Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Therapeutic Methods and Therapies TCIM
Database
Language
Affiliation country
Publication year range
1.
Respir Care ; 64(3): 307-312, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30538161

ABSTRACT

BACKGROUND: In a previous study of subjects suspected of having ventilator-associated pneumonia, a rapid susceptibility testing approach by using ETEST (BioMérieux) strips directly applied to bronchoalveolar lavage samples provided valuable information at hour 24. The primary objective of this study was to assess a new direct specimen testing by using an even more-rapid E-test approach (at hour 10), which could promote an early de-escalation of the antimicrobial therapy. METHODS: Twenty-eight subjects with ventilator-associated pneumonia admitted to a medical ICU were prospectively included. In parallel with standard routine methods, E-test strips were directly applied onto agar plates seeded with bronchoalveolar lavage samples and were analyzed after 10 h of incubation. E-test results were used to identify potential drug choices by simulating clinical decision making if the microscopy results had been available at the point of care. These choices were analyzed for concordance with the narrowest adequate antimicrobial therapy according to the Minimum Inhibitory Concentrations (MICs) provided by the reference method (ie, the laboratory routine diagnostic). RESULTS: At hour 10, direct specimen testing was readable in 18 of 28 bronchoalveolar lavage samples (64%). Total agreement between the 10-h direct specimen testing approach and the laboratory routine diagnostic approach was 90%, with a sensitivity of 83% and a specificity of 95%, with 8% major errors and 3% very major errors. The concordance between the 2 tests was very good (kappa = 0.79). If the 10-h E-test results were taken into account, then an early de-escalation strategy would have been possible in 10 of 18 cases (55%) at hour 10. CONCLUSIONS: This rapid susceptibility testing approach provided early (10 h) and valuable information that could lead to an early adjustment of empirical antimicrobial treatment in a ventilator-associated pneumonia setting. (ClinicalTrials.gov registration NCT01266863.).


Subject(s)
Anti-Bacterial Agents/pharmacology , Bronchoalveolar Lavage Fluid/microbiology , Pneumonia, Ventilator-Associated/drug therapy , Pneumonia, Ventilator-Associated/microbiology , Aged , Anti-Bacterial Agents/therapeutic use , Cohort Studies , Early Diagnosis , Female , Humans , Intensive Care Units , Male , Microbial Sensitivity Tests/methods , Middle Aged , Pneumonia, Ventilator-Associated/diagnosis , Prospective Studies , Sensitivity and Specificity , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL