1.
Int J Cardiol ; 336: 67-72, 2021 08 01.
Article in English | MEDLINE | ID: mdl-33992702

ABSTRACT

BACKGROUND: A single­lead implantable cardioverter-defibrillator (ICD) with a floating atrial dipole has been developed to enhance the diagnostic capability of atrial arrhythmias and to facilitate adjudication of arrhythmic events without the additional effort required for atrial lead insertion. However, there have been concerns about the long-term reliability of atrial sensing. METHODS: We enrolled patients with the single-chamber ICD with atrial-sensing electrodes from 4 tertiary university hospitals in Korea. Minimal, maximal, and mean P wave amplitudes were collected at 3-6 months, 6-12 months, and 12-24 months after implantation. The difference between the minimal and maximal sensing amplitudes was calculated as an indicator of the variability of atrial sensing, while the atrial sensing stability was assessed using the mean amplitude. RESULTS: A total of 86 patients were included for analysis. The variability of atrial sensing amplitudes significantly decreased at 12-24 months compared to 3-6 months (p = 0.01), while mean atrial amplitudes were stable throughout the mean follow-up duration of 17.4 months. Nine patients (10.5%) experienced inappropriate ICD therapy mostly due to misclassification of supraventricular tachycardia. CONCLUSIONS: Under the hypothesis that sensing stability can be guaranteed as the variability decreases with time, we suggest that the concern about long-term sensing stability of a floating dipole can be abated with an ICD that has been implanted for over 2 years.


Subject(s)
Defibrillators, Implantable , Electrophysiologic Techniques, Cardiac , Heart Atria/diagnostic imaging , Humans , Reproducibility of Results , Republic of Korea
2.
J Cardiovasc Electrophysiol ; 24(11): 1240-5, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23889813

ABSTRACT

INTRODUCTION: An early repolarization (ER) pattern on electrocardiogram (ECG) sometimes has the risk of polymorphic ventricular tachycardia (PVT) or ventricular fibrillation (VF). An abnormal ER pattern can develop in various experimental or clinical situations. We experienced 4 cases of abnormal ER pattern with or without PVT during the radiofrequency (RF) ablation of the left accessory pathway. METHODS AND RESULTS: An electrophysiologic study and RF ablation were performed in 4 patients. Four patients had atrioventricular reentrant tachycardia. During RF ablation of the left accessory pathway, severe chest pain developed and was followed by abnormal J-point elevation. During the ongoing chest pain and J-point elevation, coronary angiograms showed normal findings. The chest pain and J-point elevation were followed by PVT or VF that was unresponsive to defibrillation. The PVT was spontaneously terminated and repeated. After 0.5 mg atropin was given, chest pain and ECG change disappeared. CONCLUSION: The mechanisms of ER syndrome during RF ablation might be increased vagal tone due to chest pain or direct vagal stimulation.


Subject(s)
Accessory Atrioventricular Bundle/surgery , Catheter Ablation/adverse effects , Tachycardia, Atrioventricular Nodal Reentry/surgery , Tachycardia, Ventricular/etiology , Accessory Atrioventricular Bundle/diagnosis , Accessory Atrioventricular Bundle/physiopathology , Adult , Aged , Anti-Arrhythmia Agents/therapeutic use , Atropine/therapeutic use , Coronary Angiography , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/drug therapy , Tachycardia, Ventricular/physiopathology , Treatment Outcome , Vagus Nerve/drug effects , Vagus Nerve/physiopathology , Young Adult