Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Orthop Surg ; 15(4): 1179-1186, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36750671

ABSTRACT

BACKGROUND: Total dislocation of the talus from all its surrounding joints (talonavicular, tibiotalar, subtalar) is one kind of serious injury of the lower extremity with rare occurrence. It is usually accompanied by fractures of the talus and its periphery, as well as severe soft tissue injury, which is difficult to reset. Complications such as skin necrosis and infection are prone to occur in the early stage, and talus necrosis are prone to occur in the late stage, all of which aggravate disease severity and increase difficulties for its treatment. CASE PRESENTATION: Herein, we reported a case of right talus total dislocation accompanied by medial malleolus fracture and posterior tubercle fracture caused by traffic accident. One hour after injury, the doctor tried to perform manual reduction but failed. Then, we successfully performed manual reduction and plaster external fixation on this patient under anesthesia 6 h after injury, followed by the oral administration of Chinese medicine for 3 months. Twenty months of follow-up investigations revealed that no skin necrosis, talus dislocation, talus necrosis, or other complications occurred; no obvious joint degeneration was observed and the fractures of medial malleolus and talus healed well. MRI of ankle joint indicated the disappearance of ankle effusion caused by injury, and the bone marrow edema had also subsided at talus, medial malleolus, and lateral malleolus and calcaneus. Patient presented with no ligament relaxation, ankle instability, pain, swelling, or functional limitation of the injured limb. AOFAS score reached 100. Daily functions and recreation activities were recovered back to the normal level. CONCLUSION: For patients with closed total dislocation of the talus, fine therapeutic effects can be achieved by early closed manual reduction and plaster external fixation under anesthesia, in combination with oral Chinese herbal medicine afterwards. It is worthy of reference for clinicians.


Subject(s)
Ankle Fractures , Joint Dislocations , Talus , Humans , Talus/surgery , Fracture Fixation, Internal , External Fixators , Fracture Fixation , Ankle Fractures/diagnostic imaging , Ankle Fractures/surgery , Ankle Fractures/complications , Joint Dislocations/surgery , Lower Extremity , Treatment Outcome
2.
Article in Chinese | WPRIM | ID: wpr-910033

ABSTRACT

Objective:To compare the curative efficacy in the treatment of humeral surgical neck fractures between open reduction and locking plating versus closed reduction and interlocking intramedullary nailing.Methods:From July 2018 to July 2020, 60 patients with humeral surgical neck fracture were treated at Department of Orthorpaedic Trauma, Jiangmen Wuyi Hospital of Traditional Chinese Medicine. They were 24 males and 36 females, aged from 40 to 70 years and injured at the left side in 35 cases and at the right side in 25 ones. Of them, 30 underwent open reduction and locking plating (open group) and the other 30 closed reduction and interlocking intramedullary nailing (closed group). The 2 groups were compared in terms of operation time, intraoperative blood loss, surgical incision length, fracture healing time, Neer shoulder function scoring 3 months after surgery, and postoperative complications.Results:There were no statistically significant differences between the open and closed groups in preoperative general data, showing they were comparable ( P>0.05). The length of surgical incision [(5.2±1.1) cm], operation time [(34.3±12.7) min], intraoperative blood loss [(52.5±7.3) mL] and fracture healing time [(9.2±1.5) weeks] in the closed group were significantly better than those in the open group [(11.1±2.5) cm, (69.4±21.4) min, (123.5±5.2) mL and (14.2±3.4) weeks)] ( P<0.05). The excellent and good rate by Neer shoulder function scoring at 3 months after operation in the closed group (93.3%, 28/30) was significantly higher than that in the open group (66.7%, 20/30) ( P<0.05). There were no postoperative complications in either group. Conclusion:In the treatment of humeral surgical neck fractures, the curative efficacy of closed reduction and interlocking intramedullary nailing is better than that of open reduction and locking plating.

3.
J Plast Reconstr Aesthet Surg ; 70(8): 1044-1050, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28572044

ABSTRACT

PURPOSE: To date, there have been no studies identifying the cost differential for performing closed reduction internal fixation (CRIF) of hand fractures in the operating room (OR) versus an ambulatory setting. Our goal was to analyse the cost and efficiency of performing CRIF in these two settings and to investigate current practice trends in Canada. METHODS: A detailed analysis of the costs involved both directly and indirectly in the CRIF of a hand fracture was conducted. Hospital records were used to calculate efficiency. A survey was distributed to practicing plastic surgeons across Canada regarding their current practice of managing hand fractures. RESULTS: In an eight-hour surgical block we are able to perform five CRIF in the OR versus eight in an ambulatory setting. The costs of performing a CRIF in the OR under local anaesthetic, not including surgeon compensation, is $461.27 Canadian (CAD) compared to $115.59 CAD in the ambulatory setting, a 299% increase. The use of a regional block increases the cost to $665.49 CAD, a 476% increase. The main barrier to performing CRIFs in an outpatient setting is the absence of equipment necessary to perform these cases effectively, based on survey results. CONCLUSION: The use of the OR for CRIF of hand fractures is associated with a significant increase in cost and hospital resources with decreased efficiency. For appropriately selected hand fractures, CRIF in an ambulatory setting is less costly and more efficient compared to the OR and resources should be allocated to facilitate CRIF in this setting.


Subject(s)
Ambulatory Care Facilities/economics , Closed Fracture Reduction/economics , Fracture Fixation, Internal/economics , Fractures, Bone/economics , Hand Injuries/surgery , Health Care Costs , Operating Rooms/economics , Anesthesia, Local/economics , Canada , Costs and Cost Analysis , Efficiency , Finger Phalanges/injuries , Finger Phalanges/surgery , Hand Injuries/economics , Humans , Metacarpal Bones/injuries , Metacarpal Bones/surgery , Nerve Block/economics , Surgical Equipment
4.
Acta Otolaryngol ; 137(3): 331-336, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28225317

ABSTRACT

CONCLUSION: Closed reduction is effective and safe for the treatment of arytenoid dislocation, and the selection of an appropriate time window to perform closed reduction is crucial in achieving relatively stable treatment outcomes and short treatment duration. OBJECTIVE: The aim of this study was to investigate whether there is an appropriate time window to perform closed reduction for unilateral arytenoid dislocation caused by intubation. METHODS: A retrospective chart review was carried out for the cases collected from September 2014 to May 2016 at Second Affiliated Hospital of Zhejiang University, China. RESULTS: Thirty-five patients with arytenoid dislocation were identified. Endotracheal intubation was the cause for 33 of the patients and gastric tube caused arytenoid dislocation in two patients. The patients were treated by closed reduction, and no major complications resulting from surgical intervention were observed. All patients regained normal voice and vocal fold movement after the surgery, except one patient who recovered spontaneously. As one of the most significant findings in the current study, we observed the relatively stable treatment outcomes and shortened recovery duration were obtained in the patients treated during a period between the 13th day and 26th day after arytenoid dislocation.


Subject(s)
Arytenoid Cartilage/injuries , Intubation, Intratracheal/adverse effects , Laryngeal Diseases/therapy , Adult , Aged , Anesthesia, Local , Female , Humans , Laryngoscopy , Male , Middle Aged , Retrospective Studies , Young Adult
5.
Injury ; 46(6): 1150-5, 2015.
Article in English | MEDLINE | ID: mdl-25702252

ABSTRACT

INTRODUCTION: Long bone fracture is common in traumatic osteopathic patients. Good reduction is beneficial for bone healing, preventing the complications such as delayed union, nonunion, malunion, but is hard to achieve. Repeated attempts during the surgery would increase the operation time, cause new damage to the fracture site and excessive exposure to radiation. Robotic and navigation techniques can help improve the reduction accuracy, however, the high cost and complexity of operation have limited their clinical application. MATERIALS AND METHODS: We combined 3D printing with computer-assisted reduction technique to develop a customised external fixator with the function of fracture reduction. The original CT data obtained by scanning the fracture was imported to computer for reconstructing and reducing the 3D image of the fracture, based on which the external fixator (named as Q-Fixator) was designed and then fabricated by 3D printing techniques. The fracture reduction and fixation was achieved by connecting the pins inserted in the bones with the customised Q-Fixator. Experiments were conducted on three fracture models to demonstrate the reduction results. RESULTS: Good reduction results were obtained on all three fractured bone models, with an average rotation of 1.21°(± 0.24), angulation of 1.84°(± 0.28), and lateral displacement of 2.22 mm(± 0.62). CONCLUSIONS: A novel customised external fixator for long bone fracture reduction was readily developed using 3D printing technique. The customised external fixator had the advantages of easy manipulation, accurate reduction, minimally invasion and experience-independence. Future application of the customised external fixator can be extended to include the fixation function with stress adjustment and potentially optimise the fracture healing process.


Subject(s)
External Fixators , Printing, Three-Dimensional , Tibial Fractures/surgery , Fracture Healing , Humans , Imaging, Three-Dimensional , Precision Medicine , Surgery, Computer-Assisted , Tibial Fractures/pathology
6.
Article in Korean | WPRIM | ID: wpr-78133

ABSTRACT

PURPOSE: The majority of nasal fractures have been treated by closed reduction. And they were manipulated under local anesthesia or general anesthesia. Under the local anesthesia, patients can feel the pain and fear, so general anesthesia through the endotracheal intubation became popularized recently to treat the nasal fracture. But it has still the drawbacks of postanesthetic complication. Therefore, under the mask ventilation anesthesia using oral airway, we tried to manipulate the nasal fracture. METHODS: From July 2007 to November 2007, we worked with fifty patients that were manipulated the nasal fracture. Fifty patients were divided into two groups, general anesthesia with the endotracheal intubation group(n=25) and the mask ventilation using oral airway group(n=25). We checked up the anesthesia time, postanesthetic complication, postoperative aesthetic & functional problem of nose in two groups. RESULTS: In total operation time and sore throat frequency among the postoperative anesthetic complications, there was statistically significant difference between the mask ventilation group and the endotracheal intubation group(p0.05). And no patients complained of postoperative nasal complication such as septal deviation, septal perforation, nasal obstruction and hump nose in two groups. CONCLUSION: Through the mask ventilation using oral airway, we could reach satisfactory results in the anesthetic time and postanesthetic complication.


Subject(s)
Humans , Anesthesia , Anesthesia, General , Anesthesia, Local , Intubation, Intratracheal , Masks , Nasal Bone , Nasal Septal Perforation , Nausea , Nose , Pharyngitis , Postoperative Complications , Ventilation
SELECTION OF CITATIONS
SEARCH DETAIL