Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Cancers (Basel) ; 5(1): 12-4, 2012 Dec 27.
Article in English | MEDLINE | ID: mdl-24356571

ABSTRACT

We appreciate the thoughtful comments from Dr. Jack Fowler on our recent manuscript of an estimation of radiobiological parameters for head and neck cancer (HNC) and the clinical implications [1]. [...].

2.
Med Phys ; 36(11): 5261-91, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19994536

ABSTRACT

The concept of in-air output ratio (Sc) was introduced to characterize how the incident photon fluence per monitor unit (or unit time for a Co-60 unit) varies with collimator settings. However, there has been much confusion regarding the measurement technique to be used that has prevented the accurate and consistent determination of Sc. The main thrust of the report is to devise a theoretical and measurement formalism that ensures interinstitutional consistency of Sc. The in-air output ratio, Sc, is defined as the ratio of primary collision water kerma in free-space, Kp, per monitor unit between an arbitrary collimator setting and the reference collimator setting at the same location. Miniphantoms with sufficient lateral and longitudinal thicknesses to eliminate electron contamination and maintain transient electron equilibrium are recommended for the measurement of Sc. The authors present a correction formalism to extrapolate the correct Sc from the measured values using high-Z miniphantom. Miniphantoms made of high-Z material are used to measure Sc for small fields (e.g., IMRT or stereotactic radiosurgery). This report presents a review of the components of Sc, including headscatter, source-obscuring, and monitor-backscattering effects. A review of calculation methods (Monte Carlo and empirical) used to calculate Sc for arbitrary shaped fields is presented. The authors discussed the use of Sc in photon dose calculation algorithms, in particular, monitor unit calculation. Finally, a summary of Sc data (from RPC and other institutions) is included for QA purposes.


Subject(s)
Air , Photons/therapeutic use , Radiotherapy/methods , Absorption , Algorithms , Models, Theoretical , Monte Carlo Method , Phantoms, Imaging , Quality Control , Radiotherapy/instrumentation , Radiotherapy/standards , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/instrumentation , Radiotherapy, Intensity-Modulated/methods , Radiotherapy, Intensity-Modulated/standards , Reference Standards , Scattering, Radiation , Water
3.
Int J Radiat Oncol Biol Phys ; 75(5): 1528-36, 2009 Dec 01.
Article in English | MEDLINE | ID: mdl-19931735

ABSTRACT

PURPOSE: To find the mitigators of pneumonitis induced by moderate doses of thoracic radiation (10-15 Gy). METHODS AND MATERIALS: Unanesthetized WAG/RijCmcr female rats received a single dose of X-irradiation (10, 12, or 15 Gy at 1.615 Gy/min) to the thorax. Captopril (an angiotensin-converting enzyme inhibitor) or losartan (an angiotensin receptor blocker) was administered in the drinking water after irradiation. Pulmonary structure and function were assessed after 8 weeks in randomly selected rats by evaluating the breathing rate, ex vivo vascular reactivity, and histopathologic findings. Survival analysis was undertaken on all animals, except those scheduled for death. RESULTS: Survival after a dose of 10 Gy to the thorax was not different from that of unirradiated rats for

Subject(s)
Angiotensin Receptor Antagonists , Angiotensin-Converting Enzyme Inhibitors/therapeutic use , Captopril/therapeutic use , Losartan/therapeutic use , Radiation Pneumonitis/drug therapy , Renin-Angiotensin System/drug effects , Angiotensin-Converting Enzyme Inhibitors/administration & dosage , Animals , Captopril/administration & dosage , Drug Evaluation, Preclinical/methods , Female , Losartan/administration & dosage , Lung/pathology , Lung/physiopathology , Lung/radiation effects , Pulmonary Artery/drug effects , Pulmonary Artery/physiology , Pulmonary Artery/radiation effects , Radiation Dosage , Radiation Injuries, Experimental/drug therapy , Radiation Injuries, Experimental/mortality , Radiation Injuries, Experimental/pathology , Radiation Injuries, Experimental/physiopathology , Radiation Pneumonitis/mortality , Radiation Pneumonitis/pathology , Radiation Pneumonitis/physiopathology , Rats , Renin-Angiotensin System/physiology , Respiratory Mechanics/drug effects , Respiratory Mechanics/physiology , Respiratory Mechanics/radiation effects , Time Factors , Vasoconstriction/drug effects , Vasoconstriction/physiology , Vasoconstriction/radiation effects , Vasodilation/drug effects , Vasodilation/physiology , Vasodilation/radiation effects
4.
Med Phys ; 32(7): 2279-87, 2005 Jul.
Article in English | MEDLINE | ID: mdl-16121583

ABSTRACT

In the management of early breast cancer, a partial breast irradiation technique called MammoSite (Proxima Therapeutic Inc., Alpharetta, GA) has been advocated in recent years. In MammoSite, a balloon implanted at the surgical cavity during tumor excision is filled with a radio-opaque solution, and radiation is delivered via a high dose rate brachytherapy source situated at the center of the balloon. Frequently air may be introduced during placement of the balloon and/or injection of the contrast solution into the balloon. The purpose of this work is to quantify as well as to understand dose perturbations due to the presence of a high-Z contrast medium and/or an air bubble with measurements and Monte Carlo calculations. In addition, the measured dose distribution is compared with that obtained from a commercial treatment planning system (Nucletron PLATO system). For a balloon diameter of 42 mm, the dose variation as a function of distance from the balloon surface is measured for various concentrations of a radio-opaque solution (in the range 5%-25% by volume) with a small volume parallel plate ion chamber and a micro-diode detector placed perpendicular to the balloon axis. Monte Carlo simulations are performed to provide a basic understanding of the interaction mechanism and the magnitude of dose perturbation at the interface near balloon surface. Our results show that the radio-opaque concentration produces dose perturbation up to 6%. The dose perturbation occurs mostly within the distances <1 mm from the balloon surface. The Plato system that does not include heterogeneity correction may be sufficient for dose planning at distances > or = 10 mm from the balloon surface for the iodine concentrations used in the MammoSite procedures. The dose enhancement effect near the balloon surface (<1 mm) due to the higher iodine concentration is not correctly predicted by the Plato system. The dose near the balloon surface may be increased by 0.5% per cm3 of air. Monte Carlo simulation suggests that the interface effect (enhanced dose near surface) is primarily due to Compton electrons of short range (<0.5 mm). For more accurate dosimetry in MammoSite delivery, the dose perturbation due to the presence of a radio-opaque contrast medium and air bubbles should be considered in a brachytherapy planning system.


Subject(s)
Brachytherapy/methods , Catheterization/methods , Contrast Media/adverse effects , Models, Biological , Radiation Injuries/etiology , Radiation Injuries/prevention & control , Radiometry/methods , Artifacts , Computer Simulation , Female , Humans , Models, Statistical , Monte Carlo Method , Radiotherapy Dosage , Relative Biological Effectiveness , Scattering, Radiation
5.
Med Phys ; 30(1): 27-33, 2003 Jan.
Article in English | MEDLINE | ID: mdl-12557975

ABSTRACT

Beta emitting source wires or seeds have been adopted in clinical practice of intravascular brachytherapy for coronary vessels. Due to the limitation of penetration depth, this type of source is normally not applicable to treat vessels with large diameter, e.g., peripheral vessel. In the effort to extend application of its beta source for peripheral vessels, Novoste has recently developed a new catheter-based system, the Corona 90Sr/90Y system. It is a source train of 6 cm length and is jacketed by a balloon. The existence of the balloon increases the penetration of the beta particles and maintains the source within a location away from the vessel wall. Using the EGSnrc Monte Carlo system, we have calculated the two-dimensional (2-D) dose rate distribution of the Corona system in water for a balloon diameter of 5 mm. The dose rates on the transverse axis obtained in this study are in good agreement with calibration results of the National Institute of Standards and Technology for the same system for balloon diameters of 5 and 8 mm. Features of the 2-D dose field were studied in detail. The dose parameters based on AAPM TG-60 protocol were derived. For a balloon diameter of 5 mm, the dose rate at the reference point (defined as r0 = 4.5 mm, 2 mm from the balloon surface) is found to be 0.01028 Gy min(-1) mCi(-1). A new formalism for a better characterization of this long source is presented. Calculations were also performed for other balloon diameters. The dosimetry for this source is compared with a 192Ir source, commonly used for peripheral arteries. In conclusion, we have performed a detailed dosimetric characterization for a new beta source for peripheral vessels. Our study shows that, from dosimetric point of view, the Corona system can be used for the treatment of an artery with a large diameter, e.g., peripheral vessel.


Subject(s)
Brachytherapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Strontium Radioisotopes/therapeutic use , Yttrium Radioisotopes/therapeutic use , Brachytherapy/instrumentation , Catheters, Indwelling , Humans , Iridium Radioisotopes/therapeutic use , Monte Carlo Method , Radiometry/methods , Radiopharmaceuticals/therapeutic use , Radiotherapy Dosage , Sensitivity and Specificity , Vascular Diseases/radiotherapy , Water
SELECTION OF CITATIONS
SEARCH DETAIL