Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
Add more filters

Complementary Medicines
Publication year range
1.
Am J Cardiol ; 164: 103-110, 2022 02 01.
Article in English | MEDLINE | ID: mdl-34819234

ABSTRACT

The MacNew questionnaire is a disease-specific quality of life measure that has been used in patients with myocardial infarction and heart failure. We aimed to investigate the impact of transcatheter aortic valve implantation (TAVI) on health-related quality of life (HRQoL) using MacNew Questionnaire and identify predictors associated with a change in its score. This was a prospective multi-center study performed across 5 National Health Service hospitals in the United Kingdom performing TAVI between 2016 and 2018. HRQoL was assessed using MacNew Questionnaire, Euro Quality of Life-5D-5L, and Short Form 36 questionnaires collected at baseline, 3-, 6- and 12 months after the procedure. Out of 225 recruited patients, 19 did not have TAVI and 4 withdrew their consent, and hence 202 patients were included. HRQoL was assessed in 181, 161, and 147 patients at 3, 6, and 12 months, respectively. Using MacNew, there was a significant improvement in all domains of HRQoL as early as 3 months after TAVI which was sustained up to 12 months with improved discrimination of change in HRQoL compared with other scales. Poor mobility at baseline and history of myocardial infarction were independent predictors of reduced improvement in HRQoL at 3 months. HRQoL increased in all subgroups of patients including frail ones. In conclusion, the MacNew assessment tool performed well in a representative TAVI cohort and could be used as an alternative disease-specific method for assessing HRQoL change after TAVI.


Subject(s)
Aortic Valve Stenosis/surgery , Quality of Life , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/physiopathology , Comorbidity , Female , Frailty/epidemiology , Humans , Male , Mobility Limitation , Myocardial Infarction/epidemiology , Patient Reported Outcome Measures , Prospective Studies , Surveys and Questionnaires , Treatment Outcome , United Kingdom
2.
Am J Cardiol ; 156: 108-113, 2021 10 01.
Article in English | MEDLINE | ID: mdl-34344508

ABSTRACT

Aortic valve calcium (AVC) is a strong predictor of aortic stenosis (AS) severity and is typically calculated by multidetector computed tomography (MDCT). We propose a novel method using pixel density quantification software to objectively quantify AVC by two-dimensional (2D) transthoracic echocardiography (TTE) and distinguish severe from non-severe AS. A total of 90 patients (mean age 76 ± 10 years, 75% male, mean AV gradient 32 ± 11 mmHg, peak AV velocity 3.6 ± 0.6 m/s, AV area (AVA) 1.0 ± 0.3 cm2, dimensionless index (DI) 0.27 ± 0.08) with suspected severe aortic stenosis undergoing 2D echocardiography were retrospectively evaluated. Parasternal short axis aortic valve views were used to calculate a gain-independent ratio between the average pixel density of the entire aortic valve in short axis at end diastole and the average pixel density of the aortic annulus in short axis (2D-AVC ratio). The 2D-AVC ratio was compared to echocardiographic hemodynamic parameters associated with AS, MDCT AVC quantification, and expert reader interpretation of AS severity based on echocardiographic AVC interpretation. The 2D-AVC ratio exhibited strong correlations with mean AV gradient (r = 0.72, p < 0.001), peak AV velocity (r = 0.74, p < 0.001), AVC quantified by MDCT (r = 0.71, p <0.001) and excellent accuracy in distinguishing severe from non-severe AS (area under the curve = 0.93). Conversely, expert reader interpretation of AS severity based on echocardiographic AVC was not significantly related to AV mean gradient (t = 0.23, p = 0.64), AVA (t = 2.94, p = 0.11), peak velocity (t = 0.59, p = 0.46), or DI (t = 0.02, p = 0.89). In conclusion, these data suggest that the 2D-AVC ratio may be a complementary method for AS severity adjudication that is readily quantifiable at time of TTE.


Subject(s)
Aortic Valve Stenosis/diagnosis , Aortic Valve/diagnostic imaging , Calcinosis/diagnosis , Calcium/metabolism , Echocardiography/methods , Aged , Aortic Valve/metabolism , Aortic Valve Stenosis/metabolism , Aortic Valve Stenosis/physiopathology , Calcinosis/metabolism , Calcinosis/physiopathology , Female , Follow-Up Studies , Hemodynamics/physiology , Humans , Male , Retrospective Studies , Severity of Illness Index
3.
Ann Vasc Surg ; 73: 585-588, 2021 May.
Article in English | MEDLINE | ID: mdl-33556523

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has proven over the years to be a viable alternative to open surgery. A rare but severe complication is represented by the valve migration. We report a case of TAVI complication due to the loss of the prosthetic valve in the abdominal aorta treated by endovascular approach. METHODS: An 88-year-old patient with severe aortic valve stenosis, symptomatic for dyspnea was proposed for a TAVI because considered at high risk for surgery. During the TAVI procedure, the undeployed device (Edwards SAPIEN 3 - Edwards Lifesciences, Irvine, CA, USA) detached from its delivery system. Several attempts to withdraw the valve fluctuating in the aorta into its supporting system were performed without success. An emergency endovascular treatment was promptly planned to obtain the exclusion from the flow of the embolized valve. Under local anaesthesia, through the percutaneous femoral access already present, a tube aortic endograft (EndurantTM II, Medtronic, Santa Rosa, CA; ETTF2828C70EE) was successfully introduced and deployed in the infrarenal aorta without any related complications. The embolized valve was completely covered by the endgraft and thus fixed to the aortic wall. The first postoperative computer tomography angiography (CTA) confirmed the correct placement of the endograft, the exclusion of the valve from the flow and the patency of the great vessels. No perioperative or postoperative complications were recorded. The patient was discharged on the ninth postoperative day with the indication to a new attempt of TAVI, through transapical access. CONCLUSIONS: In case of intraprocedural loss of an undeplyed valve during TAVI, the valve fixing through endograft deployment in infrarenal aorta is a possible solution.


Subject(s)
Aorta, Abdominal , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Foreign-Body Migration/etiology , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Aorta, Abdominal/diagnostic imaging , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Endovascular Procedures , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/therapy , Humans , Male , Severity of Illness Index , Treatment Outcome
4.
Science ; 371(6530)2021 02 12.
Article in English | MEDLINE | ID: mdl-33303684

ABSTRACT

Mapping the gene-regulatory networks dysregulated in human disease would allow the design of network-correcting therapies that treat the core disease mechanism. However, small molecules are traditionally screened for their effects on one to several outputs at most, biasing discovery and limiting the likelihood of true disease-modifying drug candidates. Here, we developed a machine-learning approach to identify small molecules that broadly correct gene networks dysregulated in a human induced pluripotent stem cell (iPSC) disease model of a common form of heart disease involving the aortic valve (AV). Gene network correction by the most efficacious therapeutic candidate, XCT790, generalized to patient-derived primary AV cells and was sufficient to prevent and treat AV disease in vivo in a mouse model. This strategy, made feasible by human iPSC technology, network analysis, and machine learning, may represent an effective path for drug discovery.


Subject(s)
Aortic Valve Disease/drug therapy , Aortic Valve Stenosis/drug therapy , Aortic Valve/pathology , Calcinosis/drug therapy , Gene Regulatory Networks/drug effects , Machine Learning , Nitriles/pharmacology , Nitriles/therapeutic use , Thiazoles/pharmacology , Thiazoles/therapeutic use , Algorithms , Animals , Aortic Valve/drug effects , Aortic Valve/metabolism , Aortic Valve/physiopathology , Aortic Valve Disease/genetics , Aortic Valve Disease/physiopathology , Aortic Valve Stenosis/genetics , Aortic Valve Stenosis/physiopathology , Calcinosis/genetics , Calcinosis/physiopathology , Disease Models, Animal , Drug Discovery , Drug Evaluation, Preclinical , Gene Expression Regulation/drug effects , Haploinsufficiency , Humans , Induced Pluripotent Stem Cells , Mice, Inbred C57BL , RNA-Seq , Receptor, Notch1/genetics , Small Molecule Libraries
5.
J Cardiovasc Med (Hagerstown) ; 21(11): 905-911, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32858630

ABSTRACT

BACKGROUND: Vitamin D [25(OH)D] deficiency and degenerative aortic stenosis represent emerging conditions, linked to a progressive ageing of the population and increased frailty. Previous studies have associated lower levels of 25 (OH)D to the pathogenesis of atherosclerosis and vascular calcifications. However, few studies have evaluated, so far, the impact of vitamin D deficiency in patients with aortic stenosis, which was therefore the aim of present study. METHODS: Consecutive patients with severe degenerative aortic stenosis undergoing nonurgent coronary angiography were included. Aortic stenosis was defined as aortic valve area (AVA) less than 1 cm and/or mean gradient more than 40 mmHg. Indexed area and stroke volume or dobutamine stress evaluation were performed when indicated. Fasting samples were collected at admission for 25 (OH)D levels assessment. RESULTS: We included 137 patients with severe degenerative aortic stenosis (48.9% men, mean age 78.4 ±â€Š6.4 years) who were divided according to vitamin D median values (≥12.4 ng/ml). Patients with lower vitamin D had a more frequent history of coronary artery bypass graft (P = 0.02) and received more often angiotensin-converting enzyme-inhibitors (P = 0.03). Among them, 38.7% had vitamin D levels less than 10 ng/ml and only five patients were in therapy with vitamin D supplementation. We observed no significant relationship between vitamin D levels and echocardiographic parameters for the severity of aortic stenosis (AVA, peak and mean gradients, volumes, ejection fraction) except for a greater wall thickness in patients with lower vitamin D levels (r = -0.34, P = 0.03). Results did not change when excluding patients with renal failure or treated with vitamin D supplementation. CONCLUSION: Among patients with severe degenerative aortic stenosis, vitamin D deficiency is common. We found a significant association between left ventricular wall thickness and vitamin D levels, suggesting a potential role of this hormone in modulating hypertrophic remodelling in these patients. However, future larger studies are certainly needed to confirm our findings and to define their prognostic implications.


Subject(s)
Aortic Valve Stenosis/physiopathology , Hypertrophy, Left Ventricular/physiopathology , Ventricular Function, Left , Ventricular Remodeling , Vitamin D Deficiency/blood , Vitamin D/analogs & derivatives , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Biomarkers/blood , Coronary Angiography , Echocardiography, Doppler , Female , Humans , Hypertrophy, Left Ventricular/diagnostic imaging , Male , Prognosis , Retrospective Studies , Severity of Illness Index , Vitamin D/blood , Vitamin D Deficiency/diagnosis
6.
J Cardiovasc Med (Hagerstown) ; 21(10): 805-811, 2020 10.
Article in English | MEDLINE | ID: mdl-32740417

ABSTRACT

AIMS: Conscious sedation instead of general anesthesia has been increasingly adopted in many centers for transfemoral transcatheter aortic valve replacement (TAVR). Improvement of materials and operators' experience and reduction of periprocedural complications allowed procedural simplification and adoption of a minimalist approach. With this study, we sought to assess the feasibility and safety of transfemoral TAVR routinely performed under local anesthesia without on-site anesthesiology support. METHODS: The routine transfemoral TAVR protocol adopted at our center includes a minimalist approach, local anesthesia alone with fully awake patient, anesthesiologist available on call but not in the room, and direct transfer to the cardiology ward after the procedure. All consecutive patients undergoing transfemoral TAVR between January 2015 and July 2018 were included. We assessed the rates of actual local anesthesia-only procedures, conversion to conscious sedation or general anesthesia and 30-day clinical outcomes. RESULTS: Among 321 patients, 6 received general anesthesia upfront and 315 (98.1%) local anesthesia only. Mean age of the local anesthesia group was 83.2 ±â€Š6.9 years, Society of Thoracic Surgery score 5.8 ±â€Š4.8%. A balloon-expandable valve was used in 65.7%. Four patients (1.3%) shifted to conscious sedation because of pain or anxiety; 6 patients (1.9%) shifted to general anesthesia because of procedural complications. Hence, local anesthesia alone was possible in 305 patients (96.8% of the intended cohort, 95% of all transfemoral procedures). At 30 days, in the intended local anesthesia group, mortality was 1.6%, stroke 0.6%, major vascular complications 2.6%. Median hospital stay was 4 days (IQR 3-7). CONCLUSION: Transfemoral TAVR can be safely performed with local anesthesia alone and without an on-site anesthesiologist in the vast majority of patients.


Subject(s)
Anesthesia, Local , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Minimally Invasive Surgical Procedures , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Anesthesia, General , Anesthesia, Local/adverse effects , Anesthesia, Local/mortality , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Conscious Sedation , Feasibility Studies , Female , Humans , Length of Stay , Male , Minimally Invasive Surgical Procedures/adverse effects , Minimally Invasive Surgical Procedures/mortality , Patient Safety , Postoperative Complications/mortality , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
7.
BMC Nephrol ; 21(1): 203, 2020 05 29.
Article in English | MEDLINE | ID: mdl-32471374

ABSTRACT

BACKGROUND: Patients with chronic kidney disease (CKD) reportedly have a high prevalence of aortic valve calcification (AVC). In population-based studies, AVC is considered a manifestation of systemic atherosclerosis. The association of AVC with atherosclerotic lesions has not been fully investigated in predialysis patients. The present study was performed to determine whether carotid artery lesions and peripheral artery disease (PAD) are associated with AVC in patients with CKD not on dialysis. METHODS: In total, 749 patients were included in this cross-sectional study. AVC was evaluated using echocardiography. Carotid artery lesions including carotid artery plaque (CAP) and PAD were simultaneously examined in each patient. A logistic regression analysis was applied to determine the factors associated with AVC. RESULTS: AVC, CAP, and PAD were found in 201, 583, and 123 patients, respectively. In the multivariable analyses adjusted for covariates including the estimated glomerular filtration rate and makers of mineral metabolism (serum calcium, serum phosphorus, parathyroid hormone, 1,25-dihydroxyvitamin D, and fibroblast growth factor 23), AVC was significantly associated with the presence of CAP [odds ratio (OR), 3.37; 95% confidence interval (CI), 1.43-7.95], the presence of PAD (OR, 1.76; 95% CI, 1.10-2.81), the CAP score (per 1.0-point increase) (OR, 1.06; 95% CI, 1.02-1.11), and the ankle-brachial blood pressure index (per 0.1-point increase) (OR, 0.83; 95% CI, 0.72-0.95). CONCLUSIONS: AVC was associated with atherosclerotic lesions independent of kidney function and mineral metabolism. We consider that this association between AVC and atherosclerosis might reflect the burden of shared atherosclerotic risk factors.


Subject(s)
Aortic Valve Stenosis/epidemiology , Aortic Valve/pathology , Calcinosis/epidemiology , Carotid Artery Diseases/epidemiology , Peripheral Arterial Disease/epidemiology , Renal Insufficiency, Chronic/epidemiology , Adult , Aged , Aged, 80 and over , Ankle Brachial Index , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Calcinosis/diagnostic imaging , Calcinosis/physiopathology , Calcium/blood , Carotid Artery Diseases/diagnostic imaging , Carotid Artery Diseases/physiopathology , Cross-Sectional Studies , Echocardiography , Female , Fibroblast Growth Factor-23 , Fibroblast Growth Factors/blood , Humans , Lansoprazole , Male , Middle Aged , Parathyroid Hormone/blood , Phosphorus/blood , Renal Insufficiency, Chronic/physiopathology , Vitamin D/analogs & derivatives , Vitamin D/blood , Young Adult
8.
J Am Heart Assoc ; 9(5): e014446, 2020 03 03.
Article in English | MEDLINE | ID: mdl-32089049

ABSTRACT

Background Left bundle branch block (LBBB) is common after transcatheter aortic valve implantation (TAVI) and is an indicator of subsequent high-grade atrioventricular block (HAVB). No standardized protocol is available to identify LBBB patients at risk for HAVB. The aim of the current study was to evaluate the safety and efficacy of an electrophysiology study tailored strategy in patients with LBBB after TAVI. Methods and Results We prospectively analyzed consecutive patients with LBBB after TAVI. An electrophysiology study was performed to measure the HV-interval the day following TAVI. In patients with normal His-ventricular (HV)-interval ≤55 ms, a loop recorder was implanted (ILR-group), whereas pacemaker implantation was performed in patients with prolonged HV-interval >55 ms (PM-group). The primary end point was occurrence of HAVB during a follow-up of 12 months. Secondary end points were symptoms, hospitalizations, adverse events because of device implantation or electrophysiology study, and death. Of 373 patients screened after TAVI, 56 patients (82±6 years, 41% male) with LBBB were included. HAVB occurred in 4 of 41 patients (10%) in the ILR-group and in 8 of 15 patients (53%) in the PM-group (P<0.001). We did not identify other predictors for HAVB than the HV interval. The negative predictive value for the cut-off of HV 55 ms to detect HAVB was 90%. No HAVB-related syncope occurred in the 2 groups. Conclusions An electrophysiology study tailored strategy to LBBB after TAVI with a cut-off of HV >55 ms is a feasible and safe approach to stratify patients with regard to developing HAVB during a follow-up of 12 months.


Subject(s)
Aortic Valve Stenosis/surgery , Atrioventricular Block/diagnosis , Atrioventricular Block/epidemiology , Bundle-Branch Block/diagnosis , Bundle-Branch Block/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/physiopathology , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Hospitalization , Humans , Male , Predictive Value of Tests , Prospective Studies , Risk Assessment
9.
Catheter Cardiovasc Interv ; 95(1): 45-53, 2020 01.
Article in English | MEDLINE | ID: mdl-31038290

ABSTRACT

OBJECTIVES: To demonstrate safety, feasibility and short-term clinical outcomes after transcatheter aortic valve-in-valve (ViV) implantation under local anesthesia without contrast aortography or echocardiographic guidance. BACKGROUND: Transcatheter ViV implantation is an emerging treatment modality for patients with degenerative surgical bioprostheses. Given the radiopaque properties of the surgical aortic valve (SAV) frame, ViV procedures can often be performed with fluoroscopic guidance alone. METHODS: ViV implantation was performed in 37 patients with SAV failure under local anesthesia without contrast aortography. Clinical and echocardiographic data were obtained at baseline, discharge, and 30 days. RESULTS: Mean age was 74 ± 10 years and STS predicted risk of mortality was 5.6 ± 2.4%. Mean transaortic gradient decreased from 39.4 ± 15.5 mmHg to 13 ± 6.3 mmHg at discharge (p < .001), and 20 ± 7.5 mmHg at 30 days (p < .001 compared to baseline), aortic valve area increased from 0.9 ± 0.3 cm2 to 1.2 ± 0.4 cm2 at 30 days (p = .007). No patient had more than mild aortic regurgitation. Hospital discharge occurred at a median of 2.6 ± 4.4 days. At 30-day follow-up there were no deaths, myocardial infarctions, strokes, repeat hospital admissions for heart failure, or renal failure. One patient (2.7%) required a new pacemaker. 93% of the patients were in New York Heart Association functional class I or II. CONCLUSIONS: Transcatheter aortic ViV implantation for selected patients with degenerative surgical bioprostheses under local anesthesia without aortography or echocardiographic guidance is feasible and safe.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Prosthesis Failure , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Anesthesia, Local , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Feasibility Studies , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
10.
JACC Cardiovasc Imaging ; 12(2): 267-282, 2019 02.
Article in English | MEDLINE | ID: mdl-30732722

ABSTRACT

Up to 40% of patients with aortic stenosis (AS) present with a "discordant grading" usually referred to as "low-gradient AS." This article presents a step-by-step integrative approach overview of the utility, limitations, and complementary role of the different imaging modalities for the assessment of AS severity with a special emphasis on the reconciliation of discordant grading. The first step is to confirm the validity of echocardiographic measures of AS severity. For example, hybrid imaging can combine left ventricular outflow tract area measured by 3-dimensional echocardiography or contrast enhanced multidetector row computed tomography with flow velocities measured by Doppler. The next step is to differentiate severe from non-severe AS with the use of low-dose dobutamine stress echocardiography, especially in patients with low left ventricular ejection fraction, low-flow, low-gradient AS. Aortic valve calcium scoring measured by noncontrast multidetector row computed tomography is preferred in patients with low-gradient AS and preserved left ventricular ejection fraction as well as in those with inconclusive results with dobutamine stress echocardiography.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve/diagnostic imaging , Echocardiography , Multimodal Imaging/methods , Tomography, X-Ray Computed , Aortic Valve/physiopathology , Aortic Valve Stenosis/physiopathology , Humans , Predictive Value of Tests , Reproducibility of Results , Severity of Illness Index
12.
BMC Cardiovasc Disord ; 18(1): 231, 2018 12 10.
Article in English | MEDLINE | ID: mdl-30526521

ABSTRACT

Transcatheter aortic valve implantation (TAVI) has become an established therapeutic option for patients with symptomatic, severe aortic valve stenosis. Ageing of the Western and Asian population and expansion of indications for TAVI will lead to a substantial increase in the number of TAVI procedures performed worldwide within the next decades. In line with the maturation of TAVI over the past few years, there has also been a significant simplification and optimisation of the TAVI procedure. A minimalist TAVI procedure and fast-track TAVI course have been shown to have distinct advantages over the more traditional TAVI approach. The aim of this manuscript is to discuss strategies of TAVI simplification and optimization, with special focus on fast-track TAVI, without compromising safety and efficacy.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Critical Pathways/organization & administration , Delivery of Health Care, Integrated/organization & administration , Outcome and Process Assessment, Health Care/organization & administration , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Clinical Decision-Making , Denmark , Efficiency, Organizational , Health Status , Hemodynamics , Humans , Length of Stay , Patient Safety , Postoperative Complications/prevention & control , Program Development , Program Evaluation , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Workflow
13.
Expert Rev Cardiovasc Ther ; 16(7): 527-536, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29860888

ABSTRACT

INTRODUCTION: Coronary artery calcification (CAC) is reflective of atherosclerotic disease and incrementally predictive of future cardiovascular events (CVE), independent of traditional risk factors. Extra coronary calcium such as aortic valve calcification, which can be identified and quantified by computed tomography (CT) imaging, has shown to predict future CVE in both asymptomatic and symptomatic (i.e. stable angina and acute coronary syndrome [ACS]) settings. It has hence been a vital tool in studies involving new therapies for cardiovascular disease. Areas covered: In this review, promising therapies on the horizon are reviewed, along with the role of cardiac CT and coronary calcification in these studies. A Medline search for peer-reviewed publications using keywords related to coronary calcium score, aortic valve calcium, and therapies targeting the same was carried out. Expert commentary: CT scanning provides a distinct means of detecting and quantifying coronary plaque as well as valvular calcification with excellent reproducibility. Based on voluminous data available, the absence of coronary calcium serves as a factor to de-risk patients for cardiovascular risk stratification and management algorithms. Newer therapies have shown to lower progression of coronary calcification, thus being beneficial in slowing progression of atherosclerotic disease. As British Epidemiologist Geoffrey Rose states, the best predictor of a life-threatening disease is the early manifestation of that disease. As CAC represents the early manifestation of atherosclerosis, it is the best-known stratifier of risk today, and its clinical use will continue to rise.


Subject(s)
Aortic Valve Stenosis/physiopathology , Aortic Valve/pathology , Calcinosis/physiopathology , Coronary Artery Disease/physiopathology , Vascular Calcification/physiopathology , Aortic Valve/physiopathology , Coronary Artery Disease/therapy , Humans , Plaque, Atherosclerotic/physiopathology , Reproducibility of Results , Risk Factors , Tomography, X-Ray Computed , Vascular Calcification/therapy
15.
Cardiovasc Revasc Med ; 19(5 Pt A): 536-539, 2018 07.
Article in English | MEDLINE | ID: mdl-29352701

ABSTRACT

Trancatheter heart valve (THV) thrombosis is effectively treated with anticoagulation but alternative therapies are required when a faster gradient reduction is needed. Open heart surgery has been rarely performed due to the high perioperative mortality and only five cases have been described so far. Here we describe a case of emergent surgical explantation for THV thrombosis after a valve-in-valve. A 67years old man underwent transcatheter aortic valve implantation for a failed surgical bioprosthesis Epic 21mm (St. Jude Medical; St. Paul, Minnesota, US). A CoreValve 23mm (Medtronic, Minneapolis, Minnesota, US) was implanted through femoral access under conscious sedation without complications. Mean transvalvular gradient was effectively reduced (33mmHg vs 16mmHg) with no more than mild residual aortic regurgitation. After 8days the patient was discharged on dual antiplatelet therapy but was readmitted to the intensive care unit for pulmonary oedema 13days later. Echocardiography showed a raised transvalvular mean gradient (mean gradient change from discharge=15mmHg) without aortic regurgitation. Heart Team decided for emergent open heart surgery for the hemodynamic instability. On direct inspection THV was well positioned inside the surgical bioprosthesis but two cusps were covered by thrombus which markedly restricted their mobility. The THV and the former surgical valve were explanted and a new larger stented bioprosthesis was implanted. Thrombosis of the THV was confirmed on microscopic examination which showed no signs of inflammation or degeneration. The patient was discharged after 1month and the 3month follow up showed stable transvalvular gradients.


Subject(s)
Anticoagulants/administration & dosage , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Device Removal , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Thrombosis/surgery , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/physiopathology , Biopsy , Echocardiography , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Humans , Male , Prosthesis Design , Prosthesis Failure , Thrombosis/diagnostic imaging , Thrombosis/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
16.
Catheter Cardiovasc Interv ; 91(2): 330-342, 2018 02 01.
Article in English | MEDLINE | ID: mdl-28738447

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is typically performed under general anesthesia (GA). However, there is increasing data supporting the safety of performing TAVR under local anesthesia/conscious sedation (LA). We performed a meta-analysis to gain better understanding of the safety and efficacy of LA versus GA in patients with severe aortic stenosis undergoing TAVR. METHODS AND RESULTS: We comprehensively searched EMBASE, PubMed, and Web of Science. Effect sizes were summarized using risk ratios (RRs) difference of the mean (DM), and 95% CIs (confidence intervals) for dichotomous and continuous variables respectively. Twenty-six studies and 10,572 patients were included in the meta-analysis. The use of LA for TAVR was associated with lower overall 30-day mortality (RR, 0.73; 95% CI, 0.57-0.93; P = 0.01), use of inotropic/vasopressor drugs (RR, 0.45; 95% CI, 0.28-0.72; P < 0.001), hospital length of stay (LOS) (DM, -2.09; 95% CI, -3.02 to -1.16; P < 0.001), intensive care unit LOS (DM, -0.18; 95% CI, -0.31 to -0.04; P = 0.01), procedure time (DM, -25.02; 95% CI, -32.70 to -17.35; P < 0.001); and fluoroscopy time (DM, -1.63; 95% CI, -3.02 to -0.24; P = 0.02). No differences were observed between LA and GA for stroke, cardiovascular mortality, myocardial infarction, permanent pacemaker implantation, acute kidney injury, paravalvular leak, vascular complications, major bleeding, procedural success, conduction abnormalities, and annular rupture. CONCLUSION: Our meta-analysis suggests that use of LA for TAVR is associated with a lower 30-day mortality, shorter procedure time, fluoroscopy time, ICU LOS, hospital length of stay, and reduced need for inotropic support.


Subject(s)
Anesthesia, General , Anesthesia, Local , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Anesthesia, General/adverse effects , Anesthesia, General/mortality , Anesthesia, Local/adverse effects , Anesthesia, Local/mortality , Aortic Valve/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Humans , Length of Stay , Male , Operative Time , Postoperative Complications/therapy , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
17.
Int J Mol Sci ; 18(8)2017 Jul 31.
Article in English | MEDLINE | ID: mdl-28758988

ABSTRACT

Galectin-3 (Gal-3) is involved in cardiovascular fibrosis and aortic valve (AV) calcification. We hypothesized that Gal-3 pharmacological inhibition with modified citrus pectin (MCP) could reduce aortic and AV remodeling in normotensive rats with pressure overload (PO). Six weeks after aortic constriction, vascular Gal-3 expression was up-regulated in male Wistar rats. Gal-3 overexpression was accompanied by an increase in the aortic media layer thickness, enhanced total collagen, and augmented expression of fibrotic mediators. Further, vascular inflammatory markers as well as inflammatory cells content were greater in aorta from PO rats. MCP treatment (100 mg/kg/day) prevented the increase in Gal-3, media thickness, fibrosis, and inflammation in the aorta of PO rats. Gal-3 levels were higher in AVs from PO rats. This paralleled enhanced AV fibrosis, inflammation, as well as greater expression of calcification markers. MCP treatment prevented the increase in Gal-3 as well as fibrosis, inflammation, and calcification in AVs. Overall, Gal-3 is overexpressed in aorta and AVs from PO rats. Gal-3 pharmacological inhibition blocks aortic and AV remodeling in experimental PO. Gal-3 could be a new therapeutic approach to delay the progression and the development of aortic remodeling and AV calcification in PO.


Subject(s)
Aorta , Aortic Valve Stenosis , Aortic Valve/pathology , Calcinosis , Galectin 3 , Gene Expression Regulation/drug effects , Pectins/pharmacology , Animals , Aorta/metabolism , Aorta/physiopathology , Aortic Valve/drug effects , Aortic Valve/metabolism , Aortic Valve/physiopathology , Aortic Valve Stenosis/metabolism , Aortic Valve Stenosis/pathology , Aortic Valve Stenosis/physiopathology , Calcinosis/metabolism , Calcinosis/pathology , Calcinosis/physiopathology , Disease Models, Animal , Galectin 3/antagonists & inhibitors , Galectin 3/biosynthesis , Male , Rats , Rats, Wistar
18.
Methodist Debakey Cardiovasc J ; 13(2): 73-75, 2017.
Article in English | MEDLINE | ID: mdl-28740586

ABSTRACT

This is a case of a 54-year-old female with a history of mechanical aortic valve replacement who presented in cardiogenic shock. Her primary care provider started her on rivaroxaban for anticoagulation therapy. An urgent transesophageal echocardiogram revealed a significant gradient and thrombosis on one leaflet of the valve that was immobile. Given that she was not a surgical candidate, she underwent thrombolysis. However, she later died due to complications from the thrombotic valve. The utility of target-specific oral anticoagulants has yet to be established in clinical practice.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Factor Xa Inhibitors/therapeutic use , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Rivaroxaban/therapeutic use , Thrombosis/etiology , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Echocardiography, Doppler, Color , Echocardiography, Transesophageal , Fatal Outcome , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Middle Aged , Off-Label Use , Thrombolytic Therapy , Thrombosis/diagnostic imaging , Thrombosis/drug therapy , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL