Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Zhongguo Zhong Yao Za Zhi ; 38(16): 2661-4, 2013 Aug.
Article in Chinese | MEDLINE | ID: mdl-24228583

ABSTRACT

To explore anti-tumor active components of Chimonanthus salicifolius, the phytochemistry of the chloroform fraction from leaves extract was investigated by repeated silica gel column chromatography. Twelve compounds were isolated and their structures were identified by physicochemical properties and spectroscopic data analysis as 9-epi-blumenol C(1), blumenol C(2), (+)-dehydrovomifoliol (3), (+)-vomifoliol (4), robinlin (5), (-)-loliolide (6), isofraxidin (7), scopoletin (8), 6,7-dimethoxycoumarin (9), 6, 7, 8-trimethoxycoumarin (10), beta-sitostenone (11), and beta-stigmasterol(12). Compounds 1-6 belonging to nor-sesquiterpenoids were isolated from the family Calycanthaceae for the first time. Compound 1 was a new natural product. Compounds 7, 11 and 12 were obtained from this plant for the first time.


Subject(s)
Antineoplastic Agents/analysis , Calycanthaceae/chemistry , Chloroform/chemistry , Drugs, Chinese Herbal/analysis , Plant Leaves/chemistry , Antineoplastic Agents/isolation & purification , Drugs, Chinese Herbal/isolation & purification
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 24(12): 1666-8, 2004 Dec.
Article in Chinese | MEDLINE | ID: mdl-15828356

ABSTRACT

An ICP-AES method for the determination of silicon and phosphorus in ferromanganese was studied. Digesting samples by microwave and all kinds of parameters of the analytical method were optimized, which included selecting the acid and controlling the temperature and pressure of dissolving the sample, confirming analytical spectrum, considering the effect of sample matrix, analytical pH and disturbing elements on the determination results. By optimizing and choosing all kinds of condition parameters, the simultaneous determination of silicon and phosphorus was realized and satisfactory results were obtained. The linear correlation coefficients of Si and P were 0.9998 and 0.9996, respectively. The detection limit for silicon was 0.0060% with recovery of 97.0%-101%. The detection limit for phosphorus was 0.030%. This method is accurate and quick with less reagent dosage and broa linear range. The way of this determination is fit for the determination of silicon and phosphorus with low, middle and high carbon contents.


Subject(s)
Iron/chemistry , Manganese/chemistry , Phosphorus/analysis , Silicon/analysis , Spectrophotometry, Atomic/methods , Limit of Detection , Reference Standards
SELECTION OF CITATIONS
SEARCH DETAIL