Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Surg Endosc ; 34(5): 2243-2247, 2020 05.
Article in English | MEDLINE | ID: mdl-31346751

ABSTRACT

INTRODUCTION: Chronic anemia is a common, coinciding or presenting diagnosis in patients with paraesophageal hernia (PEH). Presence of endoscopically identified ulcerations frequently prompts surgical consultation in the otherwise asymptomatic patient with anemia. Rates of anemia resolution following paraesophageal hernia repair (PEHR) often exceed the prevalence of such lesions in the study population. A defined algorithm remains elusive. This study aims to characterize resolution of anemia after PEHR with respect to endoscopic diagnosis. MATERIALS AND METHODS: Retrospective review of a prospectively maintained database of patients with PEH and anemia undergoing PEHR from 2007 to 2018 was performed. Anemia was determined by preoperative labs: Hgb < 12 mg/dl in females, Hgb < 13 mg/dl in males, or patients with ongoing iron supplementation. Improvement of post-operative anemia was assessed by post-operative hemoglobin values and continued necessity of iron supplementation. RESULTS: Among 56 identified patients, 45 were female (80.4%). Forty patients (71.4%) were anemic by hemoglobin value, 16 patients (28.6%) required iron supplementation. Mean age was 65.1 years, with mean BMI of 27.7 kg/m2. One case was a Type IV PEH and the rest Type III. 32 (64.0%) had potential source of anemia: 16 (32.0%) Cameron lesions, 6 (12.0%) gastric ulcers, 12 (24.0%) gastritis. 10 (20.0%) had esophagitis and 4 (8%) Barrett's esophagus. 18 (36%) PEH patients had normal preoperative EGD. Median follow-up was 160 days. Anemia resolution occurred in 46.4% of patients. Of the 16 patients with pre-procedure Cameron lesions, 10 (63%) had resolution of anemia. Patients with esophagitis did not achieve resolution. 72.2% (13/18) of patients with no lesions on EGD had anemia resolution (p = 0.03). CONCLUSION: Patients with PEH and identifiable ulcerations showed 50% resolution of anemia after hernia repair. Patients without identifiable lesions on endoscopy demonstrated statistically significant resolution of anemia in 72.2% of cases. Anemia associated with PEH adds an indication for surgical repair with curative intent.


Subject(s)
Anemia/etiology , Anemia/surgery , Hernia, Hiatal/surgery , Herniorrhaphy/methods , Adult , Aged , Aged, 80 and over , Anemia/epidemiology , Endoscopy, Digestive System , Female , Hemoglobins/analysis , Hernia, Hiatal/complications , Hernia, Hiatal/diagnostic imaging , Hernia, Hiatal/epidemiology , Herniorrhaphy/adverse effects , Herniorrhaphy/mortality , Humans , Laparoscopy/adverse effects , Laparoscopy/methods , Male , Middle Aged , Mortality , Postoperative Complications/etiology , Prevalence , Retrospective Studies , Robotic Surgical Procedures/adverse effects , Robotic Surgical Procedures/methods , Treatment Outcome
2.
Ann Surg ; 265(1): 205-211, 2017 01.
Article in English | MEDLINE | ID: mdl-28009747

ABSTRACT

OBJECTIVE: The aim of the study was to evaluate biosynthetic absorbable mesh in single-staged contaminated (Centers for Disease Control class II and III) ventral hernia (CVH) repair over 24 months. BACKGROUND: CVH has an increased risk of postoperative infection. CVH repair with synthetic or biologic meshes has reported chronic biomaterial infections and high hernia recurrence rates. METHODS: Patients with a contaminated or clean-contaminated operative field and a hernia defect at least 9 cm had a biosynthetic mesh (open, sublay, retrorectus, or intraperitoneal) repair with fascial closure (n = 104). Endpoints included overall Kaplan-Meier estimates for hernia recurrence and postoperative wound infection rates at 24 months, and the EQ-5D and Short Form 12 Health Survey (SF-12). Analyses were conducted on the intent-to-treat population, and health outcome measures evaluated using paired t tests. RESULTS: Patients had a mean age of 58 years, body mass index of 28 kg/m, 77% had contaminated wounds, and 84% completed 24-months follow-up. Concomitant procedures included fistula takedown (n = 24) or removal of infected previously placed mesh (n = 29). Hernia recurrence rate was 17% (n = 16). At the time of CVH repair, intraperitoneal placement of the biosynthetic mesh significantly increased the risk of recurrences (P ≤ 0.04). Surgical site infections (19/104) led to higher risk of recurrence (P < 0.01). Mean 24-month EQ-5D (index and visual analogue) and SF-12 physical component and mental scores improved from baseline (P < 0.05). CONCLUSIONS: In this prospective longitudinal study, biosynthetic absorbable mesh showed efficacy in terms of long-term recurrence and quality of life for CVH repair patients and offers an alternative to biologic and permanent synthetic meshes in these complex situations.


Subject(s)
Absorbable Implants , Hernia, Ventral/surgery , Herniorrhaphy/instrumentation , Quality of Life , Surgical Mesh , Surgical Wound Infection/etiology , Adult , Aged , Aged, 80 and over , Female , Health Status Indicators , Herniorrhaphy/methods , Humans , Kaplan-Meier Estimate , Longitudinal Studies , Male , Middle Aged , Prospective Studies , Recurrence , Surgical Wound Infection/epidemiology , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL