1.
Cardiol J ; 29(4): 680-690, 2022.
Article in English | MEDLINE | ID: mdl-35621090

ABSTRACT

BACKGROUND: Papillary muscle rupture (PMR) is an infrequent but catastrophic complication after myocardial infarction (MI). Surgical procedure is considered the optimal treatment, despite high risk. However, the gold standard technique is still a major dilemma. Therefore, a meta-analysis was carried out to assess and provide an overview comparing mitral valve replacement (MVR) and mitral valve repair (MVr) for PMR post-MI. METHODS: A systematic literature search was performed. Data were extracted and verified using a standardized data extraction form. Meta-analysis was realized mainly using RevMan 5.4 software. RESULTS: From four observational studies 1640 patients were identified; 81% underwent MVR and 19% MVr. Operative mortality results were significantly higher in MVR group than the MVr group. MVR was performed under emergency conditions and patients admitted in cardiogenic shock or who required the use of mechanical cardiac support underwent MVR. MVr had shorter time of hospitalization and similar incidence of postoperative complications than MVR. No significant differences existed between the two procedures regarding cardiopulmonary bypass time. CONCLUSIONS: Mitral valve repair appears to be a viable alternative to MVR for post-MI PMR, given that it has lower operative mortality, shorter time of hospitalization and similar incidence of short-term postoperative complications than MVR. However, it needs to be pointed out that MVR was associated with the most critical clinical condition following PMR. There is uncertainty regarding the overall survival and improvement of the quality of life between the procedures. Nevertheless, further completed investigation is required.


Subject(s)
Heart Valve Diseases , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Myocardial Infarction , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Myocardial Infarction/complications , Papillary Muscles/diagnostic imaging , Papillary Muscles/surgery , Postoperative Complications/surgery , Quality of Life , Retrospective Studies , Treatment Outcome
2.
Expert Rev Cardiovasc Ther ; 19(9): 787-800, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34348555

ABSTRACT

INTRODUCTION: Mitral annulus calcification (MAC) is a chronic, non-inflammatory, degenerative mechanism of the fibrous base of the mitral valve. While MAC was originally thought to be an age-related degenerative process, there is evidence that other mechanisms, such as atherosclerosis and abnormal calcium phosphorus metabolism, also contribute to the development of MAC. AREAS COVERED: This paper summarizes, existing perception of clinically valid definition of MAC and the pathophysiological processes that lead to the development of MAC and the diagnostic implications of this disease entity. EXPERT OPINION: Minimal evidence exists on the natural history and progression of MAC. Characterization of MAC progression and identification of predisposing risk factors can help to validate hypotheses. MAC is most commonly asymptomatic and incidental finding. Echocardiography is the primary imaging modality for identification and characterization of MAC and associated mitral valve (MV) disease. For patients with an indication for MV surgery, computed tomography (CT) is a complementary imaging modality for MAC. MAC is generally recognized by its characteristic density, location, and shape on echocardiography and CT, unusual variants are sometimes confused with other lesions.


Subject(s)
Calcinosis , Heart Valve Diseases , Calcinosis/diagnostic imaging , Echocardiography , Heart Valve Diseases/diagnostic imaging , Humans , Mitral Valve/diagnostic imaging , Risk Factors
4.
J Invasive Cardiol ; 33(4): E314, 2021 04.
Article in English | MEDLINE | ID: mdl-33794480

ABSTRACT

In select patients with severe, eccentric mitral regurgitation, we have observed that the regurgitant jet may entrain blood along the left atrial wall to produce a Chinese yin-yang symbol on color Doppler. This clinical imaging series demonstrates this unique phenomenon in an 81-year-old woman with symptomatic, severe, functional mitral regurgitation secondary to non-ischemic cardiomyopathy who was referred for transcatheter mitral valve repair. The yin-yang symbol resolved on transthoracic echocardiography after placement of 2 MitraClip NTR devices.


Subject(s)
Cardiac Surgical Procedures , Mitral Valve Insufficiency , Aged, 80 and over , Echocardiography , Female , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Yin-Yang
5.
Saudi J Kidney Dis Transpl ; 32(5): 1465-1469, 2021.
Article in English | MEDLINE | ID: mdl-35532719

ABSTRACT

A 55-year-old male patient undergoing hemodialysis (HD) had shortness of breath, New York Heart Association (NYHA) class IIm (moderate limitation of physical activity) due to chronic heart failure. His past medical history was remarkable for chronic heart diseases and severe functional mitral regurgitation (MR), with an ejection fraction of only 33%. The cardiologist considered this severe MR as the cause of his symptom. Due to the multiple comorbidities and low cardiac function, transcatheter mitral valve repair (TMVR) using a MitraClip was selected as an alternative to surgery. TMVR with MitraClip was successfully performed. Postoperatively, the degree of MR decreased from severe to trivial, with an obvious improvement in symptoms to NYHA class I. He was discharged without any postoperative complications. TMVR with MitraClip is an effective nonsurgical treatment for mitral valve disease in HD patients with multiple comorbidities.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Renal Dialysis , Stroke Volume , Treatment Outcome
6.
Herz ; 46(Suppl 1): 54-60, 2021 Apr.
Article in English | MEDLINE | ID: mdl-31773184

ABSTRACT

BACKGROUND: Patients with reduced left ventricular (LV) function undergoing coronary artery bypass graft surgery or/and aortic valve replacement occasionally show severe mitral valve (MV) regurgitation and thus also undergo surgical mitral annuloplasty. Over time, further deterioration of LV function and additional ischemic events cause recurrence of severe MV regurgitation due to the Carpentier IIIb morphology of the MV that is not adequately addressed by the previously implanted annuloplasty ring. METHODS: Seven patients (Society of Thoracic Surgeons score: 7.5 ± 1.5%) with Carpentier type-IIIb recurrent severe MV regurgitation, having undergone prior cardiothoracic surgery (median: 40 months) including mitral annuloplasty, were treated with the MitraClip device. RESULTS: MitraClip implantation resulted in significantly reduced MV regurgitation and improved New York Heart Association functional state, translating into an increased exercise capability and improved cardiac biomarkers. The morphology of the MV was adequately addressed without causing relevant MV stenosis, while the MV annulus area remained unaltered. The procedure was safe with a 30-day mortality rate of 0%. CONCLUSION: MitraClip-in-the-ring is feasible and in principle safe for treating Carpentier type IIIb severe MV regurgitation after surgical MV repair using mitral annuloplasty. MitraClip-in-the-ring resulted in immediate amelioration of clinical symptoms and increased physical exercise capacity.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome
8.
J Am Heart Assoc ; 9(7): e014874, 2020 04 07.
Article in English | MEDLINE | ID: mdl-32248763

ABSTRACT

Background There has been uncertainty regarding the effect of transcatheter mitral valve repair (TMVr) with MitraClip on cardiac surgical practice. Our aim was to examine the impact of the commercial introduction of TMVr to a comprehensive mitral program. Methods and Results We evaluated 875 patients (aged 69±14 years; 58% men) who underwent transcatheter or mitral surgical procedures over a 6-year period at our institution. Main outcomes were changes in surgical procedural volume after TMVr introduction and short-term mortality for surgical and TMVr procedures. The numbers of patients treated with MitraClip, isolated mitral repair, and any mitral surgery were 249, 292, and 626 patients, respectively. Compared with surgery, patients with MitraClip were older (aged 82±8 versus 64±12 years; P<0.001) and had more severe morbidity. Following the introduction of MitraClip, surgical volumes steadily increased to a rate of 10 (95% CI, 3-7) procedures per year for isolated mitral procedures and 17 (95% CI, 13-20) procedures per year for all mitral surgeries. Both MitraClip and surgical volumes increased at the same rate (P=0.42). In-hospital mortality was 3.2% for MitraClip and 2.1% for all mitral surgeries (P=0.33). At 30 days, survival free of all mortality (P=0.17) and freedom from heart failure rehospitalization (P=0.75) were similar for transcatheter and surgical procedures. Conclusions The commercial introduction of TMVr may be associated with growth in cardiac surgery, without detracting from other therapies, and favorable clinical outcomes for all treated mitral regurgitation patients. These findings demonstrate the potential benefits of complementary therapies in the treatment of patients with mitral regurgitation.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Aged , Aged, 80 and over , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/mortality , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Patient Readmission , Postoperative Complications/etiology , Program Evaluation , Prosthesis Design , Recovery of Function , Retrospective Studies , Time Factors , Treatment Outcome
9.
BMC Cardiovasc Disord ; 20(1): 104, 2020 03 03.
Article in English | MEDLINE | ID: mdl-32126966

ABSTRACT

BACKGROUND: Intractable, mechanical hemolytic anemia (IMHA) is a rare catastrophic complication following mitral valve surgery. We analyzed patient characteristics and IMHA management by reoperations after mitral valve surgery. METHODS: We collected medical records from mitral valve patients requiring reoperation due to IMHA. INCLUSION CRITERIA: hemoglobin < 100 g/L; positive hemolysis tests and echocardiography results; and exclusion of other hemolysis causes. RESULTS: Data from 25 IMHA cases included 10 (40%) early onset (1.3 (0.3,3.0) months) and 15 (60%) late onset (120 (24,204) months) cases. Early IMHA etiologies included surgical defects (6, 60%), uncontrolled infection (3, 30%) and Bechet's disease (1, 10%). Late IMHA etiologies included degeneration (13, 87%), new infection (1, 7%) and trauma (1, 7%). There were more mechanical valves (15, 88%) than bio-valves (2, 12%); the main valvular dysfunction was paravalvular leak (16, 64%). IMHA manifestations included jaundice (18, 72%), dark urine (21, 84%), heart failure (16, 64%), acute kidney injury (11, 44%), hepatomegaly (15, 60%), splenomegaly (15, 60%) and pancreatitis (1, 4%). Laboratory results showed decreased hemoglobin (70 ± 14 g/L) and increased bilirubin (72 ± 57 µmol/L), lactate dehydrogenase (2607 ± 2142 IU/L) and creatinine (136 ± 101 µmol/L) levels. Creatinine level negatively correlated with hemoglobin level (B = -3.33, S.E. B = 1.31, Exp(B) = 368.15, P = 0.018). Preoperative medications included iron supplements (20, 80%), erythropoietin (16, 64%) and beta-blocker (22, 88%). Two patients died of cardiac causes before reoperation. The other 23 underwent reoperation with long surgical times (aortic cross clamp 124 ± 50 min, cardiopulmonary bypass 182 ± 69 min) and blood transfusions (red blood cells 6 (6, 8) units, plasma 600 (400,800) ml, platelet 1(0,2) units). Postoperative complications included cardiac dysfunction (5, 22%), arrhythmia (10, 43%), sepsis (6, 26%), pulmonary infection (5, 22%), gastrointestinal bleeding (3, 13%), cerebral hemorrhage (2, 9%), chronic renal dysfunction (1, 4%) and surgical hemorrhage (1, 4%). Five (33%) patients died after reoperation from cardiac dysfunction (3, 60%), septic shock (1, 20%) and self-discharge (1, 20%). CONCLUSIONS: IMHA induces severe multi-organ dysfunction, contributing to high mortality. Perioperative management should focus on etiological treatment, organ protection, and blood management.


Subject(s)
Anemia, Hemolytic/etiology , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/adverse effects , Hemolysis , Mitral Valve/surgery , Adult , Aged , Anemia, Hemolytic/diagnosis , Anemia, Hemolytic/mortality , Anemia, Hemolytic/surgery , Beijing , Biomarkers/blood , Bioprosthesis , Female , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/mortality , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Hemoglobins/metabolism , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Reoperation , Risk Factors , Time Factors , Treatment Outcome
10.
Pesqui. vet. bras ; Pesqui. vet. bras;40(3): 188-196, Mar. 2020. tab, ilus
Article in English | VETINDEX, LILACS | ID: biblio-1135608

ABSTRACT

The present study evaluated the volume and function of the left atrium by two-dimensional echocardiographic feature-tracking imaging (2D-FTI) and Simpson's monoplanar modeling in dogs with asymptomatic degenerative mitral valve disease (DMVD). The study consisted of 80 dogs that were divided into the following three groups: Group 1, 21 dogs (A); Group 2, 30 dogs (B1) and Group 3, 29 dogs (B2). The variable strain (contraction phase) was significantly lower in Group 3 than in Group 1 (12.92±4.54 x 16.69±5.74, p=0.014), and significant differences in the contraction strain index (CSI) were observed between all of the groups that were evaluated (1 = 46.82±8.10, 2 = 39.88±8.03, 3 = 35.25±5.64, p<0.0001). The atrial diastolic volume index (AdVi) that was measured by 2D-FTI was significantly higher in Group 3 than in Group 1 (1.31±0.95 x 0.96±0.31, p=0.038), and the atrial cardiac index (ACI) was also higher in Group 3 than in Group 1 (102.38±80.18 x 78.19±33.38, p=0.030). Atrial function was assessed by Simpson's monoplanar method, which demonstrated an increase in the left atrial systolic volume, while the contractile function decreased with an increasing disease severity (Group 1 0.21±0.06; Group 2 0.25±0.06; Group 3 0.32±0.08, p<0.0001). The intraobserver and interobserver assessments showed low to moderate variability; most of the values for the coefficient of variation for the variables that were analysed with each method were below 25%. Thus, DMVD was determined to cause an alteration in atrial function, especially in the contraction phase, and even in asymptomatic animals, and the methods of 2D-FTI echocardiography and Simpson's monoplanar evaluation are sensitive and early methods for the detection of left atrial dysfunction.(AU)


O presente estudo avaliou o volume e a função atrial esquerda obtidos por meio da ecocardiografia bidimensional feature tracking (2D-FTI) e pelo método monoplanar de Simpson em cães saudáveis e cães com DMVD assintomáticos. Foram avaliados 80 cães distribuídos em três grupos: Grupo 1, 21 cães (classe A); Grupo 2, 30 cães (classe B1) e Grupo 3, 29 cães (classe B2). A variável strain (fase de contração) foi significativamente menor no Grupo 3 que no Grupo 1 (12,92±4,54 x 16,69±5,74, p=0,014) e para a variável índice de strain de contração (CSI), houve diferença estatística entre todos os grupos avaliados (1 = 46,82±8,10; 2 = 39,88±8,03; 3 = 35,25±5,64, p<0,0001). O índice de volume diastólico atrial (iVdA) mensurado por meio do 2D-FTI foi significativamente maior no Grupo 3 que no Grupo 1 (1,31±0,95 x 0,96±0,31, p=0,038), assim como para o índice cardíaco atrial (iCA) também foi maior no Grupo 3 (102,38±80,18 x 78,19±33,38, p=0,030). A função atrial avaliada pelo método monoplanar de Simpson demonstrou um aumento do volume atrial esquerdo e do volume sistólico do átrio esquerdo, enquanto que a função contrátil diminuiu com o aumento da gravidade da doença (Grupo 1 0,21±0,06; Grupo 2 0,25±0,06; Grupo 3 0,32±0,08; p<0,0001). A avaliação intraobservador e interobservador, demonstrou variabilidade baixa a moderada, uma vez que a maioria dos valores de coeficiente de variação se concentraram abaixo de 25% para as variáveis analisadas em ambos os métodos. Dessa forma, conclui-se que a DMVD causa alteração na função atrial, principalmente na fase de contração, mesmo em animais assintomáticos e que a ecocardiografia 2D-FTI e o método monoplanar de Simpson são métodos sensíveis e precoces na detecção da disfunção atrial esquerda.(AU)


Subject(s)
Animals , Dogs , Atrial Function, Left , Electrophysiologic Techniques, Cardiac/veterinary , Heart Valve Diseases/veterinary , Mitral Valve/diagnostic imaging , Echocardiography/methods , Echocardiography/veterinary
13.
J Cardiovasc Electrophysiol ; 30(9): 1679-1687, 2019 09.
Article in English | MEDLINE | ID: mdl-31332867

ABSTRACT

BACKGROUND AND OBJECTIVES: Macroreentrant atrial tachycardias often occur following atrial fibrillation ablation, most commonly due to nontransmural lesions in prior ablation lines. Perimitral atrial flutter is one such arrhythmia which requires ablation of the mitral isthmus. Our objectives were to review the literature regarding ablation of the mitral isthmus and to provide our approach for assessment of mitral isthmus block. METHODS: We review anatomical considerations, ablation strategies, and assessment of conduction block across the mitral isthmus, which is subject to several pitfalls. Activation sequence and spatial differential pacing techniques are discussed for assessment of both endocardial and epicardial bidirectional mitral isthmus block. RESULTS: Traditional methods for verifying mitral isthmus block include spatial differential pacing, activation mapping, and identification of double potentials. Up to 70% of cases require additional ablation in the coronary sinus (CS) to achieve transmural block. Interpretation of transmural block is subject to six pitfalls involving pacing output, differentiation of endocardial left atrial recordings from epicardial CS recordings, identification of a slowly conducting gap in the line, and catheter positioning during spatial differential pacing. Interpretation of unipolar electrograms can identify nontransmural lesions. We employ a combined epicardial and endocardial assessment of mitral isthmus block, which involves using a CS catheter for epicardial recording and a duodecapolar Halo catheter positioned around the mitral annulus for endocardial recording. CONCLUSIONS: The assessment of transmural mitral isthmus block can be challenging. Placement of an endocardial mapping catheter around the mitral annulus can provide a precise assessment of conduction across the mitral isthmus.


Subject(s)
Atrial Flutter/surgery , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Mitral Valve/surgery , Pulmonary Veins/surgery , Action Potentials , Atrial Flutter/diagnosis , Atrial Flutter/physiopathology , Catheter Ablation/adverse effects , Electrocardiography , Heart Rate , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Predictive Value of Tests , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Treatment Outcome
14.
Interv Cardiol Clin ; 8(3): 295-300, 2019 07.
Article in English | MEDLINE | ID: mdl-31078185

ABSTRACT

Mitral regurgitation is the most commonly occurring valvular heart disease in developed countries. Transcatheter mitral valve replacement (TMVR) has emerged as a novel potential therapy for patients with severe mitral valve disease who are unsuitable candidates for conventional surgery or transcatheter edge-to-edge mitral repair. TMVR with the Tendyne prosthesis has shown potential at short-term follow-up to be an effective and safe treatment alternative for high-risk patients with severe mitral valve disease.


Subject(s)
Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/instrumentation , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Aged , Aged, 80 and over , Alloys , Cardiac Catheterization/methods , Clinical Trials as Topic , Echocardiography, Transesophageal/methods , Feasibility Studies , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve/anatomy & histology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/pathology , Multimodal Imaging/methods , Non-Randomized Controlled Trials as Topic , Prospective Studies , Prosthesis Design/trends , Quality of Life , Severity of Illness Index , Treatment Outcome , Ventricular Outflow Obstruction/diagnostic imaging , Ventricular Outflow Obstruction/etiology
15.
Nutrients ; 10(4)2018 Mar 21.
Article in English | MEDLINE | ID: mdl-29561783

ABSTRACT

BASIK2 is a prospective, double-blind, randomized placebo-controlled trial investigating the effect of vitamin K2 (menaquinone-7;MK7) on imaging measurements of calcification in the bicuspid aortic valve (BAV) and calcific aortic valve stenosis (CAVS). BAV is associated with early development of CAVS. Pathophysiologic mechanisms are incompletely defined, and the only treatment available is valve replacement upon progression to severe symptomatic stenosis. Matrix Gla protein (MGP) inactivity is suggested to be involved in progression. Being a vitamin K dependent protein, supplementation with MK7 is a pharmacological option for activating MGP and intervening in the progression of CAVS. Forty-four subjects with BAV and mild-moderate CAVS will be included in the study, and baseline 18F-sodiumfluoride (18F-NaF) positron emission tomography (PET)/ magnetic resonance (MR) and computed tomography (CT) assessments will be performed. Thereafter, subjects will be randomized (1:1) to MK7 (360 mcg/day) or placebo. During an 18-month follow-up period, subjects will visit the hospital every 6 months, undergoing a second 18F-NaF PET/MR after 6 months and CT after 6 and 18 months. The primary endpoint is the change in PET/MR 18F-NaF uptake (6 months minus baseline) compared to this delta change in the placebo arm. The main secondary endpoints are changes in calcium score (CT), progression of the left ventricularremodeling response and CAVS severity (echocardiography). We will also examine the association between early calcification activity (PET) and later changes in calcium score (CT).


Subject(s)
Aortic Valve Stenosis/drug therapy , Aortic Valve/pathology , Calcinosis/drug therapy , Fluorine Radioisotopes/administration & dosage , Magnetic Resonance Imaging , Mitral Valve/drug effects , Positron-Emission Tomography , Radiopharmaceuticals/administration & dosage , Sodium Fluoride/administration & dosage , Vitamin K 2/therapeutic use , Vitamins/therapeutic use , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Calcinosis/diagnostic imaging , Clinical Protocols , Double-Blind Method , Humans , Mitral Valve/diagnostic imaging , Netherlands , Predictive Value of Tests , Prospective Studies , Research Design , Severity of Illness Index , Time Factors , Treatment Outcome , Vitamin K 2/adverse effects , Vitamins/adverse effects
17.
J Cardiovasc Electrophysiol ; 29(1): 146-153, 2018 01.
Article in English | MEDLINE | ID: mdl-29059484

ABSTRACT

BACKGROUND: Mitral valve prolapse has been associated with increased risk of ventricular arrhythmias. We aimed to examine whether certain cardiac imaging characteristics are associated with papillary muscle origin of ventricular arrhythmias in these patients. METHODS AND RESULTS: We screened electronic medical records of all patients documented to have mitral valve prolapse on either transthoracic echocardiogram (TTE) or cardiac magnetic resonance imaging (CMR) in our center, who also underwent an electrophysiologic study (EPS) between 2007 and 2016. Anterior and posterior mitral leaflet thickness and prolapsed distance were measured on TTE and late gadolinium enhancement (LGE) was assessed on CMR. Patients were categorized as papillary muscle positive (pap (+)) or negative (pap (-)) using EPS. Eighteen patients were included in this study. Of the 15 patients who underwent TTE, a significantly higher proportion of patients in the pap (+) group had an anterior to posterior leaflet prolapse ratio of >0.45 indicating more symmetric leaflet prolapse. There were no differences in anterior or posterior leaflet thickness or prolapse distance between the groups. Patients in the pap (+) group were more likely to be women. Of the 7 patients who underwent CMR, those who were pap (+) were more likely to have LGE in the region of the papillary muscles than those who were pap (-). CONCLUSION: Female gender, more symmetric bileaflet prolapse on TTE, and the presence of papillary muscle LGE on CMR may be associated with papillary muscle origin of ventricular arrhythmias in patients with mitral valve prolapse.


Subject(s)
Echocardiography , Magnetic Resonance Imaging, Cine , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve/diagnostic imaging , Papillary Muscles/diagnostic imaging , Tachycardia, Ventricular/diagnostic imaging , Adult , Aged , Databases, Factual , Electrocardiography , Electronic Health Records , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged , Mitral Valve/physiopathology , Mitral Valve Prolapse/complications , Mitral Valve Prolapse/physiopathology , Papillary Muscles/physiopathology , Predictive Value of Tests , Retrospective Studies , Risk Factors , Sex Factors , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/physiopathology
18.
Catheter Cardiovasc Interv ; 92(2): E135-E138, 2018 08 01.
Article in English | MEDLINE | ID: mdl-28296026

ABSTRACT

The development of paravalvular leak (PVL) following surgical replacement of an aortic or mitral valve is an uncommon complication with significant morbidity and mortality. Surgical or percutaneous repair of PVL can be technically challenging. We describe the application of intracardiac echocardiography guided 3-dimensional electroanatomic mapping to facilitate PVL closure in a symptomatic patient with a previously placed bioprosthetic mitral valve. © 2017 Wiley Periodicals, Inc.


Subject(s)
Bioprosthesis , Cardiac Catheterization , Echocardiography, Transesophageal , Electrophysiologic Techniques, Cardiac , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Mitral Valve Insufficiency/therapy , Mitral Valve/surgery , Prosthesis Failure , Cardiac Catheterization/instrumentation , Echocardiography, Doppler, Color , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Predictive Value of Tests , Prosthesis Design , Treatment Outcome
19.
Int J Chron Obstruct Pulmon Dis ; 12: 2943-2954, 2017.
Article in English | MEDLINE | ID: mdl-29062231

ABSTRACT

BACKGROUND: Inspiratory muscle training (IMT) using a Threshold® device is commonly used to improve the strength and endurance of inspiratory muscles. However, the effect of IMT, alone or with positive end-expiratory pressure (PEEP), on hemodynamic parameters in patients with chronic obstructive pulmonary disease (COPD) remains unknown. OBJECTIVE: To assess the effects of an overload of inspiratory muscles using IMT fixed at 30% of the maximal inspiratory pressure (MIP), and IMT associated with 5 cmH2O of PEEP (IMT + PEEP), on the echocardiographic parameters in healthy subjects and patients with COPD. METHODS: Twenty patients with COPD (forced expiratory volume in 1 second 53.19±24.71 pred%) and 15 age-matched healthy volunteers were evaluated using spirometry, MIP, the COPD assessment test (CAT), and the modified Medical Research Council (mMRC) dyspnea scale. The E- (fast-filling phase) and A- (atrial contraction phase) waves were evaluated at the tricuspid and mitral valves during inspiration and expiration in the following sequence: at basal conditions, using IMT, and using IMT + PEEP. RESULTS: Patients with COPD had reduced MIPs versus the control group. Ten patients had CAT scores <10 and 12 patients had mMRC scores <2. E-wave values at the mitral valve were significantly decreased with IMT during the inspiratory phase in both groups. These effects were normalized with IMT + PEEP. During the expiratory phase, use of IMT + PEEP normalized the reduction in E-wave values in the COPD group. During inspiration at the tricuspid valve, reduction in E-wave values during IMT was normalized by IMT + PEEP in COPD group. During the expiratory phase, the value of the E-waves was significantly reduced with overload of the inspiratory muscles in both groups, and these effects were normalized with IMT + PEEP. A-waves did not change under any conditions. CONCLUSION: Acute hemodynamic effects induced by overloading of the inspiratory muscles were attenuated and/or reversed by the addition of PEEP in COPD patients.


Subject(s)
Breathing Exercises/methods , Exhalation , Hemodynamics , Lung/physiopathology , Mitral Valve/physiopathology , Positive-Pressure Respiration , Pulmonary Disease, Chronic Obstructive/therapy , Respiratory Muscles/physiopathology , Tricuspid Valve/physiopathology , Aged , Aged, 80 and over , Case-Control Studies , Cross-Sectional Studies , Double-Blind Method , Echocardiography, Doppler , Female , Forced Expiratory Volume , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Muscle Strength , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Disease, Chronic Obstructive/physiopathology , Spirometry , Time Factors , Treatment Outcome , Tricuspid Valve/diagnostic imaging
SELECTION OF CITATIONS