Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Europace ; 20(suppl_2): ii48-ii55, 2018 05 01.
Article in English | MEDLINE | ID: mdl-29722860

ABSTRACT

Aims: Oesophagogastroduodenoscopy (OGD) after catheter ablation (CA) of atrial fibrillation (AF) revealed a high rate of procedure related oesophageal lesions. We hypothesized that magnetically guided CA with careful radiofrequency energy titration at the posterior left atrial (LA) wall limits the incidence of oesophageal tissue damage. Methods and results: As a part of the prospective "Remote MAGNetic catheter Ablation for Atrial Fibrillation" (MAGNA-AF) registry, 251 out of 266 consecutive patients underwent OGD after magnetically guided single-CA for AF. All detected pathologies were analysed. Simultaneous pacing and ablation from the tip of the magnetically guided catheter was found to be a safe and feasible method for energy titration. Post-interventional OGD documented midoesophageal tissue damage in four (1.6%) patients. Although a thermal origin of these injuries must be discussed, none of them was located at the anterior oesophageal wall. Risk factors for midoesophageal lesions were female gender and concomitant acetylsalicylic acid (ASA) treatment. Mechanical lesions in 16 patients were attributed to periprocedural transoesophageal echocardiography (TOE). There was no atrio-oesophageal fistula (AOF). Five hundred and one incidental pathologies were found endoscopically, most frequent axial oesophageal herniation (71%), oesophagitis (22%), and gastritis (57%). Conclusion: Magnetically guided CA for AF with careful energy titration at the posterior LA wall and no oesophageal temperature monitoring is not associated with an increased incidence of oesophageal thermal injury. The routine use of periprocedural TOE may cause a low rate of mechanical oesophageal lesions but reliably prevents major complications like transient ischaemic attack, stroke, or cardiac tamponade. An observed high prevalence of upper digestive system inflammation (63%) may further support the recommendation for a routine post-interventional treatment with a proton-pump-inhibitor.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Catheterization/adverse effects , Catheter Ablation/adverse effects , Esophagus/injuries , Magnetics , Remote Sensing Technology/adverse effects , Surgery, Computer-Assisted/adverse effects , Wounds and Injuries/epidemiology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Cardiac Catheterization/methods , Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac , Endoscopy, Gastrointestinal , Female , Germany/epidemiology , Humans , Incidence , Magnetics/methods , Male , Prevalence , Recurrence , Registries , Remote Sensing Technology/methods , Risk Factors , Surgery, Computer-Assisted/methods , Treatment Outcome , Wounds and Injuries/diagnosis
2.
J Cardiovasc Electrophysiol ; 28(1): 85-93, 2017 01.
Article in English | MEDLINE | ID: mdl-27862594

ABSTRACT

INTRODUCTION: Cardiac resynchronization therapy (CRT) device implantation guided by an electroanatomic mapping system (EAMS) is an emerging technique that may reduce fluoroscopy and angiography use and provide information on coronary sinus (CS) electrical activation. We evaluated the outcome of the EAMS-guided CRT implantation technique in a multicenter registry. METHODS: During the period 2011-2014 we enrolled 125 patients (80% males, age 74 [71-77] years) who underwent CRT implantation by using the EnSite system to create geometric models of the patient's cardiac chambers, build activation mapping of the CS, and guide leads positioning. Two hundred and fifty patients undergoing traditional CRT implantation served as controls. Success and complication rates, fluoroscopy and total procedure times in the overall study population and according to center experience were collected. Centers that performed ≥10 were defined as highly experienced. RESULTS: Left ventricular lead implantation was successful in 122 (98%) cases and 242 (97%) controls (P = 0.76). Median fluoroscopy time was 4.1 (0.3-10.4) minutes in cases versus 16 (11-26) minutes in controls (P < 0.001). Coronary sinus angiography was performed in 33 (26%) cases and 208 (83%) controls (P < 0.001). Complications occurred in 5 (4%) cases and 17 (7%) controls (P = 0.28). Median fluoroscopy time (median 11 minutes vs. 3 minutes, P < 0.001) and CS angiography rate (55% vs. 21%, P < 0.001) were significantly higher in low experienced centers, while success rate and complications rate were similar. CONCLUSIONS: EAMS-guided CRT implantation proved safe and effective in both high- and low-experienced centers and allowed to reduce fluoroscopy use by ≈75% and angiography rate by ≈70%.


Subject(s)
Arrhythmias, Cardiac/therapy , Cardiac Resynchronization Therapy Devices , Cardiac Resynchronization Therapy , Electrophysiologic Techniques, Cardiac , Heart Failure/therapy , Imaging, Three-Dimensional , Therapy, Computer-Assisted/instrumentation , Action Potentials , Aged , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Case-Control Studies , Coronary Angiography , Feasibility Studies , Female , Fluoroscopy , Heart Failure/diagnosis , Heart Failure/physiopathology , Heart Rate , Humans , Image Interpretation, Computer-Assisted , Italy , Male , Patient-Specific Modeling , Predictive Value of Tests , Radiography, Interventional , Registries , Signal Processing, Computer-Assisted , Time Factors , Treatment Outcome , Ventricular Function, Left
SELECTION OF CITATIONS