Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J Interv Card Electrophysiol ; 43(1): 45-54, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25690336

ABSTRACT

PURPOSE: An optimal active-can lead configuration during implantable cardioverter defibrillator (ICD) placement is important to obtain an adequate defibrillation safety margin. The purpose of this multicenter study was to evaluate the rate of the first shock success at defibrillation testing according to the type of lead implant (single vs. dual coil) and shock polarity (cathodal and anodal) in a large series of consecutive patients who received transvenous ICDs. METHODS: This was a multicenter study enrolling 469 consecutive patients. Single- versus dual-coil leads and cathodal versus anodal polarity were evaluated at defibrillation testing. In all cases, the value of the energy for the first shock was set to 20 J less than the maximum energy deliverable from the device. RESULTS: A total of 469 patients underwent defibrillation testing: 158 (34 %) had dual-coil and 311 (66 %) had single-coil lead systems configuration, 254 (54 %) received anodal shock and 215 (46 %) received cathodal shock. In 35 (7.4 %) patients, the shock was unsuccessful. No significant differences in the outcome of defibrillation testing using single- versus dual-coil lead were observed but the multivariate analysis showed an increased risk of shock failure using cathodal shock polarity (OR 2.37, 95 % CI 1.12-5.03). CONCLUSIONS: Both single- and dual-coil transvenous ICD lead systems were associated with high rates of successful ICD implantation, and we found no significant differences in ventricular arrhythmias interruption between the two ICD lead systems configuration. Instead, anodal defibrillation was more likely to be successful than cathodal defibrillation.


Subject(s)
Defibrillators, Implantable , Electric Countershock/instrumentation , Electrophysiologic Techniques, Cardiac/methods , Prosthesis Implantation/methods , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/prevention & control , Aged , Electric Countershock/methods , Equipment Design , Equipment Failure Analysis , Female , Humans , Italy , Male , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
2.
Circ Arrhythm Electrophysiol ; 4(6): 844-50, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21946316

ABSTRACT

BACKGROUND: The role of pacing sites and atrial electrophysiology on the progression of atrial fibrillation (AF) to the permanent form in patients with sinus node dysfunction (SND) has never been investigated. The aim of the study was to investigate the relationship between atrial electrophysiology and the efficacy of atrial pacing at the low interatrial septum (IAS) or at the right atrial appendage (RAA) to prevent persistent/permanent AF in patients with SND. METHODS AND RESULTS: The Electrophysiology-Guided Pacing Site Selection (EPASS) Study was a prospective, controlled, randomized study. Atrial refractoriness, basal and incremental conduction times from the RAA to the coronary sinus ostium were measured before implantation, and the difference (ΔCTos) was calculated. Patients with ΔCTos ≥ 50 ms (study group) and those with ΔCTos <50 ms (control group) were randomly assigned to RAA or IAS with algorithms for continuous atrial stimulation "on." The primary end point was time to development of permanent or persistent AF within a 2-year follow-up in the study group, IAS versus RAA. Data were analyzed by intention to treat. One hundred two patients (77 ± 7 years, 44 mol/L) were enrolled, 69 (68%) in the study group and 33 (32%) in the control group. Of these, 97 ended the study, respectively, randomly assigned: 29 IAS versus 36 RAA and 18 IAS versus 14 RAA. After a mean follow-up of 15 ± 7 (median, 17) months, 11 (16.6%) patients in the study group met the primary end point: 2 IAS versus 9 RAA (log rank=3.93, P=0.047). CONCLUSIONS: In patients with SND and intra-atrial conduction delay, low IAS pacing was superior to RAA pacing in preventing progression to persistent or permanent AF. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00239226.


Subject(s)
Atrial Appendage/physiopathology , Atrial Fibrillation/prevention & control , Atrial Septum/physiopathology , Cardiac Pacing, Artificial/methods , Electrophysiologic Techniques, Cardiac , Sick Sinus Syndrome/therapy , Aged , Aged, 80 and over , Atrial Fibrillation/diagnosis , Atrial Fibrillation/etiology , Atrial Fibrillation/physiopathology , Disease Progression , Female , Humans , Italy , Kaplan-Meier Estimate , Male , Patient Selection , Predictive Value of Tests , Prospective Studies , Refractory Period, Electrophysiological , Sick Sinus Syndrome/complications , Sick Sinus Syndrome/diagnosis , Sick Sinus Syndrome/physiopathology , Time Factors , Treatment Outcome
3.
Europace ; 9(7): 449-57, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17478460

ABSTRACT

AIMS: This multicentre prospective study evaluated the ability of electroanatomic mapping (EAM) using a specific parameter setting to identify clearly the mid-diastolically activated isthmus (MDAI) and guide ablation of macro-re-entrant atrial tachycardia (MAT). METHODS AND RESULTS: Consecutive patients with MAT, different from typical isthmus-dependent atrial flutter, were enrolled. EAM was performed using a specific setting of the window of interest, calculated to identify the MDAI and guide ablation of this area. Sixty-five patients exhibiting 81 MATs (mean cycle length 308 +/- 68 ms) were considered. Thirty-two (49.2%) had previous heart surgery. In 79 of 81 morphologies (97.5%), EAM reconstructed 95.9 +/- 4.3% of the tachycardia circuit and identified the MDAI; 23 of the 79 morphologies (29.1%) were double-loop re-entry. Mapping of two morphologies was incomplete due to MAT termination after catheter bumping. In 73 of 79 mapped morphologies (92.4%), abolition of the MAT was obtained by 13.2 +/- 12.4 applications. During the 14 +/- 4 month follow-up, MAT recurred in 4 of the successfully treated patients (6.8%). CONCLUSION: EAM using a specific parameter setting proved highly effective at identifying the MDAI in MAT, even in patients with previous surgery and multiple re-entrant loops. Ablation of the MDAI yielded acute arrhythmia suppression with low rate of recurrence during follow-up.


Subject(s)
Atrial Flutter/surgery , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Tachycardia, Atrioventricular Nodal Reentry/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Analysis of Variance , Atrial Flutter/physiopathology , Child , Electrocardiography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Statistics, Nonparametric , Tachycardia, Atrioventricular Nodal Reentry/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL