.2 years (24-66 years) and were followed for an average of 45 months (30-54 months). The average age at seizure onset was 14 years (birth-37 years) with an average of 4.7 (3-12) failed antiepileptic drugs. We reviewed the patients' charts for complications from the surgeries including infections requiring surgical intervention, hematomas, hardware failures, and death. RESULTS: Of the 40 surgeries, there were 10 initial implantations of the neurostimulator and leads, 24 neurostimulator replacements for expected end of neurostimulator service, 2 incision and drainage procedures (I & Ds) for soft tissue infection followed by 1 explantation and 1 reimplantation (same patient), and 2 revisions because of one lead that was damaged at the exit point between the skull and a titanium mesh and the second lead that was damaged at an acute bend over the skull (same patient). Eight of the patients had no complications and underwent an average of 2.7 neurostimulator replacements over 7 consecutive years to date. Each patient underwent routine postoperative computed tomography imaging of the brain, and none had any intracranial hematomas or misplaced leads requiring revision surgery. Finally, there were no deaths in our patient population. CONCLUSIONS: Our experience with the NeuroPace RNS System over an average follow-up of 45 months suggests that the surgery and device are safe when placed by an experienced surgeon. Although there were no clinically significant hematomas or patient deaths, we did have 1 patient each with infection and lead damage at the point of exit from the skull. We compare the results of this study with other neuromodulation procedures for epilepsy to evaluate the safety and complications associated with the RNS System. Our initial experience suggests that the RNS System can be readily incorporated into an active epilepsy surgical center.


Subject(s)
Electric Stimulation Therapy/instrumentation , Epilepsies, Partial/therapy , Adult , Aged , Drug Resistance , Electric Stimulation Therapy/adverse effects , Electric Stimulation Therapy/methods , Electrodes, Implanted , Equipment Failure , Female , Follow-Up Studies , Functional Laterality , Humans , Male , Middle Aged , Neurosurgical Procedures , Retrospective Studies , Stereotaxic Techniques , Surgical Wound Infection/therapy , Treatment Outcome , Young Adult
8.
Epilepsia ; 55(3): 432-41, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24621228

ABSTRACT

OBJECTIVE: To demonstrate the safety and effectiveness of responsive stimulation at the seizure focus as an adjunctive therapy to reduce the frequency of seizures in adults with medically intractable partial onset seizures arising from one or two seizure foci. METHODS: Randomized multicenter double-blinded controlled trial of responsive focal cortical stimulation (RNS System). Subjects with medically intractable partial onset seizures from one or two foci were implanted, and 1 month postimplant were randomized 1:1 to active or sham stimulation. After the fifth postimplant month, all subjects received responsive stimulation in an open label period (OLP) to complete 2 years of postimplant follow-up. RESULTS: All 191 subjects were randomized. The percent change in seizures at the end of the blinded period was -37.9% in the active and -17.3% in the sham stimulation group (p = 0.012, Generalized Estimating Equations). The median percent reduction in seizures in the OLP was 44% at 1 year and 53% at 2 years, which represents a progressive and significant improvement with time (p < 0.0001). The serious adverse event rate was not different between subjects receiving active and sham stimulation. Adverse events were consistent with the known risks of an implanted medical device, seizures, and of other epilepsy treatments. There were no adverse effects on neuropsychological function or mood. SIGNIFICANCE: Responsive stimulation to the seizure focus reduced the frequency of partial-onset seizures acutely, showed improving seizure reduction over time, was well tolerated, and was acceptably safe. The RNS System provides an additional treatment option for patients with medically intractable partial-onset seizures.


Subject(s)
Electric Stimulation Therapy/trends , Epilepsies, Partial/diagnosis , Epilepsies, Partial/therapy , Implantable Neurostimulators/trends , Adolescent , Adult , Aged , Double-Blind Method , Electric Stimulation Therapy/instrumentation , Electric Stimulation Therapy/methods , Epilepsies, Partial/physiopathology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Quality of Life/psychology , Time Factors , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL