1.
Phys Med Biol ; 69(10)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38565123

ABSTRACT

Objective.To evaluate the reduction in energy dependence and aging effect of the lithium salt of pentacosa-10,-12-diynoic acid (LiPCDA) films with additives including aluminum oxide (Al2O3), propyl gallate (PG), and disodium ethylenediaminetetracetate (EDTA).Approach. LiPCDA films exhibited energy dependence on kilovoltage (kV) and megavoltage (MV) photon energies and experienced deterioration over time. Evaluations were conducted with added Al2O3and antioxidants to mitigate these issues, and films were produced with and without Al2O3to assess energy dependence. The films were irradiated at doses of 0, 3, 6, and 12 cGy at photon energies of 75 kV, 105 kV, 6 MV, 10 MV, and 15 MV. For the energy range of 75 kV to 15 MV, the mean and standard deviation (std) were calculated and compared for the values normalized to the net optical density (netOD) at 6 MV, corresponding to identical dose levels. To evaluate the aging effect, PG and disodium EDTA were incorporated into the films: sample C with 1% PG, sample D with 2% PG, sample E with 0.62% disodium EDTA added to sample D, and sample F with 1.23% disodium EDTA added to sample D.Main results. Films containing Al2O3demonstrated a maximum 15.8% increase in mean normalized values and a 15.1% reduction in std, reflecting a greater netOD reduction at kV than MV energies, which indicates less energy dependence in these films. When the OD of sample 1-4 depending on the addition of PG and disodium EDTA, was observed for 20 weeks, the transmission mode decreased by 8.7%, 8.3%, 29.3%, and 27.3%, respectively, while the reflection mode was 5.4%, 3.0%, 37.0%, and 34.5%, respectively.Significance. Al2O3effectively reduced the voltage and MV energy dependence. PG was more effective than disodium EDTA in preventing the deterioration of film performance owing to the aging effect.


Subject(s)
Film Dosimetry , Film Dosimetry/instrumentation , Film Dosimetry/methods , Aluminum Oxide/chemistry , Edetic Acid/chemistry , Propyl Gallate , Photons
2.
Sci Rep ; 11(1): 684, 2021 01 12.
Article in English | MEDLINE | ID: mdl-33436878

ABSTRACT

Narrow band ultraviolet B (NB UVB) radiation doses are administered during phototherapy for various dermatological ailments. Precise quantification of these doses is vital because the absorbed irradiation can cause adverse photochemical reactions which can lead to potential phototherapeutic side effects. The paper presents development of diacetylene based dosimeter for the determination of therapeutic NB UVB doses during phototherapy. The amide terminated diacetylene analogues have been synthesized by tailoring them with different functional groups. The synthesized diacetylene monomers have been introduced in a polyvinyl alcohol binder solution to obtain a film dosimeter. The influence of different headgroups on the colorimetric response to UV radiation has been studied. Among all the synthesized diacetylene analogues, the naphthylamine substituted diacetylene exhibited excellent color transition from white to blue color at 100 mJ cm-2 NB UVB radiation dose. The developed amide films can be easily pasted on multiple sites of the patient's skin to monitor doses during phototherapy simultaneously at different anatomical regions. The digital image processing of the scanned images of the irradiated films facilitates rapid dose measurement which enables facile implementation of the developed film dosimeters and promising application in routine clinical dosimetry.


Subject(s)
Film Dosimetry/instrumentation , Skin Diseases/radiotherapy , Skin/radiation effects , Ultraviolet Therapy/methods , Whole-Body Irradiation/methods , Acetylene/chemistry , Film Dosimetry/methods , Humans , Radiation Dosage
3.
Med Phys ; 47(3): 1305-1316, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31837272

ABSTRACT

PURPOSE: Current techniques and procedures for dosimetry in microbeams typically rely on radiochromic film or small volume ionization chambers for validation and quality assurance in 2D and 1D, respectively. Whilst well characterized for clinical and preclinical radiotherapy, these methods are noninstantaneous and do not provide real time profile information. The objective of this work is to determine the suitability of the newly developed vM1212 detector, a pixelated CMOS (complementary metal-oxide-semiconductor) imaging sensor, for in situ and in vivo verification of x-ray microbeams. METHODS: Experiments were carried out on the vM1212 detector using a 220 kVp small animal radiation research platform (SARRP) at the Helmholtz Centre Munich. A 3 x 3 cm2 square piece of EBT3 film was placed on top of a marked nonfibrous card overlaying the sensitive silicon of the sensor. One centimeter of water equivalent bolus material was placed on top of the film for build-up. The response of the detector was compared to an Epson Expression 10000XL flatbed scanner using FilmQA Pro with triple channel dosimetry. This was also compared to a separate exposure using 450 µm of silicon as a surrogate for the detector and a Zeiss Axio Imager 2 microscope using an optical microscopy method of dosimetry. Microbeam collimator slits with range of nominal widths of 25, 50, 75, and 100 µm were used to compare beam profiles and determine sensitivity of the detector and both film measurements to different microbeams. RESULTS: The detector was able to measure peak and valley profiles in real-time, a significant reduction from the 24 hr self-development required by the EBT3 film. Observed full width at half maximum (FWHM) values were larger than the nominal slit widths, ranging from 130 to 190 µm due to divergence. Agreement between the methods was found for peak-to-valley dose ratio (PVDR), peak to peak separation and FWHM, but a difference in relative intensity of the microbeams was observed between the detectors. CONCLUSIONS: The investigation demonstrated that pixelated CMOS sensors could be applied to microbeam radiotherapy for real-time dosimetry in the future, however the relatively large pixel pitch of the vM1212 detector limit the immediate application of the results.


Subject(s)
Film Dosimetry/methods , Metals/chemistry , Oxides/chemistry , Silicon/chemistry , Animals , Equipment Design , Humans , Microscopy , Phantoms, Imaging , Quality Assurance, Health Care , Radiotherapy Dosage , Radiotherapy, High-Energy , Semiconductors , Surface Properties , X-Rays
4.
Med Phys ; 45(4): 1699-1707, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29399810

ABSTRACT

PURPOSE: Brachytherapy with 106 Ru/106 Rh plaques offers good outcomes for small-to-medium choroidal melanomas and retinoblastomas. The dose measurement of the plaques is challenging, due to the small range of the emitted beta particles and steep dose gradients involved. The scarce publications on film dosimetry of 106 Ru/106 Rh plaques used solid phantoms. This work aims to develop a practical method for measuring the absorbed dose distribution in water produced by 106 Ru/106 Rh plaques using EBT3 radiochromic film. METHODS: Experimental setups were developed to determine the dose distribution at a plane perpendicular to the symmetry axis of the plaque and at a plane containing the symmetry axis. One CCA and two CCX plaques were studied. The dose maps were obtained with the FilmQA Pro 2015 software, using the triple-channel dosimetry method. The measured dose distributions were compared to published Monte Carlo simulation and experimental data. RESULTS: A good agreement was found between measurements and simulations, improving upon published data. Measured reference dose rates agreed within the experimental uncertainty with data obtained by the manufacturer using a scintillation detector, with typical differences below 5%. The attained experimental uncertainty was 4.1% (k = 1) for the perpendicular setup, and 7.9% (k = 1) for the parallel setup. These values are similar or smaller than those obtained by the manufacturer and other authors, without the need of solid phantoms that are not available to most users. CONCLUSIONS: The proposed method may be useful to the users to perform quality assurance preclinical tests of 106 Ru/106 Rh plaques.


Subject(s)
Brachytherapy , Eye/radiation effects , Film Dosimetry , Radiation Dosage , Radioisotopes/therapeutic use , Rhodium/therapeutic use , Ruthenium Radioisotopes/therapeutic use , Water , Monte Carlo Method , Radiotherapy Dosage
5.
Phys Med Biol ; 63(2): 025010, 2018 01 09.
Article in English | MEDLINE | ID: mdl-29134951

ABSTRACT

Phototherapy treatment using ultraviolet (UV) A and B light sources has long existed as a treatment option for various skin conditions. Quality control for phototherapy treatment recommended by the British Association of Dermatologists and British Photodermatology Group generally focused on instrumentation-based dosimetry measurements. The purpose of this study was to present an alternative, easily prepared dosimeter system for the measurement of UV dose and as a simple quality assurance technique for phototherapy treatments. Five different UVA-sensitive radiochromic dosimeter formulations were investigated and responded with a measurable and visible optical change both in solution and in gel form. Iron(III) reduction reaction formulations were found to be more sensitive to UVA compared to iron(II) oxidation formulations. One iron(III) reduction formulation was found to be especially promising due to its sensitivity to UVA dose, ease of production, and linear response up to a saturation point.


Subject(s)
Film Dosimetry/methods , Iron/chemistry , Phototherapy , Ultraviolet Rays , Dose-Response Relationship, Radiation , Film Dosimetry/instrumentation , Gels/chemistry , Humans , Image Processing, Computer-Assisted
6.
Phys Med Biol ; 62(2): 377-393, 2017 01 21.
Article in English | MEDLINE | ID: mdl-27997377

ABSTRACT

We investigated the dose-response of the external beam therapy 3 (EBT3) films for proton and carbon ion clinical beams, in comparison with conventional radiotherapy beams; we also measured the film response along the energy deposition-curve in water. We performed measurements at three hadrontherapy centres by delivering monoenergetic pencil beams (protons: 63-230 MeV; carbon ions: 115-400 MeV/u), at 0.4-20 Gy dose to water, in the plateau of the depth-dose curve. We also irradiated the films to clinical MV-photon and electron beams. We placed the EBT3 films in water along the whole depth-dose curve for 148.8 MeV protons and 398.9 MeV/u carbon ions, in comparison with measurements provided by a plane-parallel ionization chamber. For protons, the response of EBT3 in the plateau of the depth-dose curve is not different from that of photons, within experimental uncertainties. For carbon ions, we observed an energy dependent under-response of EBT3 film, from 16% to 29% with respect to photon beams. Moreover, we observed an under-response in the Bragg peak region of about 10% for 148.8 MeV protons and of about 42% for 398.9 MeV/u carbon ions. For proton and carbon ion clinical beams, an under-response occurs at the Bragg peak. For carbon ions, we also observed an under-response of the EBT3 in the plateau of the depth-dose curve. This effect is the highest at the lowest initial energy of the clinical beams, a phenomenon related to the corresponding higher LET in the film sensitive layer. This behavior should be properly modeled when using EBT3 films for accurate 3D dosimetry.


Subject(s)
Carbon/therapeutic use , Film Dosimetry/instrumentation , Film Dosimetry/methods , Proton Therapy , Calibration , Humans , Radiation Dosage , Radiometry/methods , Uncertainty , Water
7.
Phys Med Biol ; 61(21): 7551-7570, 2016 11 07.
Article in English | MEDLINE | ID: mdl-27716632

ABSTRACT

This work evaluates the dosimetric properties of newly developed optically stimulated luminescence (OSL) films, fabricated with either Al2O3:C or Al2O3:C,Mg, using a prototype laser scanning reader, a developed image reconstruction algorithm, and a 6 MV therapeutic photon beam. Packages containing OSL films (Al2O3:C and Al2O3:C,Mg) and a radiochromic film (Gafchromic EBT3) were irradiated using a 6 MV photon beam using different doses, field sizes, with and without wedge filter. Dependence on film orientation of the OSL system was also tested. Diode-array (MapCHECK) and ionization chamber measurements were performed for comparison. The OSLD film doses agreed with the MapCHECK and ionization chamber data within the experimental uncertainties (<2% at 1.5 Gy). The system background and minimum detectable dose (MDD) were <0.5 mGy, and the dose response was approximately linear from the MDD up to a few grays (the linearity correction was <10% up to ~2-4 Gy), with no saturation up to 30 Gy. The dose profiles agreed with those obtained using EBT3 films (analyzed using the triple channel method) in the high dose regions of the images. In the low dose regions, the dose profiles from the OSLD films were more reproducible than those from the EBT3 films. We also demonstrated that the OSL film data are independent on scan orientation and field size over the investigated range. The results demonstrate the potential of OSLD films for 2D dosimetry, particularly for the characterization of small fields, due to their wide dynamic range, linear response, resolution and dosimetric properties. The negligible background and potential simple calibration make these OSLD films suitable for remote audits. The characterization presented here may motivate further commercial development of a 2D dosimetry system based on the OSL from Al2O3:C or Al2O3:C,Mg.


Subject(s)
Algorithms , Aluminum Oxide/chemistry , Film Dosimetry/instrumentation , Luminescent Measurements/instrumentation , Optics and Photonics , Calibration , Dose-Response Relationship, Radiation , Film Dosimetry/methods
8.
Med Phys ; 41(7): 072101, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24989396

ABSTRACT

PURPOSE: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. METHODS: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. RESULTS: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement area for the I-125 irradiations, the accuracy of the calibration curve was degraded due to the presence of localized film heterogeneities. No degradation in the calibration curves was found when reducing the number of calibration points down to only 4, but with piecewise fitting, 6 calibration points as well as a blank film are required. Variations due to photon energy in film optical density of up to 3% were found above doses of 2 Gy. CONCLUSIONS: A modified procedure for performing EBT3 film calibration was established for use with low-energy brachytherapy seeds and high dose exposures. The energy dependence between 6 MV and I-125 photons is significant such that film calibrations should be done with an appropriately low-energy source when performing low-energy brachytherapy dose measurements. Two-segment piecewise fitting with the inclusion of errors in measured optical density as well as dose was found to result in the most accurate calibration curves. Above doses of 1 Gy, absolute dose measurements can be made with an accuracy of 1.6% for 6 MV beams and 5.7% for I-125 seed exposures if using the I-125 source for calibration, or 2.3% if using the 75 kVp photon beam for calibration.


Subject(s)
Brachytherapy , Calibration , Film Dosimetry/methods , Radiotherapy Dosage , Algorithms , Brachytherapy/instrumentation , Iodine Radioisotopes , Phantoms, Imaging , Photons , Polymethyl Methacrylate , Software , Uncertainty
9.
Med Phys ; 41(6): 061715, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24877810

ABSTRACT

PURPOSE: Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In this work, the authors investigate the accuracy and efficiency of an end-to-end MERT plan and automated delivery method. METHODS: Treatment planning was initiated on a previously treated whole breast irradiation case including an electron boost. All dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. RESULTS: The automated delivery, which covered four electron energies, 196 subfields, and 6183 total MU was completed in 25.8 min, including 6.2 min of beam-on time. The remainder of the delivery time was spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. Comparison of the planned and delivered film dose gave 3%/3mm gamma pass rates of 62.1%, 99.8%, 97.8%, 98.3%, and 98.7% for the 9, 12, 16, and 20 MeV, and combined energy deliveries, respectively. Delivery was also performed with a MapCHECK device and resulted in 3%/3 mm gamma pass rates of 88.8%, 86.1%, 89.4%, and 94.8% for the 9, 12, 16, and 20 MeV energies, respectively. CONCLUSIONS: Results of the authors' study showed that an accurate delivery utilizing an add-on tertiary electron collimator is possible using Monte Carlo calculated plans and inverse optimization, which brings MERT closer to becoming a viable option for physicians in treating superficial malignancies.


Subject(s)
Electrons/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy/methods , Breast/radiation effects , Breast Neoplasms/radiotherapy , Film Dosimetry , Humans , Models, Biological , Monte Carlo Method , Phantoms, Imaging , Radiotherapy/instrumentation , Radiotherapy Dosage , Water
10.
Med Phys ; 39(10): 6111-7, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23039650

ABSTRACT

PURPOSE: Radiosurgery uses small fields and high-radiation doses to treat intra- and extracranial lesions in a single session. The lack of a lateral electronic equilibrium and the presence of high-dose gradients in these fields are challenges for adequate measurements. The availability of radiation detectors with the high spatial resolution required is restricted to only a few. Stereotactic diodes and EBT radiochromic films have been demonstrated to be good detectors for small-beam dosimetry. Because the stereotactic diode is the standard measurement for the dosimetry of radiosurgical beams, the goal of this work was to perform measurements with the radiochromic film Gafchromic(®) EBT2 and compare its results with a stereotactic diode. METHODS: Total scatter factors, tissue maximum, and off-axis ratios from a 6 MV small photon beams were measured using EBT2 radiochromic film in a water phantom. The film-measured data were evaluated by comparing it with the data measured with a stereotactic field diode (IBA-Dosimetry). RESULTS: The film and diode measurements had excellent agreement. The differences between the detectors were less than or equal to 2.0% for the tissue maximum and the off-axis ratios. However, for the total scatter factors, there were significant differences, up to 4.9% (relative to the reference field), for field sizes less than 1.0 cm. CONCLUSIONS: This work found that the Gafchromic(®) EBT2 film is adequate for small photon beam measurements, particularly for tissue maximum and off-axis ratios. However, careful attention must be taken when measuring output factors of small beams below 1.0 cm due to the film's energy dependence. The measurement differences may be attributable to the film's active layer composition because EBT2 incorporates higher Z elements (i.e., bromide and potassium), hence revealing a potential energy dependence for the dosimetry of small photon beams.


Subject(s)
Film Dosimetry/methods , Radiosurgery/methods , Calibration , Film Dosimetry/instrumentation , Photons/therapeutic use , Uncertainty
11.
Radiat Oncol ; 6: 85, 2011 Jul 20.
Article in English | MEDLINE | ID: mdl-21774795

ABSTRACT

BACKGROUND: To present the results of quality assurance (QA) in IMRT of film dosimetry and ionization chambers measurements with an eight year follow-up. METHODS: All treatment plans were validated under the linear accelerator by absolute and relative measures obtained with ionization chambers (IC) and with XomatV and EDR2 films (Kodak). RESULTS: The average difference between IC measured and computed dose at isocenter with the gantry angle of 0° was 0.07 ± 1.22% (average ± 1 SD) for 2316 prostate, 1.33 ± 3.22% for 808 head and neck (h&n), and 0.37 ± 0.62% for 108 measurements of prostate bed fields. Pelvic treatment showed differences of 0.49 ± 1.86% in 26 fields for prostate cases and 2.07 ± 2.83% in 109 fields of anal canal.Composite measurement at isocenter for each patient showed an average difference with computed dose of 0.05 ± 0.87% for 386 prostate, 1.49 ± 1.86% for 158 h&n, 0.37 ± 0.34% for 23 prostate bed, 0.80 ± 0.28% for 4 pelvis, and 2.31 ± 0.56% for 17 anal canal cases. On the first 250 h&n analyzed by film in absolute dose, the average of the points crossing a gamma index 3% and 3 mm was 93%. This value reached 99% for the prostate fields. CONCLUSION: More than 3500 beams were found to be within the limits defined as validated for treatment between 2001 and 2008.


Subject(s)
Film Dosimetry/methods , Prostatic Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Algorithms , Anus Neoplasms/diagnostic imaging , Cancer Care Facilities , Follow-Up Studies , Humans , Male , Pelvic Neoplasms/radiotherapy , Quality Assurance, Health Care , Radiography , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Software
12.
Photochem Photobiol ; 86(5): 1174-8, 2010.
Article in English | MEDLINE | ID: mdl-20573044

ABSTRACT

The objective of the study was to compare Bacillus subtilis spore film dosimeters with a Robertson Berger UV meter (RB meter) and diary records for assessing personal UV-B doses during a 13-day heliotherapy (HT) for atopic dermatitis (AD). In addition, the relationship between the personal UV-B dose and change in serum 25-hydroxyvitamin D (25(OH)D) was studied. Altogether 21 adult patients with AD completed the study arranged in the Canary Islands, either in January or March 2005. The spore film dosimeters were used throughout the day during the HT. Serum 25(OH)D was analyzed using radioimmunoassay. The mean personal UV-B dose measured with the dosimeters was 75 SED in January and 131 SED in March. The respective results gained from the RB meter combined with diary records were 63 SED and 119 SED showing a close correlation with the dosimeter results. Serum 25(OH)D concentration increased by 9.7nmol L(-1) in January and by 26.0 7nmol L(-1) in March. The increase in serum 25(OH)D correlated with the UV-B dose received. The patients complied well to use the dosimeters. We conclude spore films to be a feasible and reliable personal UV dosimeter in vivo in field conditions.


Subject(s)
Bacillus subtilis , Film Dosimetry , Heliotherapy , Spores , Ultraviolet Rays , Adult , Dermatitis, Atopic/radiotherapy , Dose-Response Relationship, Radiation , Female , Film Dosimetry/instrumentation , Humans , Male
13.
J Appl Clin Med Phys ; 12(1): 3360, 2010 Dec 02.
Article in English | MEDLINE | ID: mdl-21330985

ABSTRACT

High dose rate (HDR) brachytherapy is one of the accepted treatment modalities in gastro-intestinal tract and bladder carcinomas. Considering the shortcoming of contact brachytherapy routinely used in gastrointestinal tract in treatment of big tumors or invasive method of bladder treatment, an intraluminal applicator with the capability of insertion into the tumor depth seems to be useful. This study presents some dosimetric evaluations to introduce this applicator to the clinical use. The radiation attenuation characteristics of the applicator were evaluated by means of two dosimetric methods including well-type chamber and radiochromic film. The proposed 110 cm long applicator has a flexible structure made of stainless steel for easy passage through lumens and a needle tip to drill into big tumors. The 2mm diameter of the applicator is thick enough for source transition, while easy passage through any narrow lumen such as endoscope or cystoscope working channel is ensured. Well-chamber results showed an acceptably low attenuation of this steel springy applicator. Performing absolute dosimetry resulted in a correlation coefficient of R = 0.9916 (p-value ≈ 10-7) between standard interstitial applicator and the one proposed in this article. This study not only introduces a novel applicator with acceptable attenuation but also proves the response independency of the GAFCHROMIC EBT films to energy. By applying the dose response of the applicator in the treatment planning software, it can be used as a new intraluminal / interstitial applicator.


Subject(s)
Brachytherapy/methods , Film Dosimetry/methods , Gastrointestinal Neoplasms/radiotherapy , Urinary Bladder Neoplasms/radiotherapy , Brachytherapy/classification , Brachytherapy/instrumentation , Calibration , Chromium Compounds/chemistry , Film Dosimetry/instrumentation , Humans , Iridium Radioisotopes/therapeutic use , Radiotherapy Dosage , Software , Stainless Steel/chemistry
14.
Med Phys ; 36(11): 5027-32, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19994513

ABSTRACT

PURPOSE: The AccuBoost brachytherapy system applies HDR 192Ir beams peripherally to the breast using collimating applicators. The purpose of this study was to benchmark Monte Carlo simulations of the HDR 192Ir source, to dosimetrically characterize the round applicators using established Monte Carlo simulation and radiation measurement techniques and to gather data for clinical use. METHODS: Dosimetric measurements were performed in a polystyrene phantom, while simulations estimated dose in air, liquid water, polystyrene and ICRU 44 breast tissue. Dose distribution characterization of the 4-8 cm diameter collimators was performed using radiochromic EBT film and air ionization chambers. RESULTS: The central axis dose falloff was steeper for the 4 cm diameter applicator in comparison to the 8 cm diameter applicator, with surface to 3 cm depth-dose ratios of 3.65 and 2.44, respectively. These ratios did not considerably change when varying the phantom composition from breast tissue to polystyrene, phantom thickness from 4 to 8 cm, or phantom radius from 8 to 15 cm. Dose distributions on the central axis were fitted to sixth-order polynomials for clinical use in a hand calculation spreadsheet (i.e., nomogram). Dose uniformity within the useful applicator apertures decreased as depth-dose increased. CONCLUSIONS: Monte Carlo benchmarking simulations of the HDR 192Ir source using the MCNP5 radiation transport code indicated agreement within 1% of the published results over the radial/angular region of interest. Changes in phantom size and radius did not cause noteworthy changes in the central axis depth-dose. Polynomial fit depth-dose curves provide a simple and accurate basis for a nomogram.


Subject(s)
Brachytherapy/instrumentation , Brachytherapy/methods , Breast Neoplasms/radiotherapy , Iridium Radioisotopes/therapeutic use , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Air , Computer Simulation , Female , Film Dosimetry , Humans , Monte Carlo Method , Phantoms, Imaging , Polystyrenes , Radiotherapy Dosage , Water
15.
Med Phys ; 35(8): 3787-99, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18777938

ABSTRACT

Radiochromic film dosimetry has been extensively used for intravascular brachytherapy applications for near field within 1 cm from the sources. With the recent introduction of new model of radiochromic films, GAFCHROMIC EBT, with higher sensitivity than earlier models, it is promising to extend the distances out to 5 cm for low dose rate (LDR) source dosimetry. In this study, the use of new model GAFCHROMIC EBT film for 125I seed dosimetry in Solid Water was evaluated for radial distances from 0.06 cm out to 5 cm. A multiple film technique was employed for four 125I seeds (Implant Sciences model 3500) with NIST traceable air kerma strengths. Each experimental film was positioned in contact with a 125I seed in a Solid Water phantom. The products of the air kerma strength and exposure time ranged from 8 to 3158 U-h, with the initial air kerma strength of 6 U in a series of 25 experiments. A set of 25 calibration films each was sequentially exposed to one 125I seed at about 0.58 cm distance for doses from 0.1 to 33 Gy. A CCD camera based microdensitometer, with interchangeable green (520 nm) and red (665 nm) light boxes, was used to scan all the films with 0.2 mm pixel resolution. The dose to each 125I calibration film center was calculated using the air kerma strength of the seed (incorporating decay), exposure time, distance from seed center to film center, and TG43U1S1 recommended dosimetric parameters. Based on the established calibration curve, dose conversion from net optical density was achieved for each light source. The dose rate constant was determined as 0.991 cGy U(-1)h(-1) (+/-6.9%) and 1.014 cGy U(-1)h(-1) (+/-6.8%) from films scanned using green and red light sources, respectively. The difference between these two values was within the uncertainty of the measurement. Radial dose function and 2D anisotropy function were also determined. The results obtained using the two light sources corroborated each other. We found good agreement with the TG43U1S1 recommended values of radial dose function and 2D anisotropy function, to within the uncertainty of the measurement. We also verified the dosimetric parameters in the near field calculated by Rivard using Monte Carlo method. The radial dose function values in Solid Water were lower than those in water recommended by TG43U1S1, by about 2%, 3%, 7%, and 14% at 2, 3, 4, and 5 cm, respectively, partially due to the difference in the phantom material composition. Radiochromic film dosimetry using GAFCHROMIC EBT model is feasible in determining 2D dose distributions around low dose rate 125I seed. It is a viable alternative to TLD dosimetry for 125I seed dose characterization.


Subject(s)
Brachytherapy/methods , Film Dosimetry/methods , Iodine Radioisotopes/therapeutic use , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Anisotropy , Brachytherapy/instrumentation , Calibration , Film Dosimetry/instrumentation , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/instrumentation , Reproducibility of Results , Sensitivity and Specificity , Water
16.
Acta Neurochir (Wien) ; 150(2): 161-4; discussion 164, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18213438

ABSTRACT

OBJECTIVE: To test a new hypothesis that the glue/contrast admixture used for embolisation reduces the dose delivered to AVMs using an experimental model. METHOD: A model was created using a block of "solid water" (6 x 5 x 2 cm) with twelve wells of different depths. Different concentrations of the glue admixture (Enbucrilate + Lipiodol) were used. The model was irradiated using a 5MV beam with a clinical LINAC system and the dose was checked upstream and downstream. Dose was measured using Kodak XV film, a Vidar 16 bit film scanner and software for therapeutic film dosimetry measurements (RIT software). RESULTS: The radiation dose varied with the distance beyond the glue solid water interface. For distances of 0, 2 and 5 mm to the film, the mean reduction was 13.65% (SD = 2.94), 6.87% (SD = 1.95) and 1.75% (SD = 1.14), respectively. There was also correlation with the Lipiodol concentration in the mixture. The maximum reductions for 80, 50 and 20% Lipiodol concentrations were 16.1% (SD = 1.32), 14.85% (SD = 0.98) and 10% (SD = 1.21), respectively. There was no correlation between the glue depth and the dose delivered. CONCLUSION: The hypothesis that the glue mixture used for embolisation reduces the radiation dose delivered was experimentally confirmed with this study.


Subject(s)
Arteriovenous Malformations/therapy , Contrast Media/pharmacology , Embolization, Therapeutic , Enbucrilate/pharmacology , Iodized Oil/pharmacology , Radiation Dosage , Film Dosimetry , Humans , Models, Cardiovascular , Radiosurgery
17.
Med Phys ; 34(8): 3345-57, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17879798

ABSTRACT

The performances of two generations of computed radiography (CR) were tested and compared in terms of resolution and noise characteristics. The main aim was to characterize and quantify the noise sources in the images. The systems tested were (1) Agfa CR 25.0, a flying spot reader with powder phosphor image plates (MD 40.0); and (2) the Agfa DX-S, a line-scanning CR reader with needle crystal phosphor image plates (HD 5.0). For both systems, the standard metrics of presampled modulation transfer function (MTF), normalized noise power spectra (NNPS) and detective quantum efficiency (DQE) were measured using standard radiation quality RQA5 as defined by the International Electrotechnical Commission. The various noise sources contributing to the NNPS were separated by using knowledge of their relationship with air kerma, MTF, absorption efficiency and antialiasing filters. The DX-S MTF was superior compared with the CR 25.0. The maximum difference in MTF between the DX-S scan and CR 25.0 subscan directions was 0.13 at 1.3 mm(-1). For a nominal detector air kerma of 4 microGy, the peak DQE of the DX-S was 43 (+/-3)%, which was over double that of the CR 25.0 of 18 (+/-2)%. The additive electronic noise was negligible on the CR 25.0 but calculated to be constant 3.4 x 10(-7) (+/-0.4 x 10(-7)) mm2 at 3.9 microGy on the DX-S. The DX-S has improved image quality compared with a traditional flying spot reader. The separation of the noise sources indicates that the improvements in DQE of the DX-S are due not only to the higher quantum, efficiency and MTF, but also the lower structure, secondary quantum, and excess noise.


Subject(s)
Film Dosimetry/methods , Image Processing, Computer-Assisted/methods , Radiography/methods , Algorithms , Artifacts , Humans , Models, Statistical , Models, Theoretical , Phosphorus/chemistry , Quantum Theory , Scattering, Radiation , Sensitivity and Specificity , Software , X-Rays
18.
Med Phys ; 34(6): 2113-8, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17654914

ABSTRACT

INTRODUCTION AND PURPOSE: Conventional x-ray films and radiochromic films have inherent challenges for high precision radiotherapy dosimetry. Here we have investigated basic characteristics of optically stimulated luminescence (OSL) of irradiated films containing carbon-doped aluminum oxide (Al2O3:C) for dosimetry in therapeutic photon and electron beams. MATERIALS AND METHODS: The OSL films consist of a polystyrene sheet, with a top layer of a mixture of single crystals of Al2O3:C, ground into a powder, and a polyester base. The total thickness of the films is 0.3 mm. Measurements have been performed in a water equivalent phantom, using 4, 6, 10, and 18 MV photon beams, and 6-22 MeV electron beams. The studies include assessment of the film response (acquired OSL signal/delivered dose) on delivered dose (linearity), dose rate (1-6 Gy/min), beam quality, field size and depth (6 MV, ranges 4 x 4-30 x 30 cm2, dmax-35 cm). Doses have been derived from ionization chamber measurements. OSL films have also been compared with conventional x-ray and GafChromic films for dosimetry outside the high dose area, with a high proportion of low dose scattered photons. In total, 787 OSL films have been irradiated. RESULTS: Overall, the OSL response for electron beams was 3.6% lower than for photon beams. Differences between the various electron beam energies were not significant. The 6 and 18 MV photon beams differed in response by 4%. No response dependencies on dose rate were observed. For the 6 MV beam, the field size and depth dependencies of the OSL response were within +/-2.5%. The observed inter-film response variation for films irradiated with the same dose varied from 1% to 3.2% (1 SD), depending on the measurement day. At a depth of 20 cm, 5 cm outside the 20 x 20 cm2 6 and 18 MV beams, an over response of 17% was observed. In contrast to GafChromic and conventional x-ray films, the response of the Al2O3:C films is linear in the clinically relevant dose range 0-200 cGy. CONCLUSIONS: Measurement of the OSL signal of irradiated films containing Al2O3:C is a promising technique for film dosimetry in radiotherapy with no or small response variations with dose rate, beam quality, field size and depth, and a linear response from 0 to 200 cGy.


Subject(s)
Aluminum Oxide/chemistry , Aluminum Oxide/radiation effects , Film Dosimetry/instrumentation , Luminescent Measurements/instrumentation , Optics and Photonics/instrumentation , Radiotherapy Planning, Computer-Assisted/instrumentation , Radiotherapy/instrumentation , Carbon/chemistry , Carbon/radiation effects , Dose-Response Relationship, Radiation , Equipment Design , Equipment Failure Analysis , Film Dosimetry/methods , Materials Testing , Radiation Dosage , Radiotherapy Planning, Computer-Assisted/methods
19.
Med Phys ; 33(12): 4515-26, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17278803

ABSTRACT

The dosimetric properties of a novel intracavitary mold applicator for 192Ir high dose rate (HDR) endorectal cancer treatment have been investigated using Monte Carlo (MC) simulations and experimental methods. The 28 cm long applicator has a flexible structure made of silicone rubber for easy passage into cavities with deep-seated tumors. It consists of eight source catheters arranged around a central cavity for shielding insertion, and is compatible for use with an endocavitary balloon. A phase space model of the HDR source has been validated for dose calculations using the GEANT4 MC code. GAFCHROMIC EBT model film was used to measure dose distributions in water around shielded and unshielded applicators with two loading configurations, and to quantify the shielding effect of a balloon injected with an iodine solution (300 mg I/mL). The film calibration procedure was performed in water using an 192Ir HDR source. Ionization chamber measurements in a Lucite phantom show that placing a tungsten rod in the applicator attenuates the dose in the shielded region by up to 85%. Inserting the shielded applicator into a water-filled balloon pushes the neighboring tissues away from the radiation source, and the resulting geometric displacement reduces the dose by up to 53%; another 8% dose reduction can be achieved when the balloon is injected with an iodine solution. All experimental results agree with the GEANT4 calculations within measurement uncertainties.


Subject(s)
Brachytherapy/instrumentation , Brachytherapy/methods , Film Dosimetry/methods , Iridium Radioisotopes/therapeutic use , Radiometry/methods , Rectal Neoplasms/radiotherapy , X-Ray Film , Calibration , Humans , Iodine/chemistry , Ions , Models, Statistical , Models, Theoretical , Monte Carlo Method , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Silicones/chemistry
20.
Photochem Photobiol ; 81(6): 1331-42, 2005.
Article in English | MEDLINE | ID: mdl-16354111

ABSTRACT

To assist standardization of procedures, facilitate comparisons, and help guide research efforts to optimally inform development of appropriately targeted interventions, there is a need to review methods used to quantify child and adolescent solar ultraviolet radiation (UV) exposure, related outdoor activities and sun-protective practices. This holistic approach is essential for comprehensive research that will provide all-inclusive, informative and meaningful messages for preventive measures of harmful UV exposure. Two databases were searched and 29 studies were retrieved, and these studies report measurement or assessment techniques documenting UV exposure patterns and related outdoor activities. Polysulfone film badges were the main measurement instrument used in 10 studies, with questionnaire, survey data, observation, a model, electronic dosimeters, biological dosimeters, colorimeter and UV colouring labels used in the remaining studies. Methods used to record activities included self-report, parental report, a logbook and observation. Measurement duration and unit of UV exposure varied in most studies, but a method common to 15 studies was measured UV exposure as a percentage of ambient UV. The studies reviewed do not provide sufficient information for the development and evaluation of targeted youth sun protection programs. Studies are required which document precise UV exposure, concurrent activities and sun protection usage for children and adolescents.


Subject(s)
Health Knowledge, Attitudes, Practice , Skin Neoplasms/prevention & control , Sunlight , Ultraviolet Rays , Adolescent , Age Factors , Child , Film Dosimetry , Humans , Radiation Dosage , Research Design , Skin Neoplasms/etiology , Sunlight/adverse effects , Time Factors , Ultraviolet Rays/adverse effects