Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
Add more filters

Country/Region as subject
Publication year range
1.
BMC Vet Res ; 18(1): 326, 2022 Aug 30.
Article in English | MEDLINE | ID: mdl-36042514

ABSTRACT

BACKGROUND: Ultrasonography is one of the most important techniques that enable the detection and monitoring of pregnancy. One such study using this technique is the assessment of the hemodynamics of fetal and umbilical blood vessels. However, there is little data on blood flow in the placentomes, which is the basic structural unit of the sheep's placenta. Therefore, the aim of this study was to determine the Doppler parameters in the arterial vessels of the caruncles, cotyledons and the umbilical cord as well as measuring venous flow rates during the entire gestation period of the sheep. Additionally, the usefulness of various other ultrasound parameters in the early diagnosis of pregnancy in sheep was analyzed. RESULTS: Most of the Doppler parameters in umbilical, cotyledonary and caruncular arteries were significantly correlated with the day of pregnancy (p < 0.01). In the early stages of pregnancy, the peak systolic velocity (PSV), regardless of the location of the artery, was significantly lower than that in the later stages of pregnancy (p < 0.01). PSV was also found to be significantly higher in the umbilical artery than in the cotyledonary and caruncular arteries (p < 0.01). Until the 50th day of pregnancy, the end diastolic velocity (EDV) was not found in the umbilical and cotyledonary arteries. EDV was significantly higher in the caruncular arteries than in the cotyledonary and umbilical arteries (p < 0.01). The resistance index (RI) and pulsatility index (PI) in the early stages of pregnancy were found to be significantly higher than that in the later stages of pregnancy (p < 0.01). The RI and PI were significantly lower in the caruncular arteries than in the arteries of the cotyledons and umbilical cord (p < 0.01). In the umbilical vein, all Doppler parameters were observed to be significantly higher than those in the placentomal veins (p < 0.01 or p < 0.05). Using transrectal ultrasound, pregnancy was detected between 20 and 28 days after mating. The ovaries were observed to have corpora lutea, the diameter of which was fairly consistent from the 17th to the 56th day of pregnancy. CONCLUSIONS: It has been demonstrated that both the location of the arterial vessel in the placental-umbilical circulation and the gestational age have a significant impact on hemodynamic parameters. The results also provide new insights about the blood flow in caruncular and cotyledonary arteries, which could contribute to a more holistic understanding of hemodynamic changes in the placentas of sheep. Analyzing haemodynamic parameters in the umbilical and placental veins are preliminary studies in sheep, but it could inspire further research in this field. Furthermore, the research conducted confirms the practicality and convenience of transrectal ultrasonography in the early diagnosis of pregnancy in sheep and also indicates that the identification and imaging of the corpus luteum using B-mode ultrasonography can be a very early and simple method of confirming effective mating in sheep.


Subject(s)
Placenta , Ultrasonography, Prenatal , Animals , Blood Flow Velocity/veterinary , Female , Placenta/diagnostic imaging , Pregnancy , Sheep , Ultrasonography , Ultrasonography, Doppler/veterinary , Ultrasonography, Prenatal/veterinary , Umbilical Arteries/blood supply , Umbilical Arteries/diagnostic imaging , Umbilical Arteries/physiology
2.
J Matern Fetal Neonatal Med ; 33(10): 1631-1637, 2020 05.
Article in English | MEDLINE | ID: mdl-30345864

ABSTRACT

Background: Severe intrauterine growth restriction complicates approximately 0.4% of the pregnancies. It increases the risk of perinatal morbidity and mortality.Subjects and methods: A double blind placebo controlled trial was conducted in Beni Suef University hospitals during 2017. It included 46 pregnant women with severe intrauterine growth restriction. Women were randomly allocated into two groups each included 23 patients. Intervention group received sildenafil citrate 20 mg orally three times a day, in addition to fish oil and zinc supplementation. Control group received tablets similar to sildenafil and the same treatment as intervention group. Primary outcomes included improvement in umbilical and middle cerebral arteries pulsatility indices and abdominal circumference.Results: Umbilical and middle cerebral arteries Doppler indices showed significant difference between groups after intake of sildenafil. Umbilical artery pulsatility index decreased significantly (p value = .001) while middle cerebral artery pulsatility index increased significantly in intervention group (p value0.001). Moreover, abdominal circumference growth velocity improved after two weeks of sildenafil intake (p value = .001).Conclusions: Sildenafil citrate may improve uteroplacental and fetal cerebral perfusion in pregnancies complicated by severe intrauterine growth restriction. It also improves abdominal circumference growth velocity. A wide scale randomized trials are needed for evaluation of neonatal and long term morbidity and mortality outcomes of pregnancies treated by sildenafil citrate.


Subject(s)
Fetal Growth Retardation/drug therapy , Sildenafil Citrate/administration & dosage , Vasodilator Agents/administration & dosage , Administration, Oral , Adult , Birth Weight , Double-Blind Method , Egypt , Female , Fish Oils/therapeutic use , Humans , Infant, Newborn , Middle Cerebral Artery/diagnostic imaging , Middle Cerebral Artery/drug effects , Placenta/blood supply , Placenta/drug effects , Pregnancy , Pulsatile Flow , Sildenafil Citrate/adverse effects , Ultrasonography, Prenatal , Umbilical Arteries/diagnostic imaging , Umbilical Arteries/drug effects , Vasodilator Agents/adverse effects , Zinc/administration & dosage
3.
Ultrasound Obstet Gynecol ; 53(4): 454-464, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30126005

ABSTRACT

OBJECTIVE: To assess studies reporting reference ranges for umbilical artery (UA) and fetal middle cerebral artery (MCA) Doppler indices and cerebroplacental ratio (CPR), using a set of predefined methodological quality criteria for study design, statistical analysis and reporting methods. METHODS: This was a systematic review of observational studies in which the primary aim was to create reference ranges for UA and MCA Doppler indices and CPR in fetuses of singleton gestations. A search for relevant articles was performed in MEDLINE, EMBASE, CINAHL, Web of Science (from inception to 31 December 2016) and references of the retrieved articles. Two authors independently selected studies, assessed the risk of bias and extracted the data. Studies were scored against a predefined set of independently agreed methodological criteria and an overall quality score was assigned to each study. Linear multiple regression analysis assessing the association between quality scores and study characteristics was performed. RESULTS: Thirty-eight studies met the inclusion criteria. The highest potential for bias was noted in the following fields: 'ultrasound quality control measures', in which only two studies demonstrated a comprehensive quality-control strategy; 'number of measurements taken for each Doppler variable', which was apparent in only three studies; 'sonographer experience', in which no study on CPR reported clearly the experience or training of the sonographers, while only three studies on UA Doppler and four on MCA Doppler did; and 'blinding of measurements', in which only one study, on UA Doppler, reported that sonographers were blinded to the measurement recorded during the examination. Sample size estimations were present in only seven studies. No predictors of quality were found on multiple regression analysis. Reference ranges varied significantly with important clinical implications for what is considered normal or abnormal, even when restricting the analysis to the highest scoring studies. CONCLUSIONS: There is considerable methodological heterogeneity in studies reporting reference ranges for UA and MCA Doppler indices and CPR, and the resulting references have important implications for clinical practice. There is a need for the standardization of methodologies for Doppler velocimetry and for the development of reference standards, which can be correctly interpreted and applied in clinical practice. We propose a set of recommendations for this purpose. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Intervalos de referencia para los índices Doppler de la arterias umbilical y cerebral media del feto y la relación cerebroplacentaria: una revisión sistemática OBJETIVO: Evaluar los estudios que informan sobre intervalos de referencia para los índices Doppler y la relación cerebroplacentaria (RCP) de la arteria umbilical (AU) y la arteria cerebral media (ACM) del feto, mediante un conjunto de criterios de calidad metodológica predefinidos para el diseño del estudio, el análisis estadístico y los métodos de notificación. MÉTODOS: Esta fue una revisión sistemática de estudios observacionales en los que el objetivo principal fue crear intervalos de referencia para los índices Doppler de la AU y la ACM y la RCP de fetos de gestaciones con feto único. Se realizó una búsqueda de artículos relevantes en MEDLINE, EMBASE, CINAHL, Web of Science (desde el inicio hasta el 31 de diciembre de 2016) y en las referencias de los artículos recuperados. Dos autores, de forma independiente, seleccionaron los estudios, evaluaron el riesgo de sesgo y extrajeron los datos. Los estudios se calificaron según un conjunto predefinido de criterios metodológicos acordados de forma independiente y se asignó una puntuación de calidad global a cada estudio. Se realizó un análisis de regresión múltiple lineal para evaluar la asociación entre las puntuaciones de calidad y las características del estudio. RESULTADOS: Un total de 38 estudios cumplieron los criterios de inclusión. El mayor potencial de sesgo se observó en los siguientes casos: 'medidas de control de calidad del ultrasonido', donde sólo dos estudios demostraron una estrategia integral de control de calidad; 'número de mediciones tomadas para cada variable Doppler', que solo fue aparente en tres estudios; 'experiencia del ecografista', puesto que ningún estudio sobre la RCP informó claramente sobre la experiencia o la formación de los ecografistas, y tan solo lo hicieron tres estudios sobre el Doppler de la AU y cuatro sobre el Doppler de la ACM; y 'mediciones a ciegas', donde tan sólo un estudio sobre el Doppler de la AU comunicó que los ecografistas no tuvieron acceso a la medición registrada durante el estudio. Las estimaciones del tamaño de la muestra sólo se comunicaron en siete estudios. No se encontraron predictores de calidad en el análisis de regresión múltiple. Los intervalos de referencia variaron significativamente con implicaciones clínicas importantes para lo que se considera normal o anómalo, incluso cuando se restringió el análisis a los estudios con mayor puntuación. CONCLUSIONES: Existe una heterogeneidad metodológica considerable en los estudios que informan sobre los intervalos de referencia para los índices Doppler de la AU y la ACM y la RCP, y las referencias resultantes tienen implicaciones importantes para la práctica clínica. Es necesario estandarizar las metodologías de la velocimetría Doppler y desarrollar estándares de referencia que puedan ser interpretados y aplicados correctamente en la práctica clínica. Se propone una serie de recomendaciones para este fin.


Subject(s)
Middle Cerebral Artery/diagnostic imaging , Predictive Value of Tests , Pulsatile Flow , Ultrasonography, Doppler , Umbilical Arteries/diagnostic imaging , Female , Gestational Age , Humans , Middle Cerebral Artery/embryology , Observational Studies as Topic , Observer Variation , Pregnancy , Reference Values , Ultrasonography, Prenatal
4.
J Perinat Med ; 45(1): 51-55, 2017 Jan 01.
Article in English | MEDLINE | ID: mdl-27387329

ABSTRACT

AIM: Our aim is to evaluate the effect of nifedipine on fetoplacental hemodynamic parameters. METHODS: A retrospective study was conducted at a tertiary center with 30 patients for whom nifedipine treatment was used as a tocolytic therapy for preterm labor. Initiation of this treatment was at 31.6±2.5 weeks of gestation. We combined the pulse Doppler imaging parameters with grayscale imaging via the Bernoulli theorem, which is called the "continuity equation", to get the fetoplacental perfusion (FPP). Evaluated parameters were the resistance index (RI), the pulsatility index (PI), systole/diastole ratios (S/D), the velocity-time integral of the umbilical artery (VTI), the radius of the umbilical artery, the peak systolic velocity and the mean pressure gradient in the umbilical artery. From these parameters, the FPP was acquired. RESULTS: We found that the RI, the PI and the S/D ratio did not change after treatment with nifedipine. The mean pressure gradient, the VTI and the peak systolic velocity increased after treatment with nifedipine. Nifedipine increases FPP from 166±73.81 beat.cm3/min to 220±83.3 beat.cm3/min. DISCUSSION: Although nifedipine had no effect on the PI, the RI or the S/D, it increased the mean pressure gradient, the VTI and FPP.


Subject(s)
Nifedipine/therapeutic use , Placental Circulation/drug effects , Premature Birth/prevention & control , Tocolytic Agents/therapeutic use , Umbilical Arteries/drug effects , Adult , Female , Hemodynamics , Humans , Nifedipine/pharmacology , Pregnancy , Retrospective Studies , Tocolytic Agents/pharmacology , Ultrasonography, Doppler, Pulsed , Ultrasonography, Prenatal , Umbilical Arteries/diagnostic imaging , Young Adult
5.
Am J Obstet Gynecol ; 214(3): 399.e1-8, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26721782

ABSTRACT

BACKGROUND: In 2012, yoga was practiced by 20 million Americans, of whom 82% were women. A recent literature review on prenatal yoga noted a reduction in some pregnancy complications (ie, preterm birth, lumbar pain, and growth restriction) in those who practiced yoga; to date, there is no evidence on fetal response after yoga. OBJECTIVES: We aimed to characterize the acute changes in maternal and fetal response to prenatal yoga exercises using common standardized tests to assess the well-being of the maternal-fetal unit. STUDY DESIGN: We conducted a single, blinded, randomized controlled trial. Uncomplicated pregnancies between 28 0/7 and 36 6/7 weeks with a nonanomalous singleton fetus of women who did not smoke, use narcotics, or have prior experience with yoga were included. A computer-generated simple randomization sequence with a 1:1 allocation ratio was used to randomize participants into the yoga or control group. Women in the yoga group participated in a 1-time, 1 hour yoga class with a certified instructor who taught a predetermined yoga sequence. In the control group, each participant attended a 1-time, 1 hour PowerPoint presentation by an obstetrician on American Congress of Obstetricians and Gynecologists recommendations for exercise, nutrition, and obesity in pregnancy. All participants underwent pre- and postintervention testing, which consisted of umbilical and uterine artery Doppler ultrasound, nonstress testing, a biophysical profile, maternal blood pressure, and maternal heart rate. A board-certified maternal-fetal medicine specialist, at a different tertiary center, interpreted all nonstress tests and biophysical profile data and was blinded to group assignment and pre- or postintervention testing. The primary outcome was a change in umbilical artery Doppler systolic to diastolic ratio. Sample size calculations indicated 19 women per group would be sufficient to detect this difference in Doppler indices (alpha, 0.05; power, 80%). Data were analyzed using a repeated-measures analysis of variance, a χ(2), and a Fisher exact test. A value of P < .05 was considered significant. RESULTS: Of the 52 women randomized, 46 (88%) completed the study. There was no clinically significant change in umbilical artery systolic to diastolic ratio (P = .34), pulsatility index (P = .53), or resistance index (P = .66) between the 2 groups before and after the intervention. Fetal and maternal heart rate, maternal blood pressure, and uterine artery Dopplers remained unchanged over time. When umbilical artery indices were individually compared with gestational age references, there was no difference between those who improved or worsened between the groups. CONCLUSION: There was no significant change in fetal blood flow acutely after performing yoga for the first time in pregnancy. Yoga can be recommended for low-risk women to begin during pregnancy.


Subject(s)
Fetus/physiology , Umbilical Arteries/physiology , Uterine Artery/physiology , Yoga , Adult , Blood Pressure , Female , Heart Rate, Fetal , Humans , Movement , Pregnancy , Prenatal Care , Pulsatile Flow , Single-Blind Method , Ultrasonography, Doppler , Umbilical Arteries/diagnostic imaging , Uterine Artery/diagnostic imaging , Vascular Resistance , Young Adult
6.
Clin Exp Obstet Gynecol ; 40(1): 113-5, 2013.
Article in English | MEDLINE | ID: mdl-23724522

ABSTRACT

AIM: The relation between biophysical profile (BPP), cerebroplacental (C/P) ratio, and lecithin/sphingomyelin (L/S) ratio as a predictor perinatal outcome in term intrauterine growth restricted (IUGR) neonates was evaluated. MATERIALS AND METHODS: A retrospective study of the perinatal outcome of 77 term monofetal pregnancies complicated with IUGR fetuses (< 10 percentile) who were terminated by cesarean section in 2010 was performed at the Institute of Gynecology and Obstetrics, Belgrade. RESULTS: The most frequent early neonatal complication was asphyxia. The authors found a strong correlation between the L/S ratio and birth weight (BW) r = 0.609, as well as between BPP and Apgar score 5 r = 0.583. Significant negative correlation was found between asphyxia and BPP r = -0.398, as well as between asphyxia and C/P ratio r = -0.379. CONCLUSION: In serous IUGR neonates, low values of BPP and L/S ratios predicted asphyxia.


Subject(s)
Asphyxia Neonatorum/diagnostic imaging , Fetal Growth Retardation/diagnostic imaging , Respiratory Distress Syndrome, Newborn/diagnostic imaging , Adult , Asphyxia Neonatorum/metabolism , Female , Fetal Growth Retardation/metabolism , Humans , Infant, Newborn , Lecithins/metabolism , Middle Cerebral Artery/diagnostic imaging , Placenta/diagnostic imaging , Predictive Value of Tests , Pregnancy , Respiratory Distress Syndrome, Newborn/metabolism , Retrospective Studies , Sphingomyelins/metabolism , Ultrasonography, Prenatal , Umbilical Arteries/diagnostic imaging , Vascular Resistance , Young Adult
7.
Neonatal Netw ; 32(1): 5-15, 2013.
Article in English | MEDLINE | ID: mdl-23318202

ABSTRACT

Infants exposed to absent or reversed end-diastolic flow (ARE DF) in utero may be at an increased risk of developing necrotizing enterocolitis (NEC). This article reviews placental function and the development of ARE DF. Studies examining the relationship between AREDF and NEC are reviewed, yet research remains inconclusive regarding this relationship. Recent studies reveal that early minimal enteral feeding does not increase the incidence of NEC in infants with AREDF. Initiation and advancement of enteral feedings should be monitored closely in this subset of the neonatal intensive care unit (NICU) population.


Subject(s)
Enteral Nutrition/methods , Enterocolitis, Necrotizing , Infant, Premature, Diseases , Nutrition Therapy/methods , Umbilical Arteries , Clinical Trials as Topic , Enterocolitis, Necrotizing/diagnosis , Enterocolitis, Necrotizing/etiology , Enterocolitis, Necrotizing/physiopathology , Female , Humans , Infant, Newborn , Infant, Premature , Infant, Premature, Diseases/diagnosis , Infant, Premature, Diseases/etiology , Infant, Premature, Diseases/physiopathology , Intensive Care, Neonatal/methods , Monitoring, Physiologic , Placenta Diseases/diagnosis , Placenta Diseases/physiopathology , Placental Circulation , Pregnancy , Risk Factors , Ultrasonography, Doppler, Color/methods , Umbilical Arteries/diagnostic imaging , Umbilical Arteries/physiopathology
8.
Ginekol Pol ; 83(11): 865-70, 2012 Nov.
Article in Polish | MEDLINE | ID: mdl-23379198

ABSTRACT

Twin Reversed Arterial Perfusion (TRAP) sequence complicates about 1% of all monochorionic twin pregnancies and about 1 to 35000 of all pregnancies. It involves an acardiac twin whose structural defects are incompatible with life, and an otherwise normal "pump" co-twin. As the blood flow in the acardiac twin is reversed, it keeps on growing owing to the oxygenated blood from the co-twin. Here we report a case of monochorionic, diamniotic twin pregnancy after ICS/-ET complicated with TRAP sequence, diagnosed at 11 weeks of pregnancy The unusual finding in this case was the residual heart in the so called acardiac twin. Gradually the normal twin developed signs of hemodynamic compromise. Reversed a-wave in ductus venosus was observed. The acardiac twin showed subcutaneous oedema. On 24 November 2011 a successful interstitial ultrasound-guided laser coagulation was performed at 16 weeks of gestation. 17G needle and 0.6 mm laser fibre were used. The needle was introduced into the pelvic region of the acardiac twin through the abdominal wall. A series of laser bursts lasting 5-10 seconds were fired, until cessation of blood flow in the pelvic vessels and umbilical cord of the acardiac twin was confirmed using colour Doppler. The course of the intervention was uneventful. Routine steroid therapy was administered at 27 weeks of gestation. At 32 weeks the patient was hospitalized and oral antibiotics were administered due to premature rupture of the membranes and suspicion of intrauterine growth retardation of the pump twin. The patient delivered spontaneously at completed 33 weeks of pregnancy (weight 1805g, Apgar 10). After the delivery a stage 2 intraventricular hemorrhage and jaundice were observed in the neonate. Phototherapy was administered and the mother and the child were eventually discharged from the hospital, both in good general condition. Since then, two more successful interstitial laser coagulations in TRAP sequence were performed in our institution. The essence of the treatment of TRAP sequence is cessation of the blood flow from the pump to the acardiac twin. Fetoscopic cord ligature or coagulation, and laser or radiofreqency ablations of the acardiac twin vessels, are the possible methods of intervention. The interstitial laser coagulation of the acardiac twin is less invasive than fetoscopic umbilical cord coagulation, as the outer diameter of the 17G needle is much smaller. A meticulous comparison of these methods would require a randomised study but at 16 weeks of MCDA twin pregnancy interstitial laser coagulation seems to be the method of choice. The outcome of the procedure and possible treatment options in case of TRAP together with the review of literature, are presented in the article.


Subject(s)
Abnormalities, Multiple/surgery , Diseases in Twins/surgery , Fetofetal Transfusion/surgery , Laser Coagulation/methods , Pregnancy Reduction, Multifetal/methods , Pregnancy, Multiple , Umbilical Arteries/surgery , Adult , Arteriovenous Fistula/surgery , Birth Weight , Female , Fetal Heart/abnormalities , Humans , Minimally Invasive Surgical Procedures/methods , Placenta/blood supply , Pregnancy , Pregnancy Outcome , Treatment Outcome , Ultrasonography , Umbilical Arteries/diagnostic imaging , Umbilical Cord/surgery
9.
Nutr Metab Cardiovasc Dis ; 21(1): 54-61, 2011 Jan.
Article in English | MEDLINE | ID: mdl-19819678

ABSTRACT

BACKGROUND AND AIMS: Periconception folic acid supplementation may influence early placentation processes and thereby the occurrence of hypertensive pregnancy disorders. For this reason we examined the associations between periconception folic acid supplementation and uteroplacental vascular resistance, blood pressure, and the risks of gestational hypertension and preeclampsia, in 5993 pregnant women, participating in a population-based cohort study. METHODS AND RESULTS: Folic acid supplementation was assessed by questionnaire. Mean pulsatility index (PI) and resistance index (RI) of the uterine (UtA) and umbilical arteries (UmA) were measured by Doppler ultrasound in mid- and late pregnancy. Systolic and diastolic blood pressures (SBP, DBP) were measured in early, mid- and late pregnancy. Compared to women who did not use folic acid, preconception folic acid users had a slightly lower UtA-RI in mid-pregnancy [ß -0.02, 95% confidence interval (CI) -0.03, -0.01] and late pregnancy [ß -0.02, 95% CI -0.03, -0.001], a lower UtA-PI in mid-pregnancy [ß -0.06, 95% CI -0.1, -0.03] and late pregnancy [ß -0.03, 95% CI -0.05, -0.01], as well as tendencies towards a lower UmA-PI in mid-pregnancy [ß -0.02, 95% CI -0.04, -0.001] and late pregnancy [ß -0.01, 95% CI -0.02, 0.01]. Additionally, these women had slightly higher SBP and DBP throughout pregnancy. Neither the patterns of blood-pressure change during pregnancy, nor the risk of gestational hypertension and preeclampsia differed between the folic acid categories. CONCLUSION: Periconception folic acid supplementation is associated with lower uteroplacental vascular resistance and higher blood pressures during pregnancy. The effects are small and within physiologic ranges and seem not associated with the risk of hypertensive pregnancy disorders.


Subject(s)
Folic Acid/pharmacology , Placental Circulation/drug effects , Vascular Resistance/drug effects , Vitamins/pharmacology , Adolescent , Adult , Blood Pressure/drug effects , Cohort Studies , Dietary Supplements , Female , Gestational Age , Humans , Hypertension, Pregnancy-Induced/epidemiology , Hypertension, Pregnancy-Induced/physiopathology , Pre-Eclampsia/epidemiology , Pregnancy , Pregnancy Trimesters , Socioeconomic Factors , Ultrasonography , Umbilical Arteries/diagnostic imaging , Umbilical Arteries/physiopathology , Young Adult
11.
Basic Clin Pharmacol Toxicol ; 99(2): 146-52, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16918716

ABSTRACT

Estimation of the influence of oral supplementation with low dose of L-arginine on biophysical profile, foeto-placental circulation and neonatal outcome in preeclampsia. Randomized, placebo-controlled, double-blind, clinical trial. Oral therapy with 3 g of L-arginine daily or placebo as a supplement to standard therapy. Eighty-three preeclamptic women, randomly assigned to the L-arginine (n=42) or placebo (n=41) groups; [n=30 (L-arginine) and n=31 (placebo) ended the study, respectively]. Foetal gain chances due to ultrasound biometry, biophysical profile, Doppler velocimetry of pulsatility indices of umbilical and middle cerebral arteries, cerebro-placental ratio, as well as differences in duration of pregnancy and clinical data of newborn. L-arginine treatment transitory accelerated foetal gain and improved biophysical profile. Starting from 3rd week of therapy, the umbilical artery pulsatility indices values were significantly lower in L-arginine than in placebo group. Moreover, treatment with L-arginine caused significant increase of middle cerebral artery pulsatility indices and cerebro-placental ratio values. Latency was longer in L-arginine group. Neonates delivered in the L-arginine group revealed higher Apgar score. Supplementary treatment with oral L-arginine seems to be promising in improving foetal well-being and neonatal outcome as well as in prolonging pregnancy complicated with preeclampsia. However, these benefits require confirmation in more-powered, larger studies.


Subject(s)
Arginine/therapeutic use , Birth Weight/drug effects , Fetal Development/drug effects , Pre-Eclampsia/physiopathology , Administration, Oral , Adult , Arginine/administration & dosage , Cesarean Section/statistics & numerical data , Dose-Response Relationship, Drug , Double-Blind Method , Female , Fetal Development/physiology , Fetal Monitoring/methods , Fetal Weight/drug effects , Humans , Infant, Newborn , Middle Cerebral Artery/diagnostic imaging , Middle Cerebral Artery/drug effects , Middle Cerebral Artery/physiology , Natural Childbirth/statistics & numerical data , Pregnancy , Pregnancy Trimester, First , Pulsatile Flow/drug effects , Pulsatile Flow/physiology , Ultrasonography, Prenatal/methods , Umbilical Arteries/diagnostic imaging , Umbilical Arteries/drug effects , Umbilical Arteries/physiology
12.
Ultrasound Obstet Gynecol ; 27(4): 403-8, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16565996

ABSTRACT

OBJECTIVE: To assess the effect of nifedipine tocolysis on Doppler parameters of the uterine, umbilical and fetal middle cerebral arteries and atrioventricular valves in the first 48 h of therapy. METHODS: Doppler waveforms of uterine, umbilical and middle cerebral arteries and both atrioventricular valves were measured from 28 pregnant women and fetuses prior to and during nifedipine therapy for preterm labor. Maternal and fetal heart rates (FHR), maternal systolic and diastolic blood pressure, and the Doppler pulsatility index (PI) of the uterine, umbilical and middle cerebral arteries were measured. The cerebroplacental ratio (middle cerebral artery PI/umbilical artery PI) was calculated. The total time velocity integrals (TVIs) of tricuspid and mitral valves and their E- and A-wave peak velocity ratio (E/A) were measured. Friedman repeated-measures analysis of variance was used to compare the variables before and after nifedipine therapy. If significant differences were found, Wilcoxon's signed ranks test was used to analyze the difference between the two variables. A P-value of < 0.05 was considered significant. RESULTS: Nifedipine maintenance was associated with a significant decline in maternal systolic and diastolic blood pressure after 24 h, while maternal heart rate and FHR were unaffected. The uterine artery PI had decreased significantly at 24 and 48 h, while the umbilical artery PI did not change significantly. The middle cerebral artery PI had decreased significantly at 24 and again at 48 h. A significant fall in the cerebroplacental Doppler ratio was maintained beyond 24 h. The mean E/A values, TVIs and TVI x FHR values at 24 and 48 h were unchanged from the baseline values. CONCLUSIONS: Nifedipine maintenance tocolysis is associated with a significant decline in uterine artery and middle cerebral artery Doppler indices 24 h after the first dose. Fetal cardiac diastolic function is unaffected and the significant redistribution observed after 24 h is likely to be attributable to altered cerebral blood flow.


Subject(s)
Nifedipine/therapeutic use , Obstetric Labor, Premature/prevention & control , Tocolytic Agents/therapeutic use , Ultrasonography, Prenatal/methods , Umbilical Arteries/drug effects , Adult , Analysis of Variance , Arteries/drug effects , Blood Pressure/drug effects , Diastole , Female , Heart Rate/drug effects , Heart Valves/diagnostic imaging , Heart Valves/drug effects , Heart Valves/embryology , Humans , Middle Cerebral Artery/diagnostic imaging , Middle Cerebral Artery/drug effects , Middle Cerebral Artery/embryology , Obstetric Labor, Premature/diagnostic imaging , Pregnancy , Pregnancy Trimester, Third , Pulsatile Flow/drug effects , Time Factors , Ultrasonography, Doppler , Umbilical Arteries/diagnostic imaging , Uterus/blood supply , Uterus/diagnostic imaging , Uterus/drug effects
13.
J Indian Med Assoc ; 103(1): 12-4, 16-7, 2005 Jan.
Article in English | MEDLINE | ID: mdl-16008324

ABSTRACT

To study the efficacy of yoga on the outcome of complicated pregnancy, 121 women attending antenatal clinic at Gunasheela Surgical and Maternity Hospital (GSMH) in Bangalore, India, were enrolled between 18-20 weeks of pregnancy in a prospective, matched, observational study. Sixty-eight women were in the yoga group and 53 women in the control group. Women were matched for age, gravida and Doppler velocimetry scores of umbilical and uterine arteries. Yoga practices including physical postures, breathing and meditation were practised by the yoga group, one hour daily, from the date of entry into the study until delivery. The control group walked half an hour twice a day during the study period. Compliance in both the groups was ensured. In babies the birth-weight is significantly higher (P < 0.018) in the Yoga group (2.78 +/- 0.52 kg), compared to the control group (2.55 +/- 0.52 kg). Occurrence of complications of pregnancy (pregnancy-induced hypertension, intrauterine growth retardation, pre-term delivery) shows lower trends in yoga group.


Subject(s)
Pregnancy Complications/therapy , Yoga , Adolescent , Adult , Female , Humans , Pregnancy , Pregnancy Complications/diagnostic imaging , Pregnancy Complications/psychology , Pregnancy Outcome , Prospective Studies , Stress, Psychological/prevention & control , Ultrasonography, Prenatal , Umbilical Arteries/diagnostic imaging , Uterus/blood supply , Yoga/psychology
14.
Ultrasound Obstet Gynecol ; 24(7): 761-5, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15505816

ABSTRACT

OBJECTIVE: To evaluate the effect of nifedipine on placental and fetal middle cerebral and atrioventricular Doppler waveforms. METHODS: Doppler waveforms of uterine (UtA), umbilical (UA) and middle cerebral (MCA) arteries and both atrioventricular valves were measured from 21 pregnant women/fetuses prior to and during nifedipine therapy for preterm labor. Maternal and fetal heart rates (FHR), maternal systolic and diastolic blood pressure, the Doppler pulsatility index and systolic/diastolic ratio of the UtA, UA and MCA were measured. The total time velocity integrals (TVI) of tricuspid and mitral valves and their E-wave/A-wave (E/A) TVI ratios were measured. Wilcoxon signed pairs test was used to compare the differences in Doppler parameters before and at 3 h after nifedipine loading up to a maximum dose of 40 mg. RESULTS: Fetal arterial and UtA Doppler parameters were not different before and after nifedipine therapy. Blood flow across the atrioventricular valves and the TVI were equally unaffected by nifedipine. The TVI x FHR product was also unchanged following nifedipine therapy. CONCLUSIONS: In women with otherwise uncomplicated pregnancies, nifedipine loading and tocolysis are generally well tolerated by the mother. Placental and fetal cerebral arterial blood flow, fetal systolic and diastolic cardiac function and downstream distribution of fetal cardiac output are unaffected by nifedipine loading. These results apply to women with unchanged vital parameters. Further studies are necessary to show long-term effects of nifedipine therapy and may help to refine choice of tocolytic agents.


Subject(s)
Nifedipine/therapeutic use , Obstetric Labor, Premature/diagnostic imaging , Obstetric Labor, Premature/prevention & control , Tocolytic Agents/therapeutic use , Ultrasonography, Doppler , Ultrasonography, Prenatal , Adult , Cerebral Arteries/diagnostic imaging , Echocardiography, Doppler , Female , Humans , Placenta/diagnostic imaging , Pregnancy , Pregnancy Trimester, Third , Regional Blood Flow , Statistics, Nonparametric , Umbilical Arteries/diagnostic imaging
15.
Asia Oceania J Obstet Gynaecol ; 18(2): 187-93, 1992 Jun.
Article in English | MEDLINE | ID: mdl-1503542

ABSTRACT

In a study of 45 hypertensive pregnant women, the systolic velocity/diastolic velocity ratio and pulsatility index of the umbilical and uterine arteries showed good correlation with the maternal blood pressure, and they appeared to provide a good parameter for the fetoplacental condition. Using the pulse Doppler method, we studied the effects of the antihypertensive agent nifedipine and of dipyridamole (an agent used to treat proteinuria) on the blood flow of the umbilical and uterine arteries in 16 hypertensive pregnant women. The results proved that both drugs caused a decrease in the vascular resistance of the umbilical artery and suggested that they increased the blood flow volume of this artery and were useful in the treatment of hypertension during pregnancy.


Subject(s)
Dipyridamole/therapeutic use , Hypertension/drug therapy , Nifedipine/therapeutic use , Pregnancy Complications, Cardiovascular/drug therapy , Ultrasonography, Prenatal , Umbilical Arteries/diagnostic imaging , Uterus/blood supply , Adult , Arteries/diagnostic imaging , Arteries/physiopathology , Blood Flow Velocity , Female , Humans , Hypertension/diagnostic imaging , Hypertension/physiopathology , Pregnancy , Pregnancy Complications, Cardiovascular/diagnostic imaging , Pregnancy Complications, Cardiovascular/physiopathology , Pregnancy Outcome , Umbilical Arteries/physiopathology
16.
Clin Perinatol ; 19(2): 437-48, 1992 Jun.
Article in English | MEDLINE | ID: mdl-1617886

ABSTRACT

Over the past two decades, obstetric and neonatal health care has shifted its attention to the preterm pregnancy. Due to the immaturity of the fetal autonomic nervous system, the usual diagnostic criteria for intervention in the preterm fetus are not available. Alternative methods such as the biophysical profile and Doppler offer the clinician a reasonable alternative in identifying potential fetal compromise.


Subject(s)
Fetal Monitoring/standards , Obstetric Labor, Premature/prevention & control , Acoustic Stimulation , Amniotic Fluid/chemistry , Biophysical Phenomena , Biophysics , Blood Flow Velocity , Clinical Protocols/standards , Decision Trees , Female , Fetal Monitoring/methods , Gestational Age , Humans , Obstetric Labor, Premature/diagnosis , Obstetric Labor, Premature/epidemiology , Physical Stimulation , Pregnancy , Ultrasonography, Prenatal , Umbilical Arteries/diagnostic imaging , Vibration
17.
Am J Obstet Gynecol ; 163(6 Pt 1): 1844-8, 1990 Dec.
Article in English | MEDLINE | ID: mdl-2256493

ABSTRACT

Twenty patients with preeclampsia at a gestational age of 26 to 35 weeks were treated with oral nifedipine until delivery. The mean oral daily dose was 45.1 +/- 11 mg/day (range, 40 to 80 mg/day). Fetal aorta, internal carotid artery, umbilical artery, and uteroplacental Doppler flow velocity waveforms were recorded before treatment and then serially. The mean nifedipine concentration at the time of the Doppler studies was 60.3 ng/ml (range, 10 to 90 ng/ml). The use of nifedipine therapy was associated with a significant decrease in both maternal systolic blood pressure (baseline, 154 to 135 mm Hg, p less than 0.001) and diastolic blood pressure (baseline, 100 to 88 mm Hg, p less than 0.001). However, there was no significant difference in the resistance index between baseline and postnifedipine Doppler studies in either the fetal or uteroplacental vessels. The use of oral nifedipine to control blood pressure in preeclampsia does not affect the resistance indices in fetal or uteroplacental vessels as measured by the Doppler technique.


Subject(s)
Fetus/drug effects , Nifedipine/therapeutic use , Placenta/drug effects , Pre-Eclampsia/drug therapy , Administration, Oral , Adolescent , Adult , Aorta/diagnostic imaging , Aorta/drug effects , Aorta/physiology , Blood Pressure/drug effects , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/drug effects , Carotid Artery, Internal/physiology , Female , Fetus/physiology , Humans , Nifedipine/administration & dosage , Placenta/blood supply , Placenta/diagnostic imaging , Pre-Eclampsia/physiopathology , Pregnancy , Pregnancy Outcome , Pregnancy Trimester, Second , Pregnancy Trimester, Third , Ultrasonography, Prenatal , Umbilical Arteries/diagnostic imaging , Umbilical Arteries/drug effects , Umbilical Arteries/physiopathology , Vascular Resistance/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL