Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
BMC Med Imaging ; 23(1): 110, 2023 08 23.
Article in English | MEDLINE | ID: mdl-37612644

ABSTRACT

BACKGROUND: Spectral CT imaging parameters have been reported to be useful in the differentiation of pathological grades in different malignancies. This study aims to investigate the value of spectral CT in the quantitative assessment of esophageal squamous cell carcinoma (ESCC) with different degrees of differentiation. METHODS: There were 191 patients with proven ESCC who underwent enhanced spectral CT from June 2018 to March 2020 retrospectively enrolled. These patients were divided into three groups based on pathological results: well differentiated ESCC, moderately differentiated ESCC, and poorly differentiated ESCC. Virtual monoenergetic 40 keV-equivalent image (VMI40keV), iodine concentration (IC), water concentration (WC), effective atomic number (Eff-Z), and the slope of the spectral curve(λHU) of the arterial phase (AP) and venous phase (VP) were measured or calculated. The quantitative parameters of the three groups were compared by using one-way ANOVA and pairwise comparisons were performed with LSD. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic performance of these parameters in poorly differentiated groups and non-poorly differentiated groups. RESULTS: There were significant differences in VMI40keV, IC, Eff-Z, and λHU in AP and VP among the three groups (all p < 0.05) except for WC (p > 0.05). The VMI40keV, IC, Eff-Z, and λHU in the poorly differentiated group were significantly higher than those in the other groups both in AP and VP (all p < 0.05). In the ROC analysis, IC performed the best in the identification of the poorly differentiated group and non-poorly differentiated group in VP (AUC = 0.729, Sensitivity = 0.829, and Specificity = 0.569 under the threshold of 21.08 mg/ml). CONCLUSIONS: Quantitative parameters of spectral CT could offer supplemental information for the preoperative differential diagnosis of ESCC with different degrees of differentiation.


Subject(s)
Esophageal Neoplasms , Esophageal Squamous Cell Carcinoma , Iodine , Humans , Esophageal Squamous Cell Carcinoma/diagnostic imaging , Esophageal Neoplasms/diagnostic imaging , Esophageal Neoplasms/surgery , Retrospective Studies , Analysis of Variance , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL