Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Clin Imaging ; 40(3): 425-30, 2016.
Article in English | MEDLINE | ID: mdl-27133680

ABSTRACT

PURPOSE: Compare colonic distension using CT colonography (CTC) and CT with water enema (CTWE) in the same patients. METHODS AND MATERIALS: Twenty-seven patients who underwent both CTC and CTWE, considering separately supine (CTC-S) and prone (CTC-P) acquisition of CTC were included. The colon was divided into six segments, performing both a qualitative and quantitative analysis. RESULTS: Adequate distension of sigmoid colon was more frequently achieved with CTC-P and CTWE compared to CTC-S (P<.05). CTC-P and CTWE showed better distension of the left colon compared to CTC-S (P<.01 and P=.03 regarding sigmoid colon, respectively; P=.01 and P=.03 regarding descending colon, respectively). CONCLUSIONS: Computed tomography (CT) studies of the colon should be customized to fulfill the clinical query.


Subject(s)
Colon , Colonography, Computed Tomographic/methods , Enema , Prone Position , Supine Position , Water , Adult , Aged , Aged, 80 and over , Colon, Sigmoid , Female , Humans , Male , Middle Aged
2.
Radiol Med ; 120(8): 683-9, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25690708

ABSTRACT

PURPOSE: Hiatal hernia is a well-known factor impacting on most mechanisms underlying gastroesophageal reflux, related with the risk of developing complications such as erosive esophagitis, Barrett's esophagus and ultimately, esophageal adenocarcinoma. It is our firm opinion that an erroneous reporting of hiatal hernia in CT exams performed with colonic distention may trigger a consecutive diagnostic process that is not only unnecessary, inducing a unmotivated anxiety in the patient, but also expensive and time-consuming for both the patient and the healthcare system. The purposes of our study were to determine whether colonic distention at CT with water enema and CT colonography can induce small sliding hiatal hernias and to detect whether hiatal hernias size modifications could be considered significant for both water and gas distention techniques. METHODS: We retrospectively evaluated 400 consecutive patients, 200 undergoing CT-WE and 200 undergoing CTC, including 59 subjects who also underwent a routine abdominal CT evaluation on a different time, used as internal control, while a separate group of 200 consecutive patients who underwent abdominal CT evaluation was used as external control. Two abdominal radiologists assessed the CT exams for the presence of a sliding hiatal hernia, grading the size as small, moderate, or large; the internal control groups were directly compared with the corresponding CT-WE or CTC study looking for a change in hernia size. We used the Student's t test applying a size-specific correction factor, in order to account for the effect of colonic distention: these "corrected" values were then individually compared with the external control group. RESULTS: A sliding hiatal hernia was present in 51 % (102/200) of the CT-WE patients and in 48.5 % (97/200) of the CTC patients. Internal control CT of the 31 patients with a hernia at CT-WE showed resolution of the hernia in 58.1 % (18/31) of patients, including 76.5 % (13/17) and 45.5 % (5/11) of small and moderate hernias. Comparison CT of the 28 patients with a hiatal hernia at CTC showed the absence of the hernia in 57.1 % (16/28) patients, including 68.8 % (11/16) and 50 % (5/10) of small and moderate hernias. The prevalence of sliding hiatal hernias in the external control group was 22 % (44/200), significantly lower than the CT-WE and CTC cohorts' prevalence of 51 % (p < 0.0001) and 48.5 % (p < 0.0001). After applying the correction factors for the CT-WE and the CTC groups, the estimated residual prevalences (16 and 18.5 %, respectively) were much closer to that of the external control patients (p = 0.160 for CT-WE and p = 0.455 for CTC). CONCLUSIONS: We believe that incidental findings at CT-WE and CTC should be considered according to the clinical background, and that small sliding hiatal hernias should not be reported in patients with symptoms not related to reflux disease undergoing CT-WE or CTC: When encountering these findings, accurate anamnesis and review of medical history looking for GERD-related symptoms are essential, in order to address these patients to a correct diagnostic iter, taking advantage from more appropriate techniques such as endoscopy or functional techniques.


Subject(s)
Colonography, Computed Tomographic/adverse effects , Hernia, Hiatal/etiology , Tomography, X-Ray Computed/adverse effects , Adolescent , Adult , Aged , Aged, 80 and over , Contrast Media , Enema/adverse effects , Female , Hernia, Hiatal/diagnostic imaging , Humans , Incidental Findings , Iohexol/analogs & derivatives , Male , Middle Aged , Retrospective Studies , Water
3.
Eur J Radiol ; 82(9): e434-40, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23727378

ABSTRACT

OBJECTIVES: The main objective of the present work was to determine the diagnostic value of CT-enterography with water enema (CTe-WE) in the assessment of the ileocolic anastomosis in patients with Crohn's disease (CD). The prevalence of synchronous inflammatory lesions (SILs) involving gastrointestinal segments distinct from the anastomosis was also determined. Further, the association between the type of ileocolic anastomosis and the behavior (i.e. inflammatory, stricturing, penetrating) of CD recurrence was evaluated. METHODS: 51 patients were retrospectively included (26 [51%] male and 25 [49%] female; mean age: 52.88 years ± 13.35). Ileocolic anastomoses were: 18 (35.3%) stapled side-to-side, 17 (33.3%) end-to-side, and 16 (31.4%) end-to-end. CTe-WEs were reviewed in consensus by two gastrointestinal radiologists. Endoscopy and medical records were used as reference standards. RESULTS: CTe-WE yielded 95.35% sensitivity (CI 95%: 84.19-99.43%), 75.00% specificity (CI 95%: 34.91-96.81%), and 92.15% diagnostic accuracy (CI 95%: 81.31-98.02%). Anastomotic recurrence was found in 41/51 (80.4%) patients, including 30/41 (73.2%) cases of isolated anastomotic recurrence, and 11/41 (26.8%) cases of anastomotic recurrence with a SIL. A significant lower prevalence of stricturing recurrence was observed in patients with stapled side-to-side anastomoses (p=0.033). CONCLUSIONS: CTe-WE provides a good distension of both sides of ileocolic anastomoses allowing the detection of SILs.


Subject(s)
Anastomosis, Surgical/adverse effects , Crohn Disease/diagnostic imaging , Crohn Disease/etiology , Enema , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods , Water , Colon/surgery , Female , Humans , Ileum/surgery , Male , Middle Aged , Recurrence , Reoperation , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
4.
Eur J Radiol ; 82(1): e1-e10, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22999647

ABSTRACT

OBJECTIVES: The major objective was to prospectively compare the grade of bowel distension obtained with four different computed tomography (CT) techniques dedicated for the examination of the small intestine (CT enteroclysis [CTE] and enterography [CTe]), of the colon (CT with water enema [CT-WE]), or both (CTe with water enema [CTe-WE]). The secondary objective was to assess patients' tolerance toward each CT protocol. MATERIALS AND METHODS: Recruitment was designed to obtain four groups of the same number of patients (30). Each group corresponded to a specific CT technique, for a total of 120 consecutive outpatients (65 male and 55 female, mean age 51.09 ± 13.36 years). CTE was performed after injection of methylcellulose through a nasojejunal tube, while in the CTe protocol a polyethylene glycol electrolyte solution was orally administered to patients prior to the CT acquisition. In the CT-WE protocol intraluminal contrast (water) was administered only by a rectal enema, while CTe-WE technique included both a rectal water enema and oral ingestion of neutral contrast material to obtain a simultaneous distension of small and large bowel. CT studies were reviewed in consensus by two gastrointestinal radiologists who performed a quantitative and qualitative analysis of bowel distension on a per segment basis. The presence and type of adverse effects were recorded. RESULTS: CTE provided the best distension of jejunal loops (median diameter 27 mm, range 17-32 mm) when compared to all the other techniques (p<0.0001). The frequency of patients with an adequate distension of the terminal ileum was not significantly different among the four groups (p=0.0608). At both quantitative and qualitative analysis CT-WE and CTe-WE determined a greater and more consistent luminal filling of the large intestine than that provided by both CTE and CTe (p<0.0001 for all colonic segments). Adverse effects were more frequent in patients belonging to the CTE group (p<0.0028). CONCLUSIONS: CTE allows an optimal distension of jejunal loops, but it is the most uncomfortable CT protocol. When performing CT-WE, an adequate retrograde distension of the terminal ileum was provided in a particularly high percentage of patients. CTe-WE provides a simultaneous optimal distension of both small and large bowel.


Subject(s)
Algorithms , Barium Sulfate , Enema/methods , Intestines/diagnostic imaging , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Contrast Media , Female , Humans , Male , Middle Aged , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL