Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Clin Genitourin Cancer ; 22(2): 244-251, 2024 04.
Article in English | MEDLINE | ID: mdl-38155081

ABSTRACT

CONTEXT: Despite negative preoperative conventional imaging, up to 10% of patients with prostate cancer (PCa) harbor lymph-node involvement (LNI) at radical prostatectomy (RP). The advent of more accurate imaging modalities such as PET/CT improved the detection of LNI. However, their clinical impact and prognostic value are still unclear. We aimed to investigate the prognostic value of preoperative PET/CT in patients node positive (pN+) at RP. EVIDENCE SYNTHESIS: We retrospectively identified cN0M0 patients at conventional imaging (CT and/or MRI, and bone scan) who had pN+ PCa at RP at 17 referral centers. Patients with cN+ at PSMA/Choline PET/CT but cN0M0 at conventional imaging were also included. Systemic progression/recurrence was the primary outcome; Cox proportional hazards models were used for multivariate analysis. EVIDENCE ACQUISITION: We included 1163 pN+ men out of whom 95 and 100 had preoperative PSMA and/or Choline PET/CT, respectively. ISUP grade ≥4 was detected in 66.6%. Overall, 42% of patients had postoperative PSA persistence (≥0.1 ng/mL). Postoperative management included initial observation (34%), ADT (22.7%) and adjuvant RT+/-ADT (42.8%). Median follow-up was 42 months. Patients with cN+ on PSMA PET/CT had an increased risk of systemic progression (52.9% vs. 13.6% cN0 PSMA PET/CT vs. 21.5% cN0 at conventional imaging; P < .01). This held true at multivariable analysis: (HR 6.184, 95% CI: 3.386-11-295; P < .001) whilst no significant results were highlighted for Choline PET/CT. No significant associations for both PET types were found for local progression, BCR, and overall mortality (all P > .05). Observation as an initial management strategy instead of adjuvant treatments was related with an increased risk of metastases (HR 1.808; 95% CI: 1.069-3.058; P < .05). CONCLUSIONS: PSMA PET/CT cN+ patients with negative conventional imaging have an increased risk of systemic progression after RP compared to their counterparts with cN0M0 disease both at conventional and/or molecular imaging.


Subject(s)
Positron Emission Tomography Computed Tomography , Prostatic Neoplasms , Male , Humans , Positron Emission Tomography Computed Tomography/methods , Prognosis , Retrospective Studies , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Prostatectomy , Choline , Gallium Radioisotopes
2.
World J Urol ; 38(3): 741-746, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31087122

ABSTRACT

PURPOSE: To investigate the outcomes of comparative studies on photoselective vaporization of the prostate (PVP) as a function of risk of bias (RoB), conflicts of interest (COI), and industrial sponsorship (IS). METHODS: We performed a systematic literature search for comparative studies on PVP [randomized controlled trials (RCTs) and non-randomized comparative studies (NRCSs)]. Study selection as well as comprehensive assessment of RoB, COIs, and IS were performed in duplicate. The identified studies were further rated by two independent board-certified urologists as either PVP-favourable or PVP-unfavourable. Descriptive statistics were performed among all identified studies and among the subgroups of studies rated as favourable and unfavourable, respectively. RESULTS: Sixty-five studies qualified for inclusion (25 RTCs and 40 NRCSs) of which 56 (86%) were rated favourable and 9 (14%) unfavourable. A majority of all studies mentioned the absence/presence of potential COIs (78%). In contrast, a sponsorship statement was only found in 29% of the investigations. Studies rated favourable demonstrated a higher percentage of COIs (39% versus 22%). IS was exclusively found among favourable studies. Furthermore, a serious or critical RoB was more often found in favourably rated NRCSs. CONCLUSIONS: COIs and IS seem to be associated with favourable study outcomes in comparative studies on PVP. The transparency of the whole research process from study conception to the dissemination of the results has to be further improved to prevent a harmful effect of COIs and IS on the internal validity of studies.


Subject(s)
Conflict of Interest , Laser Therapy , Lower Urinary Tract Symptoms/surgery , Prostatic Hyperplasia/surgery , Research Support as Topic , Transurethral Resection of Prostate , Bias , Disclosure , Health Care Sector , Humans , Lower Urinary Tract Symptoms/etiology , Male , Prostatic Hyperplasia/complications
3.
J Endourol ; 33(2): 107-112, 2019 02.
Article in English | MEDLINE | ID: mdl-30612441

ABSTRACT

INTRODUCTION AND OBJECTIVES: Bipolar plasma vaporization (BPV) has been shown to be a low-morbidity alternative to conventional transurethral resection of the prostate (TURP). Improved functional short-term outcome and a postoperative prostate volume reduction comparable to TURP have been reported. However, comprehensive mid- or long-term results following BPV are still lacking. METHODS: A consecutive series of men who underwent pure BPV in a tertiary care academic center was prospectively investigated. Clinical parameters [International Prostate Symptom Score with Quality-of-Life domain, peak urinary flow rate (Qmax), postvoid residual volume, and prostate-specific antigen] as well as prostate volume (assessed by planimetric volumetry following transrectal 3D-ultrasound) were recorded preoperatively and regularly after BPV (after catheter removal, 6 weeks, 6 months, 1 year, and 3 years). Statistical analysis was performed using the Wilcoxon signed-rank test. All p-values ≤0.05 were considered significant. RESULTS: Seventy-five men were included in this prospective investigation. Their median (interquartile range) prostate volume was 41.0 mL (30.6-57.4 mL). In the first year after BPV, the prostate volume continuously decreased over time and the relative volume reduction was 52.2% after 12 months. Subsequently, the volume reduction remained stable with 50.7% after 3 years. All investigated outcome parameters improved significantly after the procedure and remained so after 3 years. Reoperations due to persistent or regrown adenoma were not necessary. Six (8.0%) and five patients (6.6%) developed a de novo urethral stricture or bladder neck contracture, respectively. CONCLUSIONS: Three years after pure BPV of the prostate, a durable prostate volume reduction in combination with a stable improvement of functional outcome parameters was detectable in our prospective study. The low morbidity of the procedure and the possibility to perform BPV under ongoing platelet aggregation inhibition confirms its role as minimally invasive alternative to conventional TURP.


Subject(s)
Electrosurgery , Prostatic Hyperplasia/surgery , Aged , Humans , Kallikreins/blood , Male , Middle Aged , Minimally Invasive Surgical Procedures , Postoperative Complications , Prospective Studies , Prostate-Specific Antigen/blood , Prostatic Hyperplasia/blood , Quality of Life , Treatment Outcome , Volatilization
4.
World J Urol ; 35(3): 429-435, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27339623

ABSTRACT

PURPOSE: To evaluate and compare postoperative changes in prostate volume and clinical outcome after bipolar plasma vaporization (BPV) and conventional transurethral resection of the prostate (TURP). PATIENTS AND METHODS: Consecutive series of patients undergoing BPV or TURP were included in this prospective, nonrandomized study. Planimetric volumetry after transrectal three-dimensional ultrasound of the prostate was performed preoperatively and postoperatively after 6 weeks, 6 months and 12 months. Additionally, changes in clinical outcome parameters were assessed and compared between the groups. The reduction ratio and analysis of covariance were used to compare volume changes between BPV and TURP. Multiple regression analysis was performed to assess a possible interaction between preoperative prostate volume and effect of therapy. RESULTS: A total of 157 patients were included (BPV: n = 68, TURP: n = 89). Median preoperative prostate volume was 43.1 ml in the BPV group and 45.9 ml in the TURP group (p = 0.43). Postoperatively, the prostate volumes decreased significantly in both groups. After catheter removal, the relative residual prostate volume was significantly higher in the BPV group (66.6 vs. 60.8 %; p = 0.02). Thereafter, significant differences were not detectable anymore (12 months: 46.6 vs. 47.1 %; p = 0.82). Regression analysis revealed that tissue ablation after BPV was superior to TURP in prostates <45 ml but inferior in prostates >45 ml. All clinical outcome parameters improved significantly and were not significantly different between the groups. CONCLUSIONS: Volume reduction and short-term clinical outcome following pure BPV was excellent and comparable to conventional TURP. However, volume reduction seems to be limited in patients with larger prostates.


Subject(s)
Electrosurgery/methods , Prostatic Hyperplasia/surgery , Transurethral Resection of Prostate/methods , Urinary Bladder Neck Obstruction/surgery , Aged , Aged, 80 and over , Endosonography , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Organ Size , Prospective Studies , Prostate/diagnostic imaging , Prostate/pathology , Prostate/surgery , Prostatic Hyperplasia/complications , Regression Analysis , Urinary Bladder Neck Obstruction/etiology
5.
World J Urol ; 34(10): 1481-90, 2016 Oct.
Article in English | MEDLINE | ID: mdl-26931560

ABSTRACT

PURPOSE: To evaluate whether the rate of Gleason score (GS) upgrade on final pathology, the rate of positive surgical margins (PSM) and the rate of biochemical recurrence (BCR) after radical prostatectomy (RP) were different if prostate biopsy (PB) was graded by community pathologists (CP) as compared to specialized uro-pathologists (UP). METHODS: A consecutive series of patients undergoing RP in our institution between 2005 and 2013 were retrospectively reviewed. Any GS higher or lower in RP specimen as compared to PB GS was defined as GS upgrade or downgrade, respectively. Additionally, stratification for the new ISUP 2014 grading system was performed. Predictors of GS upgrade and PSMs and prognostic parameters for BCR were assessed by stepwise logistic regression models and by multivariable Cox regression analyses, respectively. RESULTS: A total of 786 patients were available for analysis, and median follow-up was 36 months (1-101 months). A GS upgrade was found in 345 patients (43.9 %) and a GS downgrade in 91 patients (11.6 %). Discordance between PB GS and RP GS was significantly more frequent when grading had been performed by a CP (50.5 % upgrade, 9.0 % downgrade) than by a UP (33.1 % upgrade, 15.7 % downgrade, p < 0.001). CP evaluation was an independent predictor for GS upgrade (odds ratio [OR] 1.91, p < 0.001) and for PSMs (OR 1.69, p = 0.003), as well as an independent predictor of BCR (hazard ratio [HR] 1.65, p = 0.028). CONCLUSIONS: Pathologic evaluation of PBs by a dedicated UP should be recommended to reduce the rate of biopsy undergrading, PSM and BCR after RP.


Subject(s)
Image-Guided Biopsy/methods , Magnetic Resonance Imaging/methods , Neoplasm Grading , Prostate/pathology , Prostatic Neoplasms/diagnosis , Robotics/methods , Transurethral Resection of Prostate/methods , Academic Medical Centers , Aged , Biomarkers, Tumor/blood , Community Health Centers , Follow-Up Studies , Humans , Male , Middle Aged , Prognosis , Prostate-Specific Antigen/blood , Prostatic Neoplasms/blood , Prostatic Neoplasms/surgery , Reproducibility of Results , Retrospective Studies , Switzerland
6.
J Urol ; 193(1): 211-6, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25108273

ABSTRACT

PURPOSE: Absorption of irrigation fluid was not detected during GreenLight™ laser vaporization of the prostate using the first generation 80 W laser. However, data are lacking on intraoperative irrigation fluid absorption using the second generation 120 W high power laser. We assessed whether fluid absorption occurs during high power laser vaporization of the prostate. MATERIALS AND METHODS: We performed this prospective investigation at a tertiary referral center in patients undergoing 120 W laser vaporization for prostatic bladder outlet obstruction. Normal saline containing 1% ethanol was used for intraoperative irrigation. The expired breath ethanol concentration was measured periodically during the operation using an alcometer. The volume of saline absorption was calculated from these concentrations. Intraoperative changes in hematological and biochemical blood parameters were also recorded. RESULTS: Of 50 investigated patients 22 (44%) had a positive breath ethanol test. Median absorption volume in the absorber group was 725 ml (range 138 to 3,452). Ten patients absorbed more than 1,000 ml. Absorbers had a smaller prostate, more capsular perforation, higher bleeding intensity and more laser energy applied during the operation. Three patients (13%) had symptoms potentially related to fluid absorption. Hemoglobin, hematocrit and serum chloride were the only blood parameters that changed significantly in the absorber group. The changes were significantly different than those in nonabsorbers. CONCLUSIONS: Fluid absorption occurs frequently during high power laser vaporization of the prostate. This should be considered in patients who present with cardiopulmonary or neurological symptoms during or after the procedure.


Subject(s)
Absorption, Physiological , Ethanol/pharmacokinetics , Intraoperative Care/adverse effects , Intraoperative Complications/etiology , Laser Therapy , Sodium Chloride/pharmacokinetics , Transurethral Resection of Prostate/methods , Urinary Bladder Neck Obstruction/surgery , Aged , Aged, 80 and over , Ethanol/administration & dosage , Humans , Male , Middle Aged , Prospective Studies , Sodium Chloride/administration & dosage , Therapeutic Irrigation/adverse effects
7.
World J Urol ; 32(5): 1267-74, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24173627

ABSTRACT

PURPOSE: To assess and compare postoperative prostate volume changes following 532-nm laser vaporization (LV) and transurethral resection of the prostate (TURP). To investigate whether differences in volume reduction are associated with differences in clinical outcome. METHODS: In this prospective, non-randomized study, 184 consecutive patients undergoing 120 W LV (n = 98) or TURP (n = 86) were included. Transrectal three-dimensional ultrasound and planimetric volumetry of the prostate were performed preoperatively, after catheter removal, 6 weeks, 6 and 12 months. Additionally, clinical outcome parameters were recorded. Mann-Whitney U test and analysis of covariance were utilized for statistical analysis. RESULTS: Postoperatively, a significant prostate volume reduction was detectable in both groups. However, the relative volume reduction was lower following LV (18.4 vs. 34.7 %, p < 0.001). After 6 weeks, prostate volumes continued to decrease in both groups, yet differences between the groups were less pronounced. Nonetheless, the relative volume reduction remained significantly lower following LV (12 months 43.3 vs. 50.3 %, p < 0.001). All clinical outcome parameters improved significantly in both groups. However, the maximum flow rate (Q max) and prostate-specific antigen (PSA) reduction were significantly lower following LV. Subgroup analyses revealed significant differences only if the initial prostate volume was >40 ml. Re-operations were necessary in three patients following LV. CONCLUSIONS: The modest but significantly lower volume reduction following LV was associated with a lower PSA reduction, a lower Q max and more re-operations. Given the lack of long-term results after LV, our results are helpful for preoperative patient counseling. Patients with large prostates and no clear indication for the laser might not benefit from the procedure.


Subject(s)
Imaging, Three-Dimensional , Prostate/diagnostic imaging , Prostate/pathology , Prostatectomy/methods , Prostatic Hyperplasia/surgery , Aged , Aged, 80 and over , Humans , Laser Therapy , Male , Middle Aged , Organ Size , Prospective Studies , Prostate/surgery , Transurethral Resection of Prostate , Ultrasonography
8.
J Endourol ; 27(10): 1261-6, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23806049

ABSTRACT

INTRODUCTION AND OBJECTIVES: Bipolar plasma vaporization (BPV) has been introduced as an alternative to transurethral resection of the prostate (TURP). Promising short-term results, but inferior mid-term results compared to TURP have been reported following first-generation bipolar electrovaporization. Outcome data following second-generation BPV are still scarce. The aim of this investigation was to evaluate the intra- and postoperative outcomes of contemporary BPV in a center with long-standing expertise on laser vaporization of the prostate. METHODS: A consecutive series of 83 patients undergoing BPV in a tertiary referral center was prospectively evaluated. The investigated outcome parameters included the maximum flow rate (Qmax), postvoid residual volume, International Prostate Symptom Score (IPSS)/quality of life (Qol), and prostate-specific antigen (PSA) tests. Follow-up investigations took place after 6 weeks, 6 months, and 12 months. The Wilcoxon signed-rank test was used to compare pre- and post-treatment parameters. RESULTS: The median (range) preoperative prostate volume was 41 mL (17-111 mL). The preoperative IPSS, Qol, Qmax, and residual volume were 16 (2-35), 4 (0-6), 10.1 mL/s (3-29.3 mL/s), and 87 mL (0-1000 mL), respectively. One third of the patients were undergoing platelet aggregation inhibition (PAI). No intraoperative complications occurred. Postoperatively, 13 patients (15.7%) had to be recatheterized. Three patients (3.6%) had clot retention and 28 patients (34%) reported any grade of dysuria. After 6 weeks, all outcome parameters improved significantly and remained improved over the 12-month observation period [IPSS: 3 (0-2); Qol: 1 (0-4); Qmax: 17.2 mL/s (3.2-56 mL/s); residual volume 11 mL (0-190 mL)]. The PSA reduction was 60% at study conclusion. Three patients (3.6%) developed a urethral stricture and four patients (4.8%) bladder neck sclerosis. Re-resections were not necessary. CONCLUSIONS: Contemporary BPV is a safe and efficacious treatment option even for patients undergoing PAI. Early urinary retention and temporary dysuria seem to be specific side effects of the treatment. Bleeding complications are rare. Long-term follow-up is needed to confirm these promising short-term results.


Subject(s)
Laser Therapy/adverse effects , Laser Therapy/methods , Prostatectomy/adverse effects , Prostatectomy/methods , Prostatic Diseases/surgery , Aged , Aged, 80 and over , Humans , Male , Middle Aged , Postoperative Complications , Prospective Studies , Prostatic Diseases/psychology , Quality of Life , Treatment Outcome
9.
Eur Urol ; 55(3): 679-85, 2009 Mar.
Article in English | MEDLINE | ID: mdl-18387731

ABSTRACT

BACKGROUND: The potassium-titanyl-phosphate (KTP) laser technique for photo-selective vaporisation of the prostate (PVP) has been regularly improved over the last decade. Nonetheless, decreasing efficiency of tissue vaporisation during the course of the operation and macroscopic alterations of the laser fibre's tip are regularly observed and seem to affect the outcome of this procedure. OBJECTIVE: To investigate the course of power output and to determine the type and extent of fibre deterioration during PVP. DESIGN, SETTING, AND PARTICIPANTS: Forty laser fibres were investigated during PVP in 35 consecutive patients with prostatic bladder outflow obstruction between January 2007 and August 2007 in a university hospital. INTERVENTION: All patients underwent PVP performed by three different surgeons using the 80-W KTP laser. MEASUREMENTS: Power output was measured at the beginning and regularly throughout PVP and throughout in vitro vaporisation without fibre-tissue contact. Microscopic documentation of the fibre tip was performed after the procedure. RESULTS AND LIMITATIONS: Carbonisation and melting of the fibre tip was regularly visible and appeared to be more pronounced as more energy was applied. Additionally, 90% of the fibres showed a significant decrease of power output during PVP, resulting in an end-of-lifespan (ie, 275-kilojoule) median power output of 20% of the initial value. Final median power output after in vitro vaporisation was 83% of the starting value. The extent of the structural and functional changes might only be valid for the operative technique performed in this investigation. CONCLUSIONS: Fibre deterioration caused significant reduction of power output during PVP. This finding is an explanation for the often observed decreasing efficiency of tissue ablation and may also be responsible for some of the typical drawbacks and complications of PVP. Hence, improvements in fibre quality are necessary to advance the efficiency of this technique.


Subject(s)
Electricity , Lasers, Solid-State , Transurethral Resection of Prostate/instrumentation , Aged , Aged, 80 and over , Equipment Failure , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL