Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
Am J Transplant ; 23(3): 366-376, 2023 03.
Article in English | MEDLINE | ID: mdl-36695682

ABSTRACT

Vitamin D sufficiency is associated with a reduced risk of fractures, diabetes mellitus, cardiovascular events, and cancers, which are frequent complications after renal transplantation. The VITALE (VITamin D supplementation in renAL transplant recipients) study is a multicenter double-blind randomized trial, including nondiabetic adult renal transplant recipients with serum 25-hydroxy vitamin D (25(OH) vitamin D) levels of <30 ng/mL, which is randomized 12 to 48 months after transplantation to receive high (100 000 IU) or low doses (12 000 IU) of cholecalciferol every 2 weeks for 2 months and then monthly for 22 months. The primary outcome was a composite endpoint, including diabetes mellitus, major cardiovascular events, cancer, and death. Of 536 inclusions (50.8 [13.7] years, 335 men), 269 and 267 inclusions were in the high-dose and low-dose groups, respectively. The serum 25(OH) vitamin D levels increased by 23 versus 6 ng/mL in the high-dose and low-dose groups, respectively (P < .0001). In the intent-to-treat analysis, 15% versus 16% of the patients in the high-dose and low-dose groups, respectively, experienced a first event of the composite endpoint (hazard ratio, 0.94 [0.60-1.48]; P = .78), whereas 1% and 4% of patients in the high-dose and low-dose groups, respectively, experienced an incident symptomatic fracture (odds ratio, 0.24 [0.07-0.86], P = .03). The incidence of adverse events was similar between the groups. After renal transplantation, high doses of cholecalciferol are safe but do not reduce extraskeletal complications (trial registration: ClinicalTrials.gov; identifier: NCT01431430).


Subject(s)
Cardiovascular Diseases , Kidney Transplantation , Vitamin D Deficiency , Male , Adult , Humans , Cholecalciferol/adverse effects , Kidney Transplantation/adverse effects , Vitamin D/therapeutic use , Vitamins/adverse effects , Double-Blind Method , Dietary Supplements , Cardiovascular Diseases/etiology , Vitamin D Deficiency/complications , Vitamin D Deficiency/drug therapy
2.
J Dairy Sci ; 105(2): 1638-1648, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34802728

ABSTRACT

The objective of this observational cross-sectional study was to describe the cleanliness of various equipment used for colostrum harvest and calf feeding procedures on dairy farms in Québec, Canada. The study was performed on 42 commercial dairy herds also enrolled in another study aiming to determine the transfer of passive immunity over a 14-mo period. Information on colostrum quality (using Brix value) and cleanliness (total aerobic and total coliform count) were recorded as well as various practices focused on colostrum-feeding equipment and preweaning period using a standard questionnaire. During the study period, colostrum and milk-feeding equipment cleanliness was assessed using direct surface swabbing with Hygiena Ultrasnap swabs. A total of 155 swab samples were obtained from 6 pieces of equipment. Adenosine triphosphate collected from the swabbed surface reacts with the luciferase solution present in the swab by bioluminescence, which is proportional to the quantity of ATP present and quantified as relative light units (RLU). The description of feed equipment cleanliness (defined as the maximal RLU found for a specific herd, dichotomized as <1,000 RLU vs. ≥1,000 RLU) was compared with the herds' descriptive characteristics, focusing on the first 2 components of a multiple correspondence analysis. The median (range) RLU for buckets used for colostrum harvest, bucket or bottle used for feeding, tube feeders, milking colostrum line, and internal surface of the nipples were 41 RLU (3-1,625 RLU), 78 RLU (<1-3,765 RLU), 29 RLU (<1-2,177 RLU), 83 RLU (<1-9,968 RLU), and 1,101 RLU (2-9,546 RLU), respectively. The first 2 components of multiple correspondence analysis explained 24.7% of data variances and were related to the farms' hygiene and health (13.0%) and feeding practices (11.7% of data variance). The maximal dichotomized luminometry value (<1,000 RLU or ≥1,000 RLU) was associated with hygiene and health dimension. This study gave promising results concerning the potential application of ATP luminometry for calf rearing practices assessment.


Subject(s)
Colostrum , Dairying , Adenosine Triphosphate , Animals , Farms , Female , Milk , Pregnancy
SELECTION OF CITATIONS
SEARCH DETAIL