Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Publication year range
1.
Article in Chinese | WPRIM | ID: wpr-985515

ABSTRACT

Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.


Subject(s)
Pregnancy , Child , Humans , Female , Glycated Hemoglobin , Cohort Studies , Diabetes Mellitus/diagnosis , Sensitivity and Specificity , ROC Curve
2.
Chinese Medical Journal ; (24): 2566-2574, 2018.
Article in English | WPRIM | ID: wpr-690846

ABSTRACT

<p><b>Background</b>The effect of maternal weights on the risk of iron deficiency anemia (IDA) during pregnancy remains unclear. The study aimed to investigate the association between maternal weight indicators and IDA during pregnancy.</p><p><b>Methods</b>We conducted a cohort study to examine the association between maternal weight indicators, including prepregnancy body mass index and the rate of gestational weight gain (GWG), and the risk of IDA among Chinese pregnant women. Data about new-onset IDA at different trimesters from a national cross-sectional survey were collected; information regarding baseline variables and rate of GWG from women participating in the survey were retrospectively collected. Tested IDA and reported IDA were documented. Multilevel logistic regression to examine the association between maternal weight indicators and the risk of IDA after adjusting for potential confounders was conducted.</p><p><b>Results</b>This study enrolled 11,782 pregnant women from 24 hospitals from September 19, 2016, to November 20, 2016. Among those, 1515 (12.9%) IDA events were diagnosed through test (test IDA); 3915 (33.3%) were identified through test and patient reporting (composite IDA). After adjusting for confounders and cluster effect of hospitals, underweight pregnant women, compared with normal women, were associated with higher risk of test IDA (adjusted odds ratio [aOR]: 1.35, 95% confidence interval [CI]: 1.17-1.57 and composite IDA (aOR: 1.35, 95% CI: 1.21-1.51); on the contrary, overweight and obese women had lower risk of test IDA (aOR: 0.68, 95% CI: 0.54-0.86 overweight; aOR: 0.30, 95% CI: 0.13-0.69 obese) and composite IDA (aOR: 0.77, 95% CI: 0.67-0.90 overweight; aOR: 0.34, 95% CI: 0.21-0.55 obese). The higher rate of GWG was associated with higher risk of IDA (test aOR: 1.86 95% CI: 1.26-2.76; composite aOR: 1.54, 95% CI: 1.16-2.03).</p><p><b>Conclusions</b>Pregnant women who are underweight before pregnancy and who have faster GWG are more likely to develop IDA. Enforced weight control during pregnancy and use of iron supplements, particularly among underweight women, may be warranted.</p>

SELECTION OF CITATIONS
SEARCH DETAIL